A new method of testing the visual field in children has been developed on a standard IBM personal computer AT with enhanced graphics display (EGA) using software written in Basic. Conventional perimetric methods are usually imposible to perform in children because they are long and tedious and unlikely to maintain the child's attention for their duration. They also require an immobile eye, which is impractical in children. In contrast to current methods, the test allows the subject's eye to move in an effort to achieve improved fixation and uses the guise of a game to hold the child's attention. Preliminary studies show that the test achieves these objectives and offers the possibility of self-examination without constant skilled supervision. The relatively low cost of the system should enable visual field examination to become more widely available than it is at present.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Accornero, N. (1984). Computerised video screen perimetry.Arch. Ophthalmol.,102, 40–41.

    Google Scholar 

  • Fausset, T. M. (1986). A rapid technique for kinetic visual field determination in young children and adults with central retinal lesions.Doc. Ophthalmol. Proc., Series 49, 495–501.

    Google Scholar 

  • Frisen, L. (1986) A computer graphics visual screener using high pass spatial frequency resolution targets and multiple feedback devices.Ibid., Doc. Ophthalmol. Proc., Series 49, 441–446.

    Google Scholar 

  • Harrington, D. O. (1981)The visual fields: a textbook and atlas of clinical perimetry. C. V. Mosby Co., New York.

    Google Scholar 

  • Holmin, C. (1979) Variability of glaucomatous visual field defects in computerised perimetry.Arch. Klin. Exp. Ophthalmol.,210, 235–250.

    Google Scholar 

  • Keltner, J. L. (1983). Screening for Visual Field Abnormalities with Automated Perimetry.Surv. Ophthalmol.,28, (3), 175–182.

    Article  Google Scholar 

  • Schulzer, M. andMikelberg, F. S. (1987) A study of the value of the central and peripheral visual isoptres in assessing visual field progression in the presence of paracentral scotoma measurements.Br. J. Ophthalmol.,71, 422–427.

    Google Scholar 

  • Weber, H. andDobek, K. (1986) What is the most suitable grid for computer perimetry in glaucoma patients?Ophthalmol.,192, 88–96.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Johnston, S.C., Damato, B.E., Evans, A.L. et al. Computerised visual field test for children using multiple moving fixation targets. Med. Biol. Eng. Comput. 27, 612–616 (1989). https://doi.org/10.1007/BF02441643

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441643

Keywords

Navigation