The technique of direct multiplanar high resolution CT of the temporal bone

  • I. Computed tomography
  • Published:
Neurosurgical Review Aims and scope Submit manuscript

Summary

The technique of direct multiplanar high resolution CT opens new possibilities for detecting even the smallest lesions of the central nervous system and its coverings.

The prerequisites are:

  1. 1.

    Submillimetre spatial resolution.

  2. 2.

    Thin slice thickness collimation.

  3. 3.

    Sufficient radiation dose to keep the noise in the image around about 1%.

  4. 4.

    No waiting time between scans other than short reconstruction times, or use of rapid sequence scan procedures.

  5. 5.

    Possibility to position patients and immobilize them for direct scanning of coronal and sagittal planes without significantly reducing the patient's comfort.

  6. 6.

    Possibility of using optional algorithms which improve spatial resolution further (Macro View) in order to bring out very fine details.

This article describes the technique we have used in order to fulfil these prerequisites and also gives a few results relating to the imaging of the facial nerve canal.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bluemm, R. G.: Direct sagittal (positional) computed tomography of the head. Neuroradiology 22 (1982) 199–201

    Google Scholar 

  2. Chakeres, D. W., P. K. Spiegel: A systematic technique for comprehensive evaluation of the temporal bone by computed tomography. Radiology 146 (1983) 97–106

    Google Scholar 

  3. Claus, E., S. F. Le Mahieu, D. Ernould: The most used otoradiological projections. J. Belge Radiol. 63 (1980) 183–203

    Google Scholar 

  4. De Smedt, E., R. Potvliege, B. Pimontel-Appel, et al.: High resolution CT scan of the temporal bone, a preliminary report. J. Belge Radiol. 63 (1980) 205–212

    Google Scholar 

  5. Hanafee, W. N., A. A. Mancuso, H. A. Jenkins, et al.: Computerized tomography scanning of the temporal bone. Ann. Otol. Rhinol. Laryngol. 88 (1979) 721–728

    Google Scholar 

  6. Littleton, J. T., K. A. Shaffer, W. P. Callahan, et al.: Temporal bone: Comparison of pluridirectional tomography and high resolution computed tomography. AJR 137 (1981) 835–845

    Google Scholar 

  7. Mafee, M. F., A. Kumar, D. A. Yannias, et al.: Computed Tomography of the middle ear in the evaluation of cholesteatomas and other soft tissue masses: comparison with pluridirectional tomography. Radiology 148 (1983) 465–472

    Google Scholar 

  8. Peyster, R. G.: Ultra-thin CT imaging: skinny can be beautiful. Diagn. Imaging (Sept. 1983) 89–91

  9. Pinto, R. S., I. I. Kricheff, R. T. Bergeron, et al.: Small acoustic neuromas: Detection by high resolution gas CT cisternography. AJR 139 (1982) 129–132

    Google Scholar 

  10. Rettinger, G., W. Kalender, F. Henschke: Hochauflösungs-Computertomographie des Felsenbeines. Computertomographie 1 (1981) 109–116

    Google Scholar 

  11. Russell, E. J., M. Koslow, P. Lasjaunias, et al.: Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography. Neuroradiology 22 (1982) 185–191

    Google Scholar 

  12. Shaffer, K. A., V. M. Haughton, C. R. Wilson: High resolution computed tomography of the temporal bone. Radiology 134 (1980) 409–414

    Google Scholar 

  13. Shaffer, K. A., D. J. Volz, V. M. Haughton: Manipulation of CT data for temporal-bone imaging. Radiology 137 (1980) 825–829

    Google Scholar 

  14. Swartz, J. D.: High resolution computed tomography of the middle ear and mastoid. Part 1: Normal radioanatomy including normal variations. Radiology 148 (1983) 449–454

    Google Scholar 

  15. Taylor, S.: The petrous temporal bone (including the cerebellopontine angle). Radiol. Cl. North Am. 20 No. 1 (1982) 67–86

    Google Scholar 

  16. Turski, P., D. Norman, J. De Groot, et al.: High resolution CT of the petrous bone: direct vs. reformatted images. AJNR 31 (1982) 391–394

    Google Scholar 

  17. Virapongse, C., S. L. G. Rothman, C. Sasaki, et al.: The role of high resolution computed tomography in evaluating disease of the middle ear. J. Comput. Assist. Tomogr. 6 (1982) 711–720

    Google Scholar 

  18. Virapongse, C., M. Sarwar, E. L. Kier, et al.: Temporal bone disease: a comparison between high resolution computed tomography and pluridirectional tomography. Radiology 147 (1983) 743–748

    Google Scholar 

  19. Vijverberg, G. P., F. W. Zonneveld: The relationship between slice-thickness and image quality in CT. Scientific exhibit presented at the Vth European Congress of Radiology, Bordeaux, France, Sept 5–10, 1983. Medicamundi 29 (1984) 104–117.

    Google Scholar 

  20. Zonneveld, F. W.: Variable scanner geometry for optimal resolution. Int. Symp. and Course on Comput. Tomography, Miami Beach, FA, U.S.A., March 19–24, 1978, paper 151. Published in: Medita (Sonderheft 1) (1978) 41–46

  21. Zonneveld, F. W.: The value of non-reconstructive multiplanar CT for the evaluation of the petrous bone. Neuroradiology 25 (1983) 1–10

    Google Scholar 

  22. Zonneveld, F. W., P. F. G. M. van Waes, H. Damsma, et al.: Direct multiplanar computed tomography of the petrous bone. Radiographics 3 (1983) 400–449

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zonneveld, F.W. The technique of direct multiplanar high resolution CT of the temporal bone. Neurosurg. Rev. 8, 5–13 (1985). https://doi.org/10.1007/BF01744873

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01744873

Keywords

Navigation