Skip to main content
Log in

Improved Doppler ultrasonic monitoring of the foetal heart rate

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The Doppler ultrasonic technique for the monitoring of the foetus has been available for well over a decade. It offers a noninvasive assessment of the condition of the foetus and has therefore become an important antenatal technique. However, the foetal heart rate information obtained by this technique is considered to be less precise than that obtained from the foetal e.c.g. The waveforms recorded by the Doppler ultrasonic method are complex and variable and this often leads to difficulty in identifying a reliable and regular measuring point within these waveforms from which to calculate the heart rate. This has resulted in a cautious acceptance of ultrasonically determined foetal heart-rate records. This paper does not dispute the difficulties of interpreting such rate information, but outlines a pair of algorithms for processing and presenting a more accurate and reliable indication of the foetal heart rate determined from the Doppler ultrasonic method. These algorithms calculate a two second average rate from only those intervals which have been determined to be ‘valid’, based on the criterion that they should be within ±10% of the most previous valid interval.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Hon, E. H., (1975) An introduction to foetal heart rate monitoring (2nd ed.) Copyright by Prof.E. H. Hon, University of Southern California School of Medicine, Los Angeles, USA.

    Google Scholar 

  • Mantell, C. D. (1976) Atlas of foetal monitoring. National Women's Hospital, Auckland, NZ.

    Google Scholar 

  • O'Keeffe, D. F. andFreeman, R. K. (1979) A survey of foetal monitoring equipment.Contemporary Ob./Gyn.,14, special issue, 25–27.

    Google Scholar 

  • Shenker, L. (1966) Review: foetal electrocardiography.Obstetrical & Gynaecology Survey,21, 367–388.

    Google Scholar 

  • Wells, P. N. T. (1972)Ultrasonics in clinical diagnosis. Churchill Livingstone, Edinburgh and London, UK.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tuck, D.L. Improved Doppler ultrasonic monitoring of the foetal heart rate. Med. Biol. Eng. Comput. 19, 135–140 (1981). https://doi.org/10.1007/BF02442706

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442706

Keywords

Navigation