Abstract
In order to calculate coincidence correction factors when measuring with a low-energy photon detector (LEPD), algorithms were developed for the description of the summing-out probabilities taking into account γ-LX in addition to γ-γ and γ-KX true-coincidences, where KX and LX can originate from internal conversion and electron capture. The accuracy of the calculation procedure is experimentally checked. The work presented here is part of an extension of the NAA k0-standardization to counting in a LEPD.
Similar content being viewed by others
References
F. DE CORTE, A. SIMONITS, A. DE WISPELAERE, J. HOSTE, J. Radioanal. Nucl. Chem., 113 (1987) 145.
K. DEBERTIN, R. G. HELMER, Gamma- and X-ray spectrometry with semiconductor detectors, North Holland, Amsterdam, 1988.
D. S. AANDREEV, K. I. EROKHINA, V. S. ZVONOV, I. K. LEMBERG, Instrum. Exp. Tech., 25 (1972) 1358.
D. S. AANDREEV, K. I. EROKHINA, V. S. ZVONOV, I. K. LEMBERG, Izv. Akad. Nauk SSR Ser. Fiz., 37 (1973) 1609.
G. J. McCALLUM, G. E. COOTE, Nucl. Instr. Methods, 130 (1975) 189.
K. DEBERTIN, U. SCHÖTZIG, Nucl. Instr. Methods, 158 (1979) 471.
L. MOENS, De k0-comparatormethode als nieuwe standaardisatietechniek in reactorneutronenactiveringsanalyse, Ph. D. Thesis, University of Gent, 1981.
L. MOENS, F. DE CORTE, A. SIMONITS, LIN XILEI, A. DE WISPELAERE, J. DE DONDER, J. HOSTE, J. Radioanal. Chem., 70 (1982) 539.
J. MOREL, B. CHAUVENAT, A. KADACHI, Int. J. Appl. Radiat. Isot., 34 (1983) 1115.
K. SINKHO, H. AALTONEN, Report STUK-B-VALO 40, Helsinki, Finland, 1985.
M. C. LEPY, J. MOREL, B. CHAUVENET, Correction des pertes de comptage dues aux coincidences gamma-gamma, gamma-X et X-X dans un spectre de photons, Rapport CEA-R-5356, CEN Saclay, 1986.
F. DE CORTE, The k0-standardization method: a move to the optimization of neutron activation analysis, Habilitation Thesis, University of Gent, 1987.
F. DE CORTE, M. C. FREITAS, A. DE WISPELAERE, Nucl. Instr. Methods, A299 (1990) 335.
L. MOENS, J. DE DONDER, LIN XILEI, F. DE CORTE, A. DE WISPELAERE, A. SIMONITS, J. HOSTE, Nucl. Instr. Methods, 187 (1981) 451.
L. MONES, J. HOSTE, Int. J. Appl. Radiat. Isot., 34 (1983) 1085.
E. BROWNE, R. B. FIRESTONE, Table of radioactive isotopes, V. S. SHIRLEY (Ed.), Wiley, N. Y., 1986.
F. RÖSEL, H. M. FRIES, K. AALDER, H. C. PAULI, Atomic Data and Nuclear Data Tables, 21 (2, 3) (1978) 92; 21 (4, 5) (1978) 292.
Table de Radionucléides, Report CEA/BNM/LMRI, 1978; 1980; 1985.
W. BAMBYNEK, H. BEHRENS, M. H. CHEN, B. CRASEMANN, M. L. FITZPATRICK, K. W. D. LEDINGHAM, H. GENZ, M. MUTTERER, R. L. INTEMAN, Revs. Mod. Phys., 49 (1977) 77.
C. M. LEDERER, V. S. SHIRLEY (Eds), Table of Isotopes, 7th ed., J. Wiley and Sons, N. Y., 1978.
W. BAMBYNEK, Production of inner-shell vacancies by orbital electron capture of the nucleus and by internal conversion of gamma-rays, Proc. 2nd Intern. Summer School on Low-Level Measurements of Man-Made Radionuclides in the Environment, La Rábida, Huelva, Spain, 24 June–6 July, 1990 (in press).
J. HERTOGEN, R. GIJBELS, Anal. Chim. Accta, 56 (1971) 61.
M. C. FREITAS, F. DE CORTE, to be presented at the 8th MTAA Conference, Vienna, 1991.
F. BELLEMANS, private communication, 1991.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
De Corte, F., Freitas, M.C. The correction for γ-γ, γ-KX and γ-LX true-coincidences in k0-standardized NAA with counting in a LEPD. Journal of Radioanalytical and Nuclear Chemistry, Articles 160, 253–267 (1992). https://doi.org/10.1007/BF02041675
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02041675