Skip to main content
Log in

Computer controlled voltage clamp experiments

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

A small digital computer (a Digital Equip. Corp. LINC-8) has been interfaced to voltage clamp control circuitry and a buffer memory in order for it to both control experiments and provide fast and flexible data acquisition. The experiments are designed and run from the computer graphic terminal in a conversational language, offering the experimenter programmed control over input voltage-time patterns and the rate of data sampling. Because many records are usually required and biological preparations tend to deteriorate with time, automated experiment control and faster data acquisition and storage provides more dependable data than manual methods. Subsequent analysis is much more convenient when the data has been stored along with parameters values and labels in a standard format on a digital bulk storage device such as a magnetic tape or disk.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cole, K. S. Dynamic electrical characteristics of the squid axon membrane.des Archives des Sciences Physiologiques 1949,3, 253–258.

    CAS  Google Scholar 

  • Hille, B. The selective inhibition of delayed potassium currents in nerve by tetraethylammonium ion.J. Gen. Physiol. 1967,50, 1287.

    Article  CAS  PubMed  Google Scholar 

  • Hodgkin, A. L., Huxley, A. F., andB. Katz Measurement of current-voltage relations in the membrane of the giant axon ofLoligo.J Physiol. 1952,116, 424–448.

    CAS  PubMed  Google Scholar 

  • Moore, J. W. andCole, K. S., Voltage Clamp Techniques. InPhysical Techniques in Biological Research, 6, p. 263. New York: Academic Press, 1963.

    Google Scholar 

  • Moore, J. W. andGebhart, J. H. Stabilized wide-band potentiometric preamplifiers.Proc. I.R.E. 1962,50, 1928–1941.

    Google Scholar 

  • Moore, J. W. andHarris, E. M. Voltage Clamp Data Processing. In D. Agin (Ed.),Perspectives in Membrane Biophysics. London: Gordon and Breach Science Publishers Ltd. 1972.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Joyner, R.W., Moore, J.W. Computer controlled voltage clamp experiments. Ann Biomed Eng 1, 368–380 (1973). https://doi.org/10.1007/BF02407676

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02407676

Keywords

Navigation