Skip to main content
Log in

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discretestates machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bergmann, G. (Ed.) (2001): ‘HIP98-Loading of the hip joint’ (Free University, Berlin, 2001)

    Google Scholar 

  • Berry, D. J., Harmsen, W. S., Cabanela, M. E., andMorrey, B. F. (2002): ‘Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components’,J. Bone Joint Surg. Am.,84-A, pp. 171–177

    Google Scholar 

  • Biegler, F. B., Reuben, J. D., Harrigan, T. P., Hou, F. J., andAkin, J. E. (1995): ‘Effect of porous coating and loading conditions on total hip femoral stem stability’,J. Arthroplasty,10, pp. 839–847

    Article  Google Scholar 

  • Bragdon, C. R., Burke, D., Lowenstein, J. D., O_Connor, D. O., Ramamurti, B., Jasty, M., andHarris, W. H. (1996): ‘Differences in stiffness of the interface between a cementless porous implant and cancellous bonein vivo in dogs due to varying amounts of implant motion’,J. Arthroplasty,11, pp. 945–951

    Google Scholar 

  • Chareancholvanich, K., Tanchuling, A., Seki, T., andGustilo, R. B. (1999): ‘Cementless acetabular revision for aseptic failure of cemented hip arthroplasty’,Clin. Orthop. Relat. Res., pp. 140–149

  • Cristofolini, L., Pelgreffi, I., Cappello, A., andToni, A. (2002a): ‘Intraoperative assessment of the primary stability of cementless hip stems’ (European Orthopaedic Research Society, Lausanne, 2002a).

    Google Scholar 

  • Cristofolini, L., Pelgreffi, I., Cappello, A., andToni, A. (2002b): ‘Intra-operative measurament of cementless hip stem torsional stability’. 13th Conf. European Society of Biomechanics, Wroclaw, Poland

  • Dalton, J. E., Cook, S. D., Thomas, K. A., andKay, J. F. (1995): ‘The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants’,J. Bone Joint Surg. [Am.],77, pp. 97–110

    Google Scholar 

  • Delaunay, C. andKapandji, A. I. (2001): ‘Survival analysis of cementless grit-blasted titanium total hip arthroplasties’,J. Bone Joint Surg. Br.,83, pp. 408–413

    Article  Google Scholar 

  • Egan, J. M., andMarsden, D. C. (2001): ‘A spring network model for the analysis of load transfer and tissue reactions in intramedullary fixation’,Clin. Biomech.,16, pp. 71–79

    Article  Google Scholar 

  • Emerson, R. H., Head, W. C., Emerson, C. B., Rosenfeldt, W., andHiggins, L. L. (2002): ‘A comparison of cemented and cementless titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study’,J. Arthroplasty,17, pp. 584–591

    Article  Google Scholar 

  • Engh, C., O’Connor, D., Jasty, M., McGovern, T., Bobyn, J., andHarris, W. (1992): ‘Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses’,Clin. Orthop. Rel. Res., pp. 13–29

  • Fernandes, P. R., Folgado, J., Jacobs, C., andPellegrini, V. (2002): ‘A contact model with ingrowth control for bone remodelling around cementless stems’,J. Biomech.,35, pp. 167–176

    Article  Google Scholar 

  • Gruen, T. A., McNeice, G. M., andAmstutz, H. C. (1979): ‘Modes of failure’ of cemented stem-type femoral components: a radiographic analysis of loosening’,Clin. Orthop. Rel. Res.,141, pp. 17–27

    Google Scholar 

  • Hamlin, B. R., Rowland, C., andMorrey, B. F. (2001): ‘Retention of all-polyethylene acetabular components after femoral revision of a cemented total hip replacement’,J. Bone Joint Surg. Am.,83-A, pp. 1700–1705

    Google Scholar 

  • Hardy, D. C., Frayssinet, P., Guilhem, A., Lafontaine, M. A., andDelince, P. E. (1991): ‘Bonding of hydroxyapatite-coated femoral prostheses. Histopathology of specimens from four cases’,J. Bone Joint Surg. Br.,73, pp. 732–740

    Google Scholar 

  • Healy, W. L. (2002): ‘Hip implant selection for total hip arthroplasty in elderly patients’,Clin. Orthopaed. Rel. Res., pp. 54–64

  • Huo, M. H. (2002): ‘What’s new in hip arthroplasty’,J. Bone Joint Surg. Am. 84-A, pp. 1894–1905

    Google Scholar 

  • IOR (2000): ‘R.I.P.O. Registro dell’Implantologia Protesica Ortopedica. Analisi dell’attività implantologica d’artroprotesi d’anca negli Istituti Ortopedici Rizzoli dal 1990 al 2000’, (Istituti Ortopedici Rizzoli, Bologna, Italia, 2000).

