The effect of a sprinkler on the stability of a smoke layer beneath a ceiling

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

A study has been made of the effect of sprinkler sprays on hot buoyant smoke layers with particular reference to covered shopping malls.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

A :

Cross-sectional area of drop, m2

B :

Buoyancy force, N

C D :

Drag coefficient, dimensionless

C d :

Discharge coefficient, dimensionless

D :

Drag force, N

d :

Drop diameter, m

h :

Depth of hot layer, m

k :

Drag constant of proportionality, kg m−1

\(\dot M\) :

Mass flow rate of water, kg s−1

m :

Mass of drop, kg

p :

Pressure, N m−2

T :

Absolute temperature, ° K

v :

Velocity of drop, m s−1

μ :

Absolute coefficient of viscosity, Ns m−2

ρ :

Density, kg m−3

ϑ :

Temperature difference, ° C

a :

Referring to air

c :

Referring to the condition when drag and buoyancy forces are equal

o :

Referring to ambient datum conditions

to :

Referring to water

References

  1. Hinkley, P. L., “A Preliminary Note on the Movement of Smoke in an Enclosed Shopping Mall,” Fire Research Station, Fire Research Note 806, Borehamwood, 1970.

  2. Hinkley, P. L., “Some Notes on the Control of Smoke in Enclosed Shopping Centres,” Fire Research Station, Fire Research Note 875, Borehamwood, 1971.

  3. Heselden, A. J. M., “Fire Problems of Pedestrian Precincts. Part 1. The Smoke Production of Various Materials,” Fire Research Station, Fire Research Note 856, Borehamwood, 1971.

  4. Heselden, A. J. M., Wraight, H. G. H., and Watts, P. R. H., “Fire Problems in Pedestrian Precincts. Part 2. Large Scale Experiments With a Shaft Vent,” Fire Research Station, Fire Research Note 954, Borehamwood, 1972.

  5. D'Auria, C., “Protection Against Fire in Garages,” Anticendio e Protezione Civile, Vol. 9 (1973), pp. 640–642.

    Google Scholar 

  6. Operation School Burning, Los Angeles Fire Department, National Fire Protection Association, Boston, Vol. 1 (1959), Vol. 2 (1961).

  7. Massey, B. S.,Mechanics of Fluids, Van Nostrand, New York (1968).

    Google Scholar 

  8. Morgan, H. P. and Bullen, M. L., “The Extraction of Smoke by a Ducted Water Spray,” Fire Research Station, Fire Research Note 1010, Borehamwood, 1974.

  9. Yao, C. and Kalelkar, A. S., “Effect of Drop Size on Sprinkler Performance,”Fire Technology, Vol. 6, No. 4 (1970), pp. 254–68.

    Google Scholar 

  10. Rules for Automatic Sprinkler Installations, 29th Edition. Fire Offices' Committee, London, 1968.

  11. O'Dogherty, M. J., Nash, P. and Young, R. A., “A Study of the Performance of Automatic Sprinkler Systems.” Fire Research Station, Fire Research Technical Paper No. 17. H. M. Stationery Office, 1966.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bullen, M.L. The effect of a sprinkler on the stability of a smoke layer beneath a ceiling. Fire Technol 13, 21–34 (1977). https://doi.org/10.1007/BF02338883

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02338883

Keywords

Navigation