Abstract
The errors occurred when α, the parameter that accounts for the non-ideal behavior of the epithermal flux, are neglected, have been evaluated for the determination of twenty elements in biological materials, using. gold and sodium comparators, and zirconium to measure the thermal to epithermal flux ratio (f). Sodium allows the determination of 15 elements, and up to 18 elements can be determined in positions relatively well thermalized by the simultaneous use of gold and sodium comparators, in all the cases with errors ≦2%, when α is not considered. Results obtained for reference materials are presented.
Similar content being viewed by others
References
F. de Corte, J. Hoste, Isotopenpraxis, 25 (1989) No. 7, 269.
F. de Corte, L. Moens, S. Jovanovic, A. Simonits, A. de Wispelaere, J. Radioanal. Nucl. chem., 102 (1986) 37.
S. Jovanovic, F. De Corte, A. Simonits, L. Moens, P. Vikotic, R. Zejnilovic, J. Hoste, Proc. 1st Balkan Conference on Activation Analysis, 1985, p. 19.
P. Bode, M. Blaauw, I. Obrusnik, J. Radioanal. Nucl. Chem., 157 (1992) 301.
G. Erdtmann, Errors of Absolute Methods of Reactor Neutron Activation Analysis Caused by Non-1/E Epithermal Neutron Spectra. The Influence of the Error of α when Using the Zirconium Double Monitor Method. Forschungzentrum Jülich GmbH, KFA, Zentralabteilung für Chemische Analysen.
Kögdahl, in: Radiochemical Methods of Analysis, Vol. 1, IAEA, Vienna (1965) 23.
F. De Corte, Thek 0 -Standardization Method, a Move to the Optimization of Neutron Activation Analysis, Rijksuniversiteil, Gent, 1987.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Montoya, E.H.R., Cohen, I.M., Hidalgo, P.M. et al. The corrections for non-ideal behavior of the epithermal neutron spectrum and the restitution of the simplicity in parametric activation analysis. J Radioanal Nucl Chem 240, 475–479 (1999). https://doi.org/10.1007/BF02349399
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02349399