Abstract
In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during “in vitro” studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with “new” HMEs and after 12 h of continuous use.
Article PDF
Similar content being viewed by others
References
Tausk H, Miller R, Roberts R (1976) Maintenance of body temperature by heated humidification. Anesth Analg 55:719–722
Chalon J, Loew D, Malebranche J (1972) Effects of dry anesthetic gases on tracheobronchial ciliated epithelium. Anesthesiology 37:338–341
Marfatia S, Donahoe PK, Hendren WH (1975) Effects of dry and humidified gases on the respiratory epithelium in rabbits. J Pediatr Surg 10:583–587
Cristopher KL, Saravolatz LD, Bush TL, Conway WA (1983) The potential role of respiratory therapy equipment in cross-infection. Am Rev Respir Dis 128:271–275
Mebius CA (1983) Comparative evaluation of disposable humidifiers. Acta Anaesthesiol Scand 27:403–409
Bethune DW, Shelley MP (1985) Hydrophobic versus hygroscopic heