Abstract

Silver/silver chloride (Ag/AgCl) electrodes possess excellent electrical properties for measuring the electrical activity of gastrointestinal smooth muscle but exert toxic effects on this tissue in vitro. We thus developed a platinum electrode for use in vitro, the construction of these electrodes relying upon the formation of a glass-platinum/iridium seal. The platinum/iridium (Pt/Ir) electrodes were platinized using a current density of 0.45 mA mm−2. The electrode impedance at 0.01 Hz showed a minimum with platinization current-time products greater than 500 mA s mm−2. However, deposits in excess of 600 mA s mm−2 were readily removed by mechanical abrasion and proved unsatisfactory. Optimal platinization was obtained with a deposit of platinum-black corresponding to a current-time product of 550 mA s mm−2. Optimally-platinized electrodes (geometric surface area 0.11 mm2) had a stable and reproducible potential with a drift of less than 1 μV min−1 and a lower impedance than optimally chlorided silver electrodes (geometric surface area 0.46 mm2) at frequencies higher than 0.25 Hz. The platinized Pt/Ir electrodes were used to record the electrical activity of gastrointestinal smooth muscle in vitro.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Becker, J.M., W.M. Duff, F.G. Moody. Myoelectric control of gastrointestinal and biliary motility: a review.Surgery 89:466–477, 1981.

    CAS  PubMed  Google Scholar 

  2. Cole, K.S. and U. Kishimoto. Platinized silver chloride electrode.Science 136:381–382, 1962.

    CAS  PubMed  Google Scholar 

  3. Daniel, E.E.. Electrical activity of the gastrointestinal tract as an indication of mechanical activity.Am. J. Dig. Dis. 8:54–102, 1963.

    Article  CAS  PubMed  Google Scholar 

  4. de Boer, R.W. and van Oosterom. Electrical properties of platinum electrodes: impedance measurements and time-domain analysis.Med. & Biol. Eng. & Comput. 16:1–10, 1978.

    Google Scholar 

  5. El-Sharkawy, T.Y. Electrical activities of the muscle layers of the canine colon.J. Physiol. 342:67–83, 1983.

    CAS  PubMed  Google Scholar 

  6. Fisher, G., R.G. Sayre, R.G. Bickford. Histological changes in cat's brain after introduction of metallic and coated wire used in electroencephalography.Proc. Mayo Clic. 32:14–21, 1957.

    Google Scholar 

  7. Gill, R.C., K.R. Cote, K.L. Bowes, Y.J. Kingma. Human colonic smooth muscle: electrical and contractile activity in vitro.Gut 27:293–299, 1986.

    CAS  PubMed  Google Scholar 

  8. Hinder, R.A. and K.A. Kelly. Human gastric pacesetter potential. Site of origin, spread and response to gastric transection and proximal gastric vagotomy.Am. J. Surg. 133:29–33, 1977.

    Article  CAS  PubMed  Google Scholar 

  9. Jackson, W.F. and B.R. Tuling Toxic effects of silver/silver chloride electrodes on vascular smooth muscle.Circ. Res. 53:105–108, 1983.

    CAS  PubMed  Google Scholar 

  10. Jones, G. and G.M. Bollinger. The measurement of the conductance of electrolytes. VII on platinization.J. Am. Chem. Soc. 57:280–284, 1935.

    CAS  Google Scholar 

  11. Kingma, Y.J., J. Lenhart, N.G. Durdle, K.L. Bowes, M.M. Chambers. Improved Ag/AgCl pressure electrodes.Med. & Biol. Eng. & Comput. 21:351–357, 1983.

    CAS  Google Scholar 

  12. Kohlrausch, F. Uber platinirte Elektroden und Widerstandsbestimmung.Ann. Phys. Chem. 60:315–332, 1897.

    Google Scholar 

  13. Lukanov, J. and P. Atmadjov. Investigating the effect of silver ions on the contractile function of smooth-muscle preparation from guinea pig stomach in vitro.Folia Med. (Plovdiv) 21:11–19, 1979.

    CAS  Google Scholar 

  14. Onaral, B. and H.P. Schwan. Linear and onlinear properties of platinum electrode polarization. Part 1: frequency dependence at very low frequencies.Med. & Biol. Eng. & Comput. 20:299–306, 1982.

    CAS  Google Scholar 

  15. Petering, H.G. Pharmacology and toxicology of heavy metals: Silver.Pharmacol. Ther. 1:127–130, 1976.

    CAS  Google Scholar 

  16. Ray, C.D. and A.E. Walker. Platinized platinum wire brain depth probes: a comparison with electrodes of stainless steel.Proc. Am. EEG Soc. 19:90–91, 1965.

    Google Scholar 

  17. Schwan, H.P. Determination of biological impedances. In: Physical Techniques in Biological Research, Vol. 6. Nastuk, W.L. (Ed.), New York: Academic Press, 323–407, 1963.

    Google Scholar 

  18. Schwan, H.P. Electrode polarization impedance and measurement in biological materials.Ann. N.Y. Acad. Sci. 148:191–209, 1968.

    CAS  PubMed  Google Scholar 

  19. Warburg, E. Ueber das Verhalten sogenanten und polisierbarer Electroden gegen Wechselstrom.Ann. Phy. Chem. 67:493–499, 1899.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cote, K.R., Gill, R.C. Development of a platinized platinum/iridium electrode for use in vitro. Ann Biomed Eng 15, 419–426 (1987). https://doi.org/10.1007/BF02363562

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02363562

Keywords

Navigation