Intracranial pressure monitoring by means of a passive radiosonde

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The system described is based on the employment of a radiosonde energised from the outside in such a way that it will not be subject to the limitations arising from the use of batteries. The main sources of error, consisting in the thermal drift of the electronic components and particularly of the pressure transducer, have been eliminated by transmitting to the outside the information regarding temperature. Thus the data concerning the pressure can be corrected after reception by a simple manual calculation or by automatic computing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Atkinson, J. R., Shurtleff, D. B. andFoltz, E. L. (1967) Radiotelemetry for the measurement of intracranial pressure.J. Neurosurg. 27, 428–432.

    Google Scholar 

  • Beks, J. W. F., Bosch, D. A. andBrock, M. (Eds.) (1976)Intracranial pressure III, Springer-Verlag, Berlin.

    Google Scholar 

  • Brazzoduro, G. andMacellari, V. (1974) Realizzazione di un prototipo di radiosonda per la misura della pressione del fluido cerebrospinale.Ann. Ist. Super. Sanità 10, 268–274.

    Google Scholar 

  • Brock, M. andDiefenthaler, K. (1972) A modified equipment for the continuous telemetric monitoring of epidural or subdural pressure. InIntracranial pressure, Springer-Verlag, Berlin, 21–26.

    Google Scholar 

  • Brock, M. andDietz, H. (Eds.) (1972)Intracranial pressure, Springer-Verlag, Berlin.

    Google Scholar 

  • Cohadon, F., La Balme, M., Castel, J. P. andVandendriessche (1974) ICP microprobes series microfet.Intracranial pressure II, Springer-Verlag, Berlin, 375–376.

    Google Scholar 

  • Coroneos, N. J., McDowall, D. G., Gibson, R. M., Pickerodt, V. W. A. andKeaney, N. P. (1973) Measurement of extradural pressure and its relationship to other intracranial pressuresJ. Neurol. Neurosurg. Psychiat. 36, 514–522.

    Article  Google Scholar 

  • De Rougement, J., Benabid, A. L. andBarge, M. (1974) Intracranial pressure measurement by epidural technique—A simple solution. InIntracranial pressure II, Springer-Verlag, Berlin, 384–385.

    Google Scholar 

  • Dorsch, N. W. C. andSymon, L. (1974) The validity of extradural measurement of the intracranial pressure. InIntracranial pressure II, Springer-Verlag, Berlin, 403–408.

    Google Scholar 

  • Foroglou, G., Zander, E., Faure, R. andBesse, R. (1974) Telemetric measurement of intracranial pressure with an electromagnetic detector. InIntracranial pressure II, Springer-Verlag, Berlin, 377.

    Google Scholar 

  • Handa, H., Yoneda, S., Matsuda, M. andHanda, J. (1974) A miniature transducer for continuous monitoring of intracranial pressure. InIntracranial pressure II, Springer-Verlag, Berlin, 378–380

    Google Scholar 

  • Harper, C. A. (Ed.) (1970)Handbook of material and processes for electronics, MacGraw-Hill, New York, 1–35.

    Google Scholar 

  • Jacobson, S. A. andRothballer, A. B. (1966) Prolonged measurement of experimental intracranial pressure using a subminiature absolute pressure transducer.J. Neurosurg. 25, 603–608.

    Google Scholar 

  • Lundberg, N., Ponten, U. andBrock, M. (Eds.) (1975)Intracranial pressure II, Springer-Verlag, Berlin.

    Google Scholar 

  • Mackay, S. R. (1970)Bio-medical telemetry, Wiley, New York, 101.

    Google Scholar 

  • Majors, R., Schettini, A., Mahig, J. andNevis, A. H. (1972) Intracranial pressure measured with the coplanar pressure transducer.Med. & Biol. Eng. 10, 724–733.

    Google Scholar 

  • Numoto, M., Wallman, J. K. andDonaghy, R. M. P. (1973) Pressure indicating bag for monitoring intracranial pressure.J. Neurosurg. 39, 784–787.

    Google Scholar 

  • Schettini, A., McKay, L., Majors, R., Mahig, J. andNevis, A. H. (1971) Experimental approach for monitoring surface brain pressure.34, 38–47.

    Article  Google Scholar 

  • Sundbärg, G. andNoines, H. (1972) Simultaneous recording of the epidural and ventricular fluid pressure. InIntracranial pressure, Springer-Verlag, Berlin, 46–50.

    Google Scholar 

  • Turner, J. M., Gibson, R. M., McDowall, D. G. andNahhas, F. (1974) Further experiences with extradural pressure monitoring. InIntracranial pressure II, Springer-Verlag, Berlin, 397–402.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Barbaro, V., Macellari, V. Intracranial pressure monitoring by means of a passive radiosonde. Med. Biol. Eng. Comput. 17, 81–86 (1979). https://doi.org/10.1007/BF02440957

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02440957

Keywords

Navigation