Abstract
The optimal technique for diagnosing nosocomial bacterial pneumonia in critically ill patients cared for in the intensive care unit remains unclear, especially in the subgroup of patients requiring mechanical ventilation. An important advance has been the development of the protected specimen brush technique. We and others have demonstrated that secretions obtained using this technique and evaluated by quantitative cultures are useful in distinguishing patients with and without pneumonia. However, this procedure has important limitations in that results are not available immediately and in that a few false negative or false positive results may be observed. Recently, the use of bronchoalveolar lavage has been suggested to be of value in establishing the diagnosis of pneumonia, since the cells and liquid recovered can be examined microscopically immediately after the procedure and are also suitable for quantitative culture. We believe that microscopic identification of bacteria within cells recovered by lavage may provide a sensitive and specific means for early and rapid diagnosis of pneumonia in this setting and that the lavage technique can be conveniently incorporated into a protocol along with the quantitative culture of samples obtained using the protected specimen brush. This combination will probably improve the overall accuracy of diagnosis while allowing the administration of prompt empiric antimicrobial therapy in the majority of patients with pneumonia.
Similar content being viewed by others
References
Craven, D. E., Driks, M. R. Nosocomial pneumonia in the intubated patient. Seminars in Respiratory Infections 1987, 2: 20–33.
Johanson, W. G., Pierce, A. K., Sanford, J. P., Thomas, G. D. Nosocomial respiratory infections with gram-negative bacilli. The significance of colonization of the respiratory tract. Annals of Internal Medicine 1972, 77: 701–706.
Andrews, C. P., Coalson, J. J., Smith, J. D., Johanson, W. G. Jr. Diagnosis of nosocomial bacterial pneumonia in acute, diffuse lung injury. Chest 1981, 80: 254–258.
Bell, R. C., Coalson, J. J., Smith, J. D., Johanson, W. G. Jr. Multiple organ system failure and infection in adult respiratory distress syndrome. Annals of Internal Medicine 1983, 99: 293–298.
Bartlett, J. G., Alexander, J., Mayhew, J., Sullivan-Sigler, N., Gorbach, S. L. Should fiberoptic bronchoscopy aspirates be cultured? American Review of Respiratory Disease 1976, 114: 73–78.
Matthew, E. B., Holstrom, F. M. G., Kasper, R. L.: A simple method for diagnosing pneumonia in intubated or tracheostomized patients. Critical Care Medicine 1977, 76–81.
Davidson, M., Tempest, B., Palmer, D. L. Bacteriologic diagnosis of acute pneumonia. Comparison of sputum, transtracheal aspirates and lung aspirates. Journal of the American Medical Association 1976, 235: 158–163.
Gherman, C. R., Simon, H. R. Pneumonia complicating severe underlying disease: a current appraisal of transthoracic lung puncture. Disease of the Chest 1965, 48: 297–304.
Wimberley, N., Faling, L. J., Bartlett, J. G. A fiberoptic bronchoscopy technique to obtain uncontaminated lower airway secretions for bacterial culture. American Review of Respiratory Disease 1979, 119: 337–343.
Higuchi, J. H., Coalson, J. J., Johanson, W. G. Jr. Bacteriologic diagnosis of nosocomial pneumonia in primates. Usefulness of the protected specimen brush. American Review of Respiratory Disease 1982, 125: 53–57.
Moser, K. M., Maurer, J., Jassy, L., Kremsdorf, R., Konopka, R., Shure, D., Harrel, J. H. Sensitivity, specificity and risk of diagnostic procedures in a canine model ofStreptococcus pneumoniae pneumonia. American Review of Respiratory Disease 1982, 125: 436–442.
Chastre, J., Viau, F., Brun, P., Pierre, J., Dauge, M. C., Bouchama, A., Akesbi, A., Gibert, C. Prospective evaluation of the protected specimen brush for the diagnosis of pulmonary infections in ventilated patients. American Review of Respiratory Disease 1984, 130: 924–929.
Villers, D., Deriennic, M., Raffi, F., Germaud, P., Baron, D., Nicolas, F., Courtieu, A. L. Reliability of the bronchoscopic protected catheter brush in intubated and ventilated patients. Chest 1985, 88: 527–530.
Baughman, R. P., Thorpe, J. E., Staneck, J., Rashkin, M., Frame, P. T. Use of the protected specimen brush in patients with endotracheal or tracheostomy tubes. Chest 1987, 91: 233–236.
Fagon, J. Y., Chastre, J., Hance, A., Guiguet, M., Trouillet, J. L., Domart, Y., Pierre, J., Gibert, C. Detection of nosocomial lung infection in ventilated patients. Use of a protected specimen brush and quantitative culture techniques in 147 patients. American Review of Respiratory Disease 1988, 138: 110–116.
Torzillo, P. J., McWilliam, D. B., Young, I. H., Woog, R. H., Benn, R. Use of protected telescoping brush system in the management of bacterial pulmonary infection in intubated patients. British Journal of Diseases of the Chest 1985, 79: 125–131.
Marquette, C. H., Ramon, P., Courcol, R., Wallaert, B., Tonnel, A. B., Voisin, C. Bronchoscopic protected catheter biopsy for the diagnosis of pulmonary infections. Chest 1988, 93: 746–750.
Torres, A., Puig de la Bellacasa, J., Rodriguez-Roisin, R., Jimenez de Anta, M. T., Agustin-Vidal, A. Diagnostic value of telescoping plugged catheters in mechanically ventilated patients with bacterial pneumonia using the Metras catheter. American Review of Respiratory Disease 1988, 138: 117–120.
Johanson, W. G. Jr., Seidenfeld, J. J., Gomez, P., De Los Santos, R., Coalson, J. J. Bacteriologic diagnosis of nosocomial pneumonia following prolonged mechanical ventilation. American Review of Respiratory Disease 1988, 137: 259–264.
Thorpe, J. E., Baughman, R. P., Frame, P. T., Wesseler, T. A., Staneck, J. L. Bronchoalveolar lavage for diagnosing acute bacterial pneumonia. Journal of Infectious Diseases 1987, 155; 855–861.
Kahn, F. W., Jones, J. M. Diagnosing bacterial respiratory infection by bronchoalveolar lavage. Journal of Infectious Diseases 1987, 155: 862–869.
Chastre, J., Fagon, J. Y., Sder, P., Bornet, M., Domart, Y., Trouillet, J. L., Gibert, C., Hance, A. J. Diagnosis of nosocomial pneumonia in intubated patients undergoing ventilation: comparison of the usefulness of bronchoalveolar lavage and the protected specimen brush. American Journal of Medicine 1988, 85: 499–506.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Chastre, J., Fagon, J.Y., Domart, Y. et al. Diagnosis of nosocomial pneumonia in intensive care unit patients. Eur. J. Clin. Microbiol. Infect. Dis. 8, 35–39 (1989). https://doi.org/10.1007/BF01964118
Issue Date: