Echocardiographic assessment of systolic and diastolic left ventricular function using an automatic boundary detection system

Correlation with established invasive and non invasive parameters

  • Articles
  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Systolic and diastolic left ventricular function was assessed using an echocardiographic automatic boundary detection system (ABD) in 50 unselected patients undergoing left cardiac catheterisation. Automatic boundary detection system derived parameters (fractional area change [FAC], peak positive rate of area change [+dA/dt] and peak negative rate of area change [−dA/dt]) were compared with invasively (left ventricular angiography and pressures) and non invasively (Doppler mitral filling velocities and isovolumic relaxation time) acquired conventional indices of ventricular function. Adequate detection of endocardial boundaries and subsequent measurements using the ABD system were achieved in 40/50 (80%) patients in the short axis parasternal view, in 41/50 (82%) in the apical four chamber view and in 34/50 (68%) in both views. For the whole group of patients the FAC (maximal left ventricular diastolic area — minimal left ventricular systolic area/maximal left ventricular diastolic area) estimated in the short axis view correlated with the angiographic ejection fraction (EF) measured in the right oblique projection (r=0.51, p<0.001). There was only a weak correlation of the FAC estimated in the apical four chamber view with the EF (r= 0.36, p<0.01). The mean FAC (mean value of the FAC in the short axis and apical four chamber views) correlated reasonably with the EF (r=0.62, p<0.0001). There was no correlation between ABD derived parameters and left ventricular end diastolic pressure (LVEDP) in these patients.

In a subgroup of patients with normal coronary arteries and left ventricular function (n = 17), although there was no correlation between EF and FAC, there was a strong positive correlation between FAC (apical four chamber and mean) and LVEDP (r=0.77, p<0.01 and r=0.87, p<0.01 respectively). No correlation was found in these patients between EF and LVEDP. In a further subgroup of patients with angiographically abnormal left ventricular function (EF<45%), there was a positive correlation between FAC (short axis, apical four chamber and mean) and EF (r=0.52, p<0.05, r=0.83, p<0.0001 and r=0.80, p<0.001 respectively) and a negative correlation between FAC (short axis and mean) and LVEDP (r=−0.52, p<0.05 and r=−0.60, p<0.01 respectively). There was also a negative correlation between LVEDP and EF in the same subgroup of patients (r=−0.65, p<0.01).

None of the ABD derived parameters correlated with non invasively acquired indices of diastolic ventricular function (peak early left ventricular diastolic filling blood velocity [Emax], peak late diastolic velocity [Amax], E/A ratio and isovolumic relaxation time [IVRT], but there was a consistent positive correlation between −dP/dt and + dA/dt estimated in the four chamber view (r=0.5, p<0.01, all patients).

Therefore, although ABD derived parameters cannot be used in an interchangeable way with ejection fraction, they do provide a rapid, bedside method for the assessment of left ventricular function. FAC and dA/dt do appear to reflect left ventricular performance both in patients with normal ventricles and in patients with impaired left ventricular function.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Shah PM, Crawford M, DeMaria, et al. Recommendation for quantitation of the left ventricle by two dimensional echocar-diography. J Am Soc Echo 1989; 2: 358–62.

    Google Scholar 

  2. Monaghan MJ, Thomas MR, Michalis LK, Jewitt DE. Real time echocardiographic analysis of ventricular function by automatic boundary detection (abstract). Br Heart J 1992; 68: 143.

    Google Scholar 

  3. Sharma MK, Kieslo RA, Fleagle SR, et al. Real time, on-line echocardiographic measurement of LV function using an automated border detection system (abstract). Circulation 1991; 84 (Suppl II): II-585.

    Google Scholar 

  4. Perez JE, Waggoner BA, Barzilai H, Melton HE, Miller JG, Sobel BE. On line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992; 19: 313–20.

    Google Scholar 

  5. Pinto FJ, Siegel LC, Kreitzman TR, Davidson R, Popp RL, Schnittger I. On-line estimation of cardiac output with a new automated edge detection system using transoesophageal echocardiography: Comparison with thermodilution (abstract). Circulation 1991; 84 (Suppl II): II-585.

