Abstract
Aim of the study was to assess the relative usefulness of transesophageal echocardiography (TEE) and X-ray computed tomography (CT) in the follow-up of patients who survived an aortic dissection.
Materials and Methods. We evaluated 44 patients (age = 57±12 years) with treated aortic dissection: 14 had a De Bakey type I, 20 a type II and 1 patient a type III dissection treated surgically; 1 patient had a type I, 1 a type II and 7 a type III dissection treated medically. All entered an outpatient follow-up program with serial evaluations at 1, 6 and 12 months after initial diagnosis by dual noninvasive imaging protocol. A contrast-enhanced CT scan and a TEE with biplane probe were performed on the same day and in random order.
Results. A total of 252 evaluations with both CT and TEE were considered. A completely normal study was found in 45 TEE and 48 CT evaluations. The following abnormal findings could be documented by one or both techniques: thrombus in the false lumen (TEE: n=48; CT: n=45 evaluations); intimal flap (TEE and CT: n=68); aortic dilatation (TEE and CT: n=15); pericardial effusion (TEE and CT: n=3); aortic pseudoaneurysm (TEE: n=2; CT: n=3); isthmic coarctation (TEE and CT: n=1). Regarding the presence or absence of these abnormalities, which are within the diagnostic domain of both imaging techniques, the results were fully concordant in 245 studies, and discordant in 7, with an overall agreement of 97%. In addition, some abnormal findings could be detected by TEE only: aortic insufficiency (n=36); intimal tear (n=25); spontaneous echocontrast effect in the false lumen (n=39 evaluations). Other abnormal findings could be detected by CT only: a pleural effusion in 4, a truncus anonymous dissection in 1, a pseudoaneurysm due to suture dehiscence of the distal anastomosis of the ascending aorta in 1 evaluation (which yielded ambiguous results by TEE, with turbulent flow departing from the graft).
Conclusion. Both CT and TEE are atraumatic, safe and accurate techniques for serial follow-up imaging of patients treated for aortic dissection. Information provided by CT is largely redundant, rather than additive, to that provided by TEE. The latter should be probably preferred for shorter imaging time, accuracy and convenience, although CT might still play a role in selected cases of ambiguous TEE results.
Similar content being viewed by others
References
Doroghazi RM, Slater EE, De Sanctis RW, Buckley MJ, Austen WG, Rosenthal S. Long-term survival of patients with treated aortic dissection. J Am Coll Cardiol 1984; 3: 1026–1034
Guthaner DF, Miller DC. Digital subtraction angiography of aortic dissection. Am J Roentgenol 1983; 141: 157–161
Doroghazi RM, Slater EE, De Sanctis RW, Buckley MJ, Austen WG, Rosenthal S. Long-term survival of patients with treated aortic dissection. J Am Coll Cardiol 1984; 3: 1026–1034
De Bakey ME, McCollum CH, Crafor ES, Morris GC, Howell J, Noon GP, Lawrie G. Dissection and dissecting aneurysm of the aorta: twenty-year follow-up of five hundred and twenty-seven patients treated surgically. Surgery 1982; 6: 1118–1134
Cigarroa JE, Isselbacher EM, DeSanctis RW, Eagle KA. Diagnostic imaging in the evaluation of suspected aortic dissection. New Engl J Med 1993; 328: 35–43
Goodwin JD, Turley K, Herfkens RJ, Lipton MJ. Computed tomography for follow-up of chronic aortic dissection. Radiology 1981; 139: 655–660
Mathieu D, Keita K, Loisance D, Cachera JP, Rousseau M, Vasile N. Postoperative CT follow-up of aortic dissection. J Comput Assist Tomogr 1986; 10: 216–220
Yamaguchi T, Guthaner DF, Wexler L. Natural history of the false channel of type A aortic dissection after surgical repair: CT study. Radiology 1989; 170: 743–747
Mohr-Kahaly S, Erbel R, Renollet H, Wittlich N, Drexler M, Oelert H, Meyer J. Ambulatory follow-up of dissection by transesophageal two-dimensional and color-coded Doppler echocardiography. Circulation 1989; 80: 254–263
Di Segni M, Minardi G, Pucci E, Boccardi L, Mamone P, Pucci A, Benhar M, D'Alessandro LC, Giovannini E. Follow-up dei pazienti operati per dissezione aortica: valutazione con ecocardiografia transesofaea. G Ital Cardiol 1992; 22: 1179–1189
