Abstract
An XRF-method for the determination of Sm, Gd, Dy, Er and Eu in uranium solution by use of simple polyethylene bottles has been established. Spectral interferences and matrix effects like absorption enhancement have been rectified using standards of similar composition in the absence of internal standard. Analytical application of the method used has been established on the basis of statistical evaluation.
Similar content being viewed by others
References
J. D. WEINFORDNER, Trace Analysis Spectroscopic Methods for Elements, John Wiley and Sons, 1970.
V. B. RYABININ, I. L. AGAFONOV, N. V. LARIN, Poluch. Anal. Chist.-Veschestv., 1 (1976) 51.
R. A. FASSEL, Anal. Chem., 32 (1960) 19A.
R. M. DIXIT, Bull. Mater. Sci., 3 (1981) 371.
L. V. AGAPOVA, A. V. ANTONOV, N. V. TRONEV, N. V. BAGAEV, Zavod. Lab., 47 (1981) 45.
V. A. POBEDONOSTSEV, L. A. RADKEVICH, T. E. SHCHUR, Tekhnal. i. Izuch. Soedin. Redkevich, Elementov. Apatity. (1983) 49.
D. CHOPRA, H. NARAGHI, J. Less-Common Met., 93 (1983) 203.
LU SHAOLON, XU PEIZHEN, LI JIANHUA, Zhongguo Xitu Xuebao., 2 (1984) 88.
LU SHAOLON, XU PEIZHEN, LI JIANHUA, LI MINGJIE, New Front. Rare Earch Sci. Appl., Proc. Int. Conf. Rare Earth Appl., 1 (1985) 553.
L. C. CHANDOLA, P. P. KHANNAS; Report BARC-1246, 1986.
R. M. DIXIT, S. S. DESHPANDE, Report BARC-1275, 1985.
L. C. CHANDOLA, P. P. KHANNA, J. Radioanal. Nucl. Chem., 121 (1988) 53.
E. L. CHUPP, J. W. M. DU MOND, F. J. GORDON, R. C. JOPSON, HANS MARK, Physical Review, 112 (1958) 1183.
T. HUGHES, C. MCKENZIE, J. WASCHL, Proc. 2nd Aust. Conf. Nucl. Anal., 1978, p. 30.
C. S. SASTRI, P. MOELLER, Radiochem. Radioanal. Letters, 40 (1979) 103.
R. P. H. GARTEN, K. O. GROENVELD, K. H. KOENING, Fresen. Z. Anal. Chem., 307 (1981) 97.
A. V. GUREVICH, Z. V. VIKHROVA, V. Ya. VYROPAYEV, V. I. DRYNKIN, D. I. LEIPUN-SKAYA, I. Ya. SHIROKOVA, J. Radioanal. Chem., 57 (1980) 417.
J. J. LABRECQUE, Anal. Chim. Acta, 188 (1986) 9.
G. LAGARDE, J. LARCHER, J. Radioanal. Nucl. Chem., 105 (1986) 341.
MANDAN LAL, R. K. CHOUDHURY, R. M. AGRAWAL, X-Ray Spectrom., 16 (1987) 23.
T. A. KUADA, de raios-X, 1984.
WANG ZIYAO, LIN JINGWIANG, HE CHUNFU, LI YING, Fenxi Huaxue, 12 (1984) 749.
WANG ZIYAO, HE CHUNFU, LIN PEIXIN, Fenxi Huaxue, 13 (1985) 105.
I. M. CITRON, Report ANL-81-85-Pt, 1982.
R. M. AGRAWAL, S. K. KAPOOR, X-Ray Spectrom., 16 (1987) 81.
A. B. BLANK, L. E. BELENKO, N. I. SHEVTSOV, Zh. Analit. Khim., 41 (1986) 286.
M. K. KEYA, D. A. SERRA, Cicnc. Cult. Sulp., 31 (1979) 334.
V. A. RYABUKHIN, N. G. GATIONSKAYA, A. N. ERMAKOV, S. D. SHEVALEEVSKII, Zh. Analit. Khim., 38 (1983) 1626.
R. PLESCH, B. THIEL, Siemens. Anal. Appl. Note 196.
X-Ray Wavelength and 2ϑ-Table, N. V. Philips Gloeilampenfabrieken Holland, X-Ray Application Laboratories.
R. JENKINS, J. L. DEVRIES, Worked Example in X-Ray Anal. Philips Technical Library, Mac-Millan Press Ltd., 2nd ed., 1978.
V. MACHACEK, D. WEISS, X-Ray Spectrom., 15 (1985) 53.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Saleem, M., Afzal, M., Hanif, J. et al. Determination of lanthanides in uranium solutions by X-ray fluorescence spectrometry. Journal of Radioanalytical and Nuclear Chemistry, Articles 142, 393–402 (1990). https://doi.org/10.1007/BF02040309
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02040309