    Google Scholar 

  6. Gorcsan J III, Pinsky MR. On-line determination of variations in stroke volume by echocardiographic automated border detection: In vivo validation (abstract). Circulation 1991; 84 (Suppl II): II-586.

    Google Scholar 

  7. Fisher JP, McKay RG, Mikan JS, et al. A comparison of echocardiographic methods of evaluating regional LV systolic function: Fractional area change vs the end-systolic pressure area relation. Circulation 1992; 86 (Suppl I): I-261.

    Google Scholar 

  8. Gorscan J III, Schulman DS, Koch L, Thornton J, Follansbee WP. Echocardiographic automated border detection derived left ventricular ejection fraction: Comparison with radionuclide angiography (abstract). Circulation 1991; 84 (Suppl II): II-585.

    Google Scholar 

  9. Foley DA, Seward JB, Tajik J. Assessment of left ventricular diastolic function with a new automated echocardiographic border detection system: Comparison with Doppler (abstract). J Am Coll Cardiol 1992; 19 (A): 261A.

    Google Scholar 

  10. Appleton CP, Hatle L, Popp RL. Relation of transmitral flow velocity patterns to left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocar-diographic study. J Am Coll Cardiol 1988; 12: 426–39.

    Google Scholar 

  11. Greene DG, Carlisle R, Grant C, Bunnell IL. Estimation of left ventricular volume by one-plane cineangiography. Circulation 1967; 35: 61.

    Google Scholar 

  12. Sandier H, Dodge HT. The use of single plane angiocardiograms for the calculation of left ventricular volume in man. Am Heart J 1968; 75: 325.

    Google Scholar 

  13. Kennedy JW, Trenholme SE, Kasser IS. Left ventricular volume and mass from single plane cineangiocardiogram. A comparison of anteroposterior and right anterior oblique methods. Am Heart J 1970; 80: 343.

    Google Scholar 

  14. Tutt LK, Kopelen HA, Vukovic JS, Soto JG, Zoghbl WA, Quinonew MA. Acoustic quantification of results between technologists in a non-selected cardiac population. Circulation 1993; 86 (Suppl I): I-264.

    Google Scholar 

  15. Martin PR. Real time ultrasound quantification of ventricular function: Has the eyeball been replaced or will the subjective become objective? J Am Coll Cardiol 1992; 19: 321–3.

    Google Scholar 

  16. Braunwald E. Heart disease: A textbook of cardiovascular medicine. Philadelphia: W.B. Saunders Co, 1992: 419–43.

    Google Scholar 

  17. Zimpfer M, Vatner SF. Effects of acute increases in left ventricular preload on indices of myocardial function in conscious, unrestrained and intact, tranquilised babboons. J Clin Invest 1981; 64: 430.

    Google Scholar 

  18. Nixon JV, Murray RG, Leonard PD, et al. Effect of large variations in preload on left ventricular performance characteristic in normal subjects. Circulation 1982; 65: 689.

    Google Scholar 

  19. Sarnoff SJ, Mitchell JH. Control of function of heart. In: Hamilton WF, Dow P, (eds). Handbook of physiology. Washington DC: American Physiological Society, 1962: 389–532.

    Google Scholar 

  20. Lambert CR Jr, Nichols WW, Pepine CJ. Indices of ventricular contractile state: Comparative sensitivity and specificity. Am Heart J 1983; 106: 136.

    Google Scholar 

  21. Lew WY. Evaluation of left ventricular diastolic function. Circulation 1989; 79: 1393–97.

    Google Scholar 

  22. Nishimura RA, Abel MD, Hatle LK, Tajik AJ. Assessment of diastolic function of the heart: Background and current applications of Doppler echocardiography. Mayo Clin Proc 1989; 64: 181–204.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Michalis, L.K., Thomas, M.R., Jewitt, D.E. et al. Echocardiographic assessment of systolic and diastolic left ventricular function using an automatic boundary detection system. Int J Cardiac Imag 11, 71–80 (1995). https://doi.org/10.1007/BF01844704

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01844704

Key words

Navigation