    Google Scholar 

  • Jasty, M., Bragdon, C. R., Zalenski, E., O’Connor, D., Page, A., andHarris, W. H. (1997): ‘Enhanced stability of uncemented canine femoral components by bone ingrowth into the porous coatings’,J. Arthroplasty,12, pp. 106–113

    Article  Google Scholar 

  • Kavanagh, B. F., Dewitz, M. A., Ilstrup, D. M., Stauffer, R. N., andCoventry, M. B. (1989): ‘Charnley total hip arthroplasty with cement. Fifteen-year results’,J. Bone Joint Surg. Am.,71, pp. 1496–1503

    Google Scholar 

  • Khalily, C., andLester, D. K. (2002): ‘Results of a tapered cementless femoral stem implanted in varus’,J. Arthroplasty,17, pp. 463–466

    Google Scholar 

  • Kienapfel, H., Sprey, C., Wilke, A., andGriss, P. (1999): ‘Implant fixation by bone ingrowth’,J. Arthroplasty,14, pp. 355–368

    Article  Google Scholar 

  • Laupacis, A., Bourne, R., Rorabeck, C., Feeny, D., Tugwell, P., andWong, C. (2002): ‘Comparison of total hip arthroplasty performed with and without cement: a randomized trial’,J. Bone Joint Surg. Am.,84-A, pp. 1823–1828

    Google Scholar 

  • Lintner, F., Zweymuller, K., Bohm, G., andBrand, G. (1988): ‘Reactions of surrounding tissue to the cementless hip implant Ti-6A1-4V after an implantation period of several years. Autopsy studies in three cases’,Arch. Orthop. Trauma Surg.,107, pp. 357–363

    Article  Google Scholar 

  • Lintner, F., Zweymuller, K., andBrand, G. (1986): ‘Tissue reactions to titanium endoprostheses. Autopsy studies in four cases’,J. Arthroplasty,1, pp. 183–195

    Google Scholar 

  • Manley, P. A., Vanderby, R., Kohles, S., Markel, M. D., andHeiner, J. P. (1995): ‘Alterations in femoral strain, micromotion, cortical geometry, cortical porosity, and bony ingrowth in uncemented collared and collarless prostheses in the dog’,J. Arthroplasty,10, pp. 63–73

    Article  Google Scholar 

  • Manley, M. T., Capello, W. N., D’Antonio, J. A., Edidin, A. A., andGeesink, R. G. (1998): ‘Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years’,J. Bone Joint Surg. Am.,80, pp. 1175–1185

    Google Scholar 

  • McCarthy, C. K., Steinberg, G. G., Agren, M., Leahey, D., Wyman, E., andBaran, D. T. (1991): ‘Quantifying bone loss from the proximal femur after total hip arthroplasty’,J. Bone Joint Surg. Br.,73, pp. 774–778

    Google Scholar 

  • Monti, L., Cristofolini, L., Toni, A., andCeroni, R. G. (2001): ‘In vitro testing of the primary stability of the VerSys enhanced taper stem: a comparative study in intact and intraoperatively cracked femora’,Proc. Inst. Mech. Eng. H, J. Eng. Med.,215, pp. 75–83

    Google Scholar 

  • Niinimaki, T., Junila, J., andJalovaara, P. (2001): ‘A proximal fixed anatomic femoral stem reduces stress shielding’,Int. Orthop.,25, pp. 85–88

    Google Scholar 

  • Pancanti, A., Bernakiewicz, M., andViceconti, M. (2003): ‘Inter-subject variability affects the primary stability of cementless stems more than the type of motor task’,J. Biomech.,36, pp. 777–785

    Article  Google Scholar 

  • Pilliar, R., Lee, J., andManiatopoulos, C. (1986): ‘Observations on the effect of movement on bone ingrowth into porous-surfaced implants’,Clin. Orthop. Rel. Res., pp. 108–113

  • Pritchett, J. W. (1995): ‘Femoral bone loss following hip replacement. A comparative study’,Clin. Ortho. Rel. Res., pp. 156–161

  • Rorabeck, C. H., Bourne, R. B., Mulliken, B. D., Nayak, N., Laupacis, A., Tugwell, P., andPeeney, D. (1996): ‘The Nicolas Andry award: comparative results of cemented and cementless total hip arthroplasty’,Clin. Orthop. Rel. Res., pp. 330–344

  • Sadegh, A. M., Luo, G. M., andCowin, S. C. (1993): ‘Bone ingrowth: an application of the boundary element method to bone remodeling at the implant interface’,J. Biomech.,26, pp. 167–182

