Abstract
The goal of this research was to find a practical means by which an array of 100 needle-shaped electrodes could be implanted into the cerebral cortex with minimal brain tissue trauma. It was found that insertion of these structures into cortical tissues could only be performed using high insertion speeds. A pneumatically actuated impact insertion system has been developed that is capable of inserting an electrode array into feline brain tissue at speeds from about 1 to 11 m/s. We found that a minimum array insertion speed of 8.3 m/s was necessary for a complete, safe insertion of all 100 electrodes in the array to a depth of 1.5 mm into feline cortex. The performance of the impact insertion system is discussed in terms of a simplified representation of cortical tissue.
Similar content being viewed by others
References
Brindley, G.S.; Lewin, W.S. The sensations produced by electrical stimulation of the visual cortex. J. Physiol. 196:479–493; 1968.
Campbell, P.K.; Jones, K.E.; Huber, R.J.; Horch, K.A.; Normann, R.A. A silicon-based three dimensional-neural interface: Manufacturing processes for an intracortical electrode array. IEEE Trans. Biomed. Eng. 38(8):758–768; 1991.
Cha, K. Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system. Ann. Biomed. Eng. 20:439–449; 1992.
Edell, D.J.; McNeil, V.M.; Clark, L.D. Microfabrication technology for development of chronic neural information transducers. Proc. Ann. Int. Conf. IEEE-Int. Elect. Dev. Meet.; 1986: pp. 180–183.
Fung, Y.C. Biomechanics — Mechanical properties of living tissues. New York, NY: Springer-Verlag; 1981.
Hibdon, D.T. High frequency motion to reduce catheter insertion resistance. Salt Lake City: Department of Bioengineering, University of Utah; 1988. Master's Thesis.
Hubel, D.H. Eye, brain and vision. Scientific American library. New York, NY: W.H. Freeman and Company; 1988: pp. 93–125.
Jones, K.E.; Campbell, P.K.; Normann, R.A. A glass/silicon composite intracortical electrode array. Ann. Biomed. Eng. 20:423–437; 1992.
Koeneman, J.B. Viscoelastic properties of brain tissue. Case Institute of Technology, Cleveland, OH; 1966. Master's Thesis.
Normann, R.A. A penetrating cortical electrode array design considerations. Proc. Ann. Int. Conf. IEEE-Systems, Man and Cybern.; 1990: pp. 921–923.
Ommaya, A.K. Mechanical properties of tissues of the nervous system. J. Biomech. 1:127–138; 1968.
Ranck, J.B. Electrical stimulation research techniques. New York, NY: Academic Press; 1981: pp. 1–36.
Rousche, P.J.; Normann, R.A. A system for impact insertion of a 100 electrode array into cortical tissue. Proc. Ann. Int. Conf. IEEE Eng. Med Biol. Soc.; 1990: 12:494–495.
Wise, K.D.; Angell, J.B. A low-capacitance multielectrode probe for use in extracellular neurophysiology. IEEE Trans. Biomed. Eng. BME-22(3):212–219; 1975.
Wuerker, R.B.; Palay, S.L. Neurofilaments and microtubules in anterior horn cells of the rat. Tissue and Cell. 1:387–402; 1969.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rousche, P.J., Normann, R.A. A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Ann Biomed Eng 20, 413–422 (1992). https://doi.org/10.1007/BF02368133
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF02368133