Summary
First trimester amniotic fluid is an ultrafiltrate of maternal plasma and constitutes the major component of gestational sac volume (GSV). We hypothesized that GSV, assessed by 3-dimensional (3-D) ultrasound volumetry, would reflect function of the early uteroplacental unit and therefore provide a basis for predicting pregnancy outcome. We tested this hypothesis in 38 pregnancies which had first trimester GSV measurements by two investigators thus allowing determination of interobserver variation. Gestational age (GA) was based on a careful history and conventional 2-dimensional ultrasound measurements. Serum forβ-hCG, estradiol (E2) and progesterone (P) was obtained at the time of ultrasound examinations. “Normal” outcome was defined as confirmation of a viable fetus. “Abnormal outcome” was defined as either a “blighted ovum” or embryonic demise. Statistical analysis was performed by Independent t-test and regression analysis. There were 31 “normal” and 7 “abnormal” pregnancies studied between 5 and 11 weeks gestation (mean±SD 8.3±1.3 weeks). GSV was significantly correlated to GA (r=0.74,P<0.001), higher than toβ-bCG (r=0.40,P=0.034), E2 (r=0.70,P< 0.001) and P (r=0.21,P=0.334), respectively. In the abnormal group 2/2 pregnancies with a twin sac had a GSV within 1 SD of the mean. 3/5 cases of missed abortions or blighted ovum had a GSV < 2 SD of the mean. The interobserver correlation was high (r=0.99,P<0.001). This is the first clinical study investigating the diagnostic use of 3-D ultrasound volumetry in first trimester pregnancy. Our results suggest that GSV volumetry has the potential to predict pregnancy survival into the mid to late trimester.
Similar content being viewed by others
References
Edmonds DK, Lindsay KS, Millier JF, Williamson MB and Wood PJ (1982) Early embryonic mortality in women. Fertil Steril 38:447–453
Gregg AR, Steiner H, Staudach A, Weiner CP (1993) Accuracy of 3D sonographic volume measurements. Am J Obstet Gynecol 168:348
Kuo HC, Chang FM, Wu CH, Yao BL, Liu CH (1992) The primary application of three-dimensional ultrasonography in obstetrics. Am J Obstet Gynecol 166:880–886
Nelson TR, Pretorius DH (1992) Three-dimensional ultrasound of fetal surface features. Ultrasound Obstet Gynecol 2:166–174
Pretorius DH, Nelson TR (1991) Three-dimensional ultrasound imaging in patient diagnosis and management: the future. Ultrasound Obstet Gynecol 1:381–382
Rosen GF, Silva PD, Patrizio P, Asch RH, Yee B (1990) Predicting pregnancy outcome by the observation of a gestational sac or of early fetal cardiac motion with transvaginal ultrasonography. Fertil Steril 54:260–264
Sohn Ch, Stolz W, Nuber B, Hesse A, Hornung B (1991) Die dreidimensionale Ultraschall-diagnostik in Gynäkologie und Geburtshilfe. Geburtshilfe Frauenheilkd 51:335–340
Steiner H, Staudach A, Spitzer D, Graf AH, Wienerroither H (1993) 3D-sonography provides new aspects in obstetrical and gynecological ultrasound. Geburtshilfe Frauenheilkd 53:779–782
Wilcox AJ, Weinberg CR, O'Connor JF, Baird DD, Schlatterer JP, Canfield RE, Armstrong EG, Nisula BC (1988) Risk of spontaneous abortion in ultrasonically normal pregnancies. N Engl J Med 319:189–194
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Steinen, H., Gregg, A.R., Bogner, G. et al. First trimester three-dimensional ultrasound volumetry of the gestational sac. Arch Gynecol Obstet 255, 165–170 (1994). https://doi.org/10.1007/BF02335080
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02335080