Skip to main content
Log in

A method for pneumatically inserting an array of penetrating electrodes into cortical tissue

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

The goal of this research was to find a practical means by which an array of 100 needle-shaped electrodes could be implanted into the cerebral cortex with minimal brain tissue trauma. It was found that insertion of these structures into cortical tissues could only be performed using high insertion speeds. A pneumatically actuated impact insertion system has been developed that is capable of inserting an electrode array into feline brain tissue at speeds from about 1 to 11 m/s. We found that a minimum array insertion speed of 8.3 m/s was necessary for a complete, safe insertion of all 100 electrodes in the array to a depth of 1.5 mm into feline cortex. The performance of the impact insertion system is discussed in terms of a simplified representation of cortical tissue.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Brindley, G.S.; Lewin, W.S. The sensations produced by electrical stimulation of the visual cortex. J. Physiol. 196:479–493; 1968.

    CAS  PubMed  Google Scholar 

  2. Campbell, P.K.; Jones, K.E.; Huber, R.J.; Horch, K.A.; Normann, R.A. A silicon-based three dimensional-neural interface: Manufacturing processes for an intracortical electrode array. IEEE Trans. Biomed. Eng. 38(8):758–768; 1991.

    Article  CAS  PubMed  Google Scholar 

  3. Cha, K. Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system. Ann. Biomed. Eng. 20:439–449; 1992.

    CAS  PubMed  Google Scholar 

  4. Edell, D.J.; McNeil, V.M.; Clark, L.D. Microfabrication technology for development of chronic neural information transducers. Proc. Ann. Int. Conf. IEEE-Int. Elect. Dev. Meet.; 1986: pp. 180–183.

  5. Fung, Y.C. Biomechanics — Mechanical properties of living tissues. New York, NY: Springer-Verlag; 1981.

    Google Scholar 

  6. Hibdon, D.T. High frequency motion to reduce catheter insertion resistance. Salt Lake City: Department of Bioengineering, University of Utah; 1988. Master's Thesis.

    Google Scholar 

  7. Hubel, D.H. Eye, brain and vision. Scientific American library. New York, NY: W.H. Freeman and Company; 1988: pp. 93–125.

    Google Scholar 

  8. Jones, K.E.; Campbell, P.K.; Normann, R.A. A glass/silicon composite intracortical electrode array. Ann. Biomed. Eng. 20:423–437; 1992.

    CAS  PubMed  Google Scholar 

  9. Koeneman, J.B. Viscoelastic properties of brain tissue. Case Institute of Technology, Cleveland, OH; 1966. Master's Thesis.

  10. Normann, R.A. A penetrating cortical electrode array design considerations. Proc. Ann. Int. Conf. IEEE-Systems, Man and Cybern.; 1990: pp. 921–923.

  11. Ommaya, A.K. Mechanical properties of tissues of the nervous system. J. Biomech. 1:127–138; 1968.

    Article  CAS  PubMed  Google Scholar 

  12. Ranck, J.B. Electrical stimulation research techniques. New York, NY: Academic Press; 1981: pp. 1–36.

    Google Scholar 

  13. Rousche, P.J.; Normann, R.A. A system for impact insertion of a 100 electrode array into cortical tissue. Proc. Ann. Int. Conf. IEEE Eng. Med Biol. Soc.; 1990: 12:494–495.

    Google Scholar 

  14. Wise, K.D.; Angell, J.B. A low-capacitance multielectrode probe for use in extracellular neurophysiology. IEEE Trans. Biomed. Eng. BME-22(3):212–219; 1975.

    CAS  Google Scholar 

  15. Wuerker, R.B.; Palay, S.L. Neurofilaments and microtubules in anterior horn cells of the rat. Tissue and Cell. 1:387–402; 1969.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rousche, P.J., Normann, R.A. A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Ann Biomed Eng 20, 413–422 (1992). https://doi.org/10.1007/BF02368133

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02368133

Keywords

Navigation