Analysis of recirculation in single-needle haemodialysis

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

An analysis of recirculation in single-needle dialysis was performedin vitro. The percentage of recirculation was determined both as a function of fistula flow and of pulsatile arterial outflow, using water and blood as test liquids and using a single-head pump as well as a double-head pump. The most important factors responsible for recirculation were found to be (a) poor fistula flow compared with arterial outflow, (b) dead space and mixing in the needle and y-connectors and (c) compliance of the bloodlines in the dialyser circuit. It is concluded that an efficient, short, single-needle dialysis is not possible for patients with poor fistula flow. For other patients, the percentage of recirculation can be minimised by using a double-head pump and a compliant dialyser.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Hilderson, J., Waeleghem, J. P. van, Egmond, J. van, Haelst, J. P. van, Schelstraete, K. andRingoir, S. (1974) Single needle vs. double needle dialysis.Dialysis and Transplantation 10–19, 65.

    Google Scholar 

  • Keshaviah, P., Carlson, G. andWathen, R. (1976)In vitro and clinical evaluation of single needle dialysis.Trans. Amer. Soc. Artif. Int. Organs,221, 367–376.

    Google Scholar 

  • Kopp, K. F., Gutch, C. F. andKolff, W. J. (1972) Single needle dialysis.Trans. Amer. Soc. Artif. Int. Organs 18, 75–81.

    Google Scholar 

  • Martin, T. R. P., Harston, G., Segasby, C. A. andBlack, M. M. (1978) Factors affecting blood flow during single needle dialysis.J. Med. Eng. Techn. 2, 7–11.

    Article  Google Scholar 

  • Piron, M., Becaus, I., Lameire, N., Bleyn, J. andRingoir, S. (1978) Anin vitro study of recirculation in single needle dialysis with the double headpump.In Frost, T. H. (Ed.)Technical aspects of renal dialysis. Pitman Medical, Tunbridge Wells, England.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Meijer, J.H., Reulen, J.P.H., Schneider, H. et al. Analysis of recirculation in single-needle haemodialysis. Med. Biol. Eng. Comput. 17, 578–582 (1979). https://doi.org/10.1007/BF02440902

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02440902

Keywords

Navigation