Based on the phase difference method as described by Nayler et al. we developed a gradient-echo sequence, which refocuses flow related phase shifts even for infants with their higher peak velocity, higher acceleration and faster heart rates. A repetition time (TR) of 15 ms provides a high temporal resolution for dynamic studies. Modification of the flow-rephasing gradient-echo sequence in slice select direction leads to a defined phase shift and the resultant phase difference images allow blood flow measurements in the great arteries and the calculation of blood volume per heart cycle (flow volume) to assess left and right ventricular stroke volume. This can also be achieved by calculation of the ventricular volume from contiguous slices of the whole heart, but, this in excessive measuring times. Both methods were applied in 6 examinations of children with congenital heart diseases (1 pulmonary sling, 1 coarctation of the aorta, 1 ventricular septal defect, 3 atrial septal defects). The age of the patients ranged from 3 months to 13.4 years (mean age 4.9 years). The regression analyses of both methods show a high correlation for systemic flow (y=-0.98+1.08 x r=0.99, SEE=2.59 ml) and for pulmonary flow (y=−1.40+0.96 x, r=0.99, SEE=4.70 ml). The comparison of flow calculated Qp:Qs ratio and chamber size calculated Qp:Qs ratio with data obtained by heart catheterization show also a regression line close to the line of identity (y=−0.01+1.04 x, r=0.98, SEE=0.15 and y=0.28+0.96 x, r=0.81, SEE=0.47, respectively).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Didier D, Higgins CB, Fisher MR, Osaki L, Silverman NH, Cheitlin MD (1986) Congenital heart disease: gated MR imaging in 72 patients. Radiology 158:227–235

    PubMed  Google Scholar 

  2. Higgins CB (1986) Overview of MR of the heart-1986. AJR 146:907–918

    PubMed  Google Scholar 

  3. Sieverding L, Klose U, Apitz J (1990) Morphological diagnosis of congenital and acquired heart disease by magnetic resonance imaging. Pediatr Radiol 20:311–319

    PubMed  Google Scholar 

  4. Rees S, Firmin D, Mohiaddin R, Underwood R, Longmore D (1989) Application of flow measurements by magnetic resonance velocity mapping to congential heart disease. Am J Cardiol 64:953–956

    PubMed  Google Scholar 

  5. Nayler GL, Firmin DN, Longmore DB (1986) Blood flow imaging by cine magnetic resonance. J Comput Assist Tomogr 10:715–722

    PubMed  Google Scholar 

  6. Sieverding L, Klose U, Apitz J (1989) Blood flow measurements in the great arteries and its limitation in infancy and babyhood. SMRM, 8th Annual Meeting and Exhibition 12–18. August Amsterdam. Book of Abstracts 1:316

    Google Scholar 

  7. Sieverding L, Jung W-I, Klose U, Apitz J (1990) Refocusing gradient echo sequence: blood flow measurement and other applications in pediatric cardiology. ESMRMB, 7th Annual Congress 2.–5. Mai Straßburg. Book of Abstracts 1:44

    Google Scholar 

  8. Firmin DN, Nayler GL, Klipstein RH, Underwood SR, Rees RS, Longmore DB (1987) In vivo validation of MR velocity imaging. J Comput Assist Tomogr 11:751–756

    PubMed  Google Scholar 

  9. Loeber CP, Goldberg SJ, Marx GR, Carrier M, Emery RW (1987) How much does aortic and pulmonary artery area vary during the cardiac cycle? Am Heart J 113:95–100

    PubMed  Google Scholar 

  10. Jenni R, Ritter M, Vieli A, Hirzel HO, Schmid ER, Grimm J, Turina M (1989) Determination of the ratio of pulmonary blood flow to systemic blood flow by derivation of amplitude weighted mean velocity from continuous wave Doppler spectra. Br Heart J 61:67–71

    Google Scholar 

  11. Bogren HG, Klipstein RH, Firmin DN, Mohiaddin RH, Underwood SR, Rees RS, Longmore DB (1989) Quantitation of antegrade and retrograde blood flow in the human aorta by magnetic resonance velocity mapping. Am Heart J 117:1214–1222

    PubMed  Google Scholar 

  12. Bogren HG, Klipstein RH, Mohiaddin RH, Firmin DN, Underwood SR, Rees RS, Longmore DB (1989) Pulmonary artery distensibility and blood flow patterns: a magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertension. Am Heart J 118:990–999

    PubMed  Google Scholar 

  13. Sechtem U, Pflugfelder PW, Gould RG, Cassidy MM, Higgins CB (1987) Measurements of right and left ventricular volumes in healthy individuals with cine MR imaging. Radiology 163:697–702

    PubMed  Google Scholar 

  14. Underwood SR, Gill CR, Firmin DN, Klipstein RH, Mohiaddin RH, Rees RS, Longmore DB (1988) Left ventricular volume measured rapidly by oblique magnetic resonance imaging. Br Heart J 60:188–195

    PubMed  Google Scholar 

  15. Pflugfelder PW, Sechtem U, White RD, Higgins CB (1988) Quantification of regional myocardial function by rapid cine MR imaging. AJR 150:523–529

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Financial support by the Bundesministerium für Forschung und Technologie (BMFT) of the Federal Republic of Germany (Grant 01VF8519/7) and the Kuhnstiftung is gratefully acknowledged.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sieverding, L., Jung, W.I., Klose, U. et al. Noninvasive blood flow measurement and quantification of shunt volume by cine magnetic resonance in congenital heart disease. Pediatr Radiol 22, 48–54 (1992). https://doi.org/10.1007/BF02011608

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02011608

Keywords

Navigation