Roudaut RP, Marcaggi XL, Deville C, de Verbizier G, Dos Santos P, Fontan F, Dallocchio M. Value of transesophageal echocardiography combined with computed tomography for assessing repaired type A aortic dissection. Am J Cardiol 1992; 70: 1468–1476
Iliceto S, Ettorre G, Francioso G, Antonelli G, Biasco G, Rizzon P. Diagnosis of aneurysm of the thoracic aorta: comparison between two noninvasive techniques: two dimensional echocardiography and computed tomography. Eur Heart J 1984; 5: 545–555
Nienaber C, von Kodoitsch Y, Nicolas V, Siglow V, Piepho A, Brockhoff C, Hoschyk DH, Spielmann RP. The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med 1993; 328: 1–9
Nienaber CA, Spielmann RP, von Kodolitsch Y et al. Diagnosis of thoracic aortic dissection: magnetic resonance imaging versus transesophageal echocardiography. Circulation 1992; 85: 434–447
Erbel R, Bednarczyk I, Pop T, Todt M, Henrichs KJ, Brunier A, Thelen M, Meyer J. Detection of dissection of the aortic intima and media after angioplasty of coarctation of the aorta. Circulation 1990; 81: 805–814
Erbel R, Oelert H, Meyer J, Puth M, Mohr-Kahaly S, Hausmann D, Daniel W, Maffei S, Caruso A, Covino FE, Dialetto G, Iacono C, Cotrufo M, Baroni M, Terrazzi M, Fraser A, Taams M, Slavich G, Sutherland G, Roelandt J, Marcaggi X, for the European Cooperative Study Group on Echocardiography. Effect of medical and surgical therapy on aortic dissection evaluated by transesophageal echocardiography. Implications for prognosis and therapy. Circulation 1993; 87: 1604–1615
Theckdath M, Nanda NC. Two-dimensional and Doppler echocardiographic evaluation of aortic aneurysm and dissection. Am J Cardiol 1984; 54: 379–385
Iliceto S, Nanda NC, Rizzon P, Hsuing MC, Goyal RG, Amico A, Margherita M. Color Doppler evaluation of aortic dissection. Circulation 1987; 75: 748–755
Erbel R, Boerner N, Steller D, Brunier J, Thelen M, Pfeiffer C, Mohr-Kahaly S, Iversen S, Oelert H, Meyer J. Detection of aortic dissection by transesophageal echocardiography. Br Heart J 1987; 58: 45–51
Balla RS, Nanda NC, Gatewwod R, et al. Usefulness of transesophageal echocardiography in assessment of aortic dissection. Circulation 1991; 84: 1903–1914
Daniel WG et al. Left atrial spontaneous echo contrast in mitral valve disease: an indicator for an increased thromboembolic risk. J Am Coll Cardiol 1988; 11: 1204–1211
Black IW, Hopkins AP, Lee LC, Walsh WF. Left atrial spontaneous echocontrast: a clinical and echocardiographic analysis. J Am Coll Cardiol 1991; 18: 398–404
Mahony C, Sublett KL, Harrison MR. Resolution of spontaneous contrast with platelet disaggregatory therapy (trifluoperazine). Am J Cardiol 1989; 63: 1099–1100
Shellock FG, Curtis JS. MR imaging and biomedical implants, material and devices: an update review. Radiology 1991; 180: 541–550
Hamada S, Takamiya M, Kimura K, Imakita S, Nakaijma N, Naito H. Type A aortic dissection: evaluation with ultrafast CT. Radiology 1992; 183: 155–158
Clinton W. The Clinton health care plan. N Engl J Med 1992; 327 [11]: 804
Roelandt JR, Thomson IR, Vletter WB, Brommersma P, Bom N, Linker DT. Multiplane transesophageal echocardiography: latest evolution in an imaging revolution. J Am Soc Echocardiogr 1992; 5: 361–367
Redberg RF. Coronary flow by transesophageal Doppler echocardiography: do saccharide-based contrast agents sweeten the pot? J Am Coll Cardiol 1994; 23: 191–193
Author information
Authors and Affiliations
Additional information
This work was partially supported by a CNR grant on specialized program.
This article is accompanied by an Editorial comment written by Prof. Dr R. Erbel, which follows on pp. 137–138 in this issue.
Rights and permissions
About this article
Cite this article
Maffei, S., Baroni, M., Terrazzi, M. et al. Ambulatory follow-up of aortic dissection: comparison between computed tomography and biplane transesophageal echocardiography. Int J Cardiac Imag 12, 105–111 (1996). https://doi.org/10.1007/BF01880741
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01880741