    Article  Google Scholar 

  • Sanchez-Sotelo, J., Berry, D. J., andHarmsen, S. (2002): ‘Long-term results of use of a collared matte-finished femoral component fixed with second-generation cementing techniques. A fifteen-year-median follow-up study’,J. Bone Joint Surg. Am.,84-A, pp. 1636–1641

    Google Scholar 

  • Skripitz, R., andAspenberg, P. (1998): ‘Tensile bond between bone and titanium: a reappraisal of osseointegration’,Acta Orthop. Scand.,69, pp. 315–319

    Google Scholar 

  • Smith, S. E., Garvin, K. L., Jardon, O. M., andKaplan, P. A. (1991): ‘Uncemented total hip arthroplasty. Prospective analysis of the tri-lock femoral component’,Clin. Orthop. Rel. Res., pp. 43–50

  • Soballe, K., Hansen, E. S., Brockstedt-Rasmussen, H., Pedersen, C. M., andBunger, C. (1990): ‘Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit’,Acta Orthopaed. Scand.,61, pp. 299–306

    Google Scholar 

  • Soballe, K., Gotfredsen, K., Brockstedt-Rasmussen, H., Nielsen, P. T., andRechnagel, K. (1991): ‘Histologic analysis of a retrieved hydroxyapatite-coated femoral prosthesis’,Clin. Orthop. Rel. Res., pp. 255–258

  • Soballe, K., Brockstedt-Rasmussen, H., Hansen, E. S., andBunger, C. (1992a): ‘Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs’,Acta Orthopaed. Scand.,63, pp. 128–140

    Google Scholar 

  • Soballe, K., Hansen, E. S., Rasmussen, H., Jorgensen, P. H., andBunger, C. (1992): ‘Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions’,J. Orthopaed. Res.,10, pp. 285–299

    Google Scholar 

  • Soballe, K., Hansen, E. S., Brockstedt-Rasmussen, H., andBunger, C. (1993): ‘Hydroxyapatite coating converts fibrous tissue to bone around loaded implants’,J. Bone Joint Surg.,75, pp. 270–278

    Google Scholar 

  • Spears, I. R., Pfleiderer, M., Schneider, E., Hille, E., Bergmann, G., andMorlock, M. M. (2000): ‘Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth’,J. Biomech.,33, pp. 1471–1477

    Article  Google Scholar 

  • Toni, A., Paderni, S., Sudanese, S., Sudanese, A., Guerra, E., Traina, F., Giardina, F., Antonietti, B., Giunti, A. (2001): ‘Anatomic cementless total hip arthroplasty with ceramic bearings and modular necks: 3 to 5 years follow up’,Hip Int.,1, pp. 1–17

    Google Scholar 

  • Tonino, A. J., Therin, M., andDoyle, C. (1999): ‘Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem’,J. Bone Joint Surg. Br.,81, pp. 148–154

    Article  Google Scholar 

  • Viceconti, M., Muccini, R., Bernakiewicz, M., Baleani, M., andCristofolini, L. (2000): ‘Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration’,J. Biomech.,33, pp. 1611–1618

    Article  Google Scholar 

  • Viceconti, M., Monti, L., Muccini, R., Bernakiewicz, M., andToni, A. (2001): ‘Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems’,Clin. Biomech.,16, pp. 765–775

    Article  Google Scholar 

  • Vresilovic, E. J., Hozack, W. J. andRothman, R. H. (1994): ‘Radiographic assessment of cementless femoral components. Correlation with intraoperative mechanical stability’,J. Arthroplasty,9, pp. 137–141

    Article  Google Scholar 

  • Weber, D., Schaper, L. A., Pomeroy, D. L., Badenhausen, W. E., Curry, J. I., Smith, M. W., andSuthers, K. E. (2000): ‘Cementless hemispheric acetabular component in total hip replacement’,Int. Orthop.,24, pp. 130–133

    Google Scholar 

  • Weinans, H., Huiskes, R., andGrootenboer, H. J. (1990): ‘Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses’,J. Biomech.,23, pp. 991–1000

    Article  Google Scholar 

  • Widmer, K. H., Zurfluh, B., andMorscher, E. W. (2002): ‘Load transfer and fixation mode of press-fit acetabular sockets’,J. Arthroplasty,17, pp. 926–935

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Viceconti.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Viceconti, M., Pancanti, A., Dotti, M. et al. Effect of the initial implant fitting on the predicted secondary stability of a cementless stem. Med. Biol. Eng. Comput. 42, 222–229 (2004). https://doi.org/10.1007/BF02344635

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02344635

Keywords

Navigation