Abstract
Laser Doppler perfusion imaging (LDI) is currently used in a variety of clinical applications, however, LDI instruments produce images of low resolution and have long scan times. A new optical perfusion imager using a laser speckle measurement technique and its use for in vivo blood flow measurements are described. Measurements of human skin and surgically exposed rabbit tissue made using this instrument were compared with a commercial laser Doppler perfusion imaging instrument. Results from blood flow measurements showed that the laser speckle imager measured an 11–67% decrease in blood flow under arterial occlusion. Under similar conditions, the laser Doppler imager measured blood flow decreases of 21–63%. In comparison with LDI, it was observed that the higher temporal resolution of the laser speckle imager was more sensitive to measuring the hyperaemic response immediately following occlusion. This in vivo study demonstrated some of the several advantages laser speckle imaging has over conventional LDI, making the new instrument more versatile in a clinical environment.
Similar content being viewed by others
References
Arildsson, M. L., Wardell, K., andNilsson, G. E. (1997): ‘Higher order moment processing of laser Doppler perfusion signals’,J. Biomed. Opt.,2, pp. 358–363
Bonner, R., andNossal, R. (1981): ‘Model for laser Doppler measurements of blood flow in tissue’,Appl. Opt.,20, pp. 2097–2107
Bray, R., Forrester, K., Mcdougall, J. J., Damji, A., andFerrell, W. R. (1996): ‘Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits’,Med. Biol. Eng. Comput.,34, pp. 227–231
Briers, J. D., andWebster, S. (1995): ‘Quasi real-time digital version of single-exposure speckle photography for full-field monitoring of velocity or flow fields’,Opt. Comm.,116, pp. 36–42
Briers, J. D. (1996): ‘Laser Doppler and time varying speckle: a reconciliation’,J. Opt. Soc. Am. A,13, pp. 345–350
Briers, J. D., Richards, G. R., andHe, X. W. (1999): ‘Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)’,J. Biomed. Opt.,4, pp. 164–175
Challoner, A. V. J. (1979): ‘Photoelectric plethysmography for estimating cutaneous blood flow’ inRolfe, P. (Ed.): ‘Non-invasive physiological measurements’, Vol. 1 (Academic Press, London), pp. 125–151
Dougherty, G. (1994): ‘Spectra analysis of laser Doppler signals in real time using digital processing’,Med. Eng. Phys.,16, pp. 35–38
Dunn, A. K., Bolay, H., Moskowitz, M. A., andBoas, D. A. (2001): ‘Dynamic imaging of cerebral blood flow using laser speckle’,J. Cerebr. Blood Flow Metab.,21, pp. 195–201
Englehart, M., andKristensen, J. K. (1983): ‘Evaluation of cutaneous blood flow responses by133Xenon washout and a laser Doppler flowmeter’,J. Invest. Dermatol.,80, pp. 12–15
Ennos, A. E. (1984): ‘Speckle interferometry’ inDainty, J. C. (Ed.): ‘Laser speckle and related phenomena’ (Springer-Verlag, New York)
Essex, T. J. H., andByrne, P. O. (1991): ‘A laser Doppler scanner for imaging blood flow in skin’,J. Biomed. Eng.,14, pp. 189–194
Fercher, A. F., andBriers, J. D. (1981): ‘Flow visualization by means of single-exposure photography’,Opt. Comm.,37, pp. 326–330
Forrester, K., Doschak, M., andBray, R. C. (1997): ‘In-vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: measurement in knee ligaments of adult rabbits’,Med. Biol. Eng. Comput.,35, pp. 581–586
Forrester, K. (2002): ‘Laser imaging of tissue perfusion’. PhD thesis, University of Calgary
Fujii, H., Nohira, K., Yamamoto, Y., Ikawa, H., andOhura, T. (1987): ‘Evaluation of blood flow by laser speckle image sensing’,Appl. Opt.,26, pp. 5321–5325
Fukuoka, S., Hotokebuchi, T., Terada, K., Kobara, N., Fujii, H., Sugioka, Y., andIwamoto, Y. (1999a): ‘Assessment of subchondral blood flow in the rabbit femoral condyle using the laser speckle method’,J. Orth. Res.,17, pp. 368–375
Fukuoka, S., Hotokebuchi, T., Jingushi, S., Fujii, H., Sugioka, Y., andIwamoto, Y. (1999b): ‘Evaluation of blood flow within the subchondral bone of the femoral head: Use of the laser speckle method at surgery for osteonecrosis’,J. Orth. Res.,17, pp. 80–87
Goodman, J. W. (1984): ‘Statistical properties of laser speckle patterns’ inDainty, J. C. (Ed.): ‘Laser speckle and related phenomena’ (Springer-Verlag, New York)
McKechnie, T. S. (1984): ‘Speckle reduction’ inDainty, J. C. (Ed.): ‘Laser speckle and related phenomena’ (Springer-Verlag, New York)
Nilsson, G. E., Tenland, T., andOberg, P. A. (1980): ‘A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy’,IEEE Trans. Biomed. Eng.,27, pp. 597–604
Nilsson, G. E. (1984): ‘Signal processor for laser Doppler flowmeters’,Med. Biol. Eng. Comput.,22, pp. 343–348
Obied, A. N. (1993): ‘In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry’,Med. Biol. Eng. Comput.,31, pp. 43–52
Ruth, B. (1993): ‘Measuring the steady-state value and the dynamics of the skin blood flow using the non-contact laser speckle method’,Med. Eng. Phys.,16, pp. 105–111
Stern, M. D., Lappe, D. L., Bowen, P. D., Chimosky, J. E., Holloway, G. A., Keiser, H. R., andBowman, R. L. (1977): ‘Continuous measurement of tissue blood flow by laser Doppler spectroscopy’,Am. J. Physiol.,232, pp. H441-H448
Wårdell, K., Jakobsson, A., andNilsson, G. E. (1993): ‘Laser Doppler perfusion imaging by dynamic light scattering’,IEEE Trans. Biomed. Eng.,40, pp. 309–316
Watkins, D., andHolloway, G. A. (1978): ‘An instrument to measure cutaneous blood flow using the Doppler shift of laser light’,IEEE Trans. Biomed. Eng.,25, pp. 28–33
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Forrester, K., Stewart, C., Tulip, J. et al. Comparison of laser speckle and laser Doppler perfusion imaging: Measurement in human skin and rabbit articular tissue. Med. Biol. Eng. Comput. 40, 687–697 (2002). https://doi.org/10.1007/BF02345307
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02345307