Skip to main content
Log in

A microcomputer based automated, quantitative coronary angiographic analysis system

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Rapid and accurate assessment of coronary artery stenotic severity is important in therapy and understanding of coronary artery disease. Since automated systems minimize prejudiceand variations in analysis, we developed an automated, quantitative coronary analysis system utilizing an IBM PC-XT computer. Film images (35 mm) were cine-to-video converted and subsequently digitized by an IBM PC-XT computer. Given an approximate center line, the computer automatically detected edges, corrected for X-ray magnification, and calculated arterial dimensions. On objects of known dimensional sizes, the correlation coefficient between actual and calculated dimensions was 0.996 (p<0.01) with a standard error of estimate of 0.07 mm and ±3.0% reproducibility. For objects less than 1 mm in diameter, the standard error of estimate was 0.05 mm with ±4.1% reproducibility. However, with minimal contrast material (25%), the standard error of estimate increased to 0.20 mm with ±7.2% reproducibility. The results indicate that automated, quantitative coronary angiography can be achieved using an inexpensive IBM PC-XT based system, provided that the vessels are adequately opacified.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Brown, B.G.; Bolson, E.; Frimer, M.; Dodge, H.T. Quantitative coronary arteriography. Estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation 55:329–337; 1977.

    CAS  PubMed  Google Scholar 

  2. Harrison, D.G.; White, C.W.; Hiratzka, L.F.; Doty, D.B.; Barnes, D.H.; Eastham, C.L.; Marcus, M.L. The value of lesion cross-sectional area determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending coronary arterial stenoses. Circulation 69:1111–1119; 1984a.

    CAS  PubMed  Google Scholar 

  3. Harrison, D.G.; Ferguson, D.W.; Collins, S.M.; Skorton, D.J.; Ericksen, E.E.; Kioschos, J.M.; Marcus, M.L.; White, C.W. Rethrombosis after reperfusion with streptokinase: Importance of geometry of residual lesions. Circulation 69:991–999; 1984b.

    CAS  PubMed  Google Scholar 

  4. Mancini, G.B.J.; Simon, S.B.; McGillen, M.J.; LeFree, M.T.; Friedman, H.Z.; Vogel, R.A. Automated quantitative coronary angiography: Morphologic and physiologic validation in vivo of a rapid digital angiographic method. Circulation 75:452–460; 1987.

    CAS  PubMed  Google Scholar 

  5. Marble, A.E.; McIntyre, C.M.; Hastings-James, R.; Hor, C.W. A comparison of digital algorithms used in computing the derivative of left ventricular pressure. IEEE Transactions Biomed Engr BME 28:524–528; 1981.

    CAS  Google Scholar 

  6. Owen, R.M.; Dewey, J.D.; Bove, A.A. Evaluation of dimensions and steady-state hydraulic properties of coronary arteries. Biomed Sci Inst 19:43–46; 1983.

    CAS  Google Scholar 

  7. Reiber, J.H.C.; Serruys, P.W.; Kooijman, C.J.; Wijns, W.; Slager, C.J.; Gerbrands, J.J.; Schuurbiers, J.C.H.; Boer, A.D.; Hugenholtz, P.G.. Assessment of short, medium, and long term variations in arterial dimensions from computer assisted quantitation of coronary cine-angiograms. Circulation 71:280–288; 1985.

    CAS  PubMed  Google Scholar 

  8. Reiber, J.H.C.; Kooijman, C.J.; Slager, C.J.; Gerbrands, J.J.; Schuurbiers, J.C.H.; den Boer, A.; Wijns, W.; Serruys, P.W.; Hugenholtz, P.G. Coronary artery dimensions from cineangiograms: Methodology and validation of a computer-assisted analysis procedure. IEEE Trans Med Imaging M1-3:131–141; 1984.

    Google Scholar 

  9. Spears, J.R.; Sandor, T.; Als, A.V.; Malagold, M.; Markis, J.E.; Grossman, W.; Serur, J.R.; Paulin, S. Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. Circulation 68:453–461; 1983.

    CAS  PubMed  Google Scholar 

  10. White, C.W.; Wright, C.B.; Doty, D.B.; Hiratzka, L.F.; Eastham, C.L.; Harrison, D.G.; Marcus, M.L. Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? N Engl J. Med 310:819–324; 1984.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This study was supported in part by NIH Grant Number HL 36051. Dr. Little is an established investigator of the American Heart Association.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Santamore, W.P., Kahl, F.R., Kutcher, M.A. et al. A microcomputer based automated, quantitative coronary angiographic analysis system. Annals of Biomedical Engineering 16, 367–377 (1988). https://doi.org/10.1007/BF02364624

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02364624

Keywords

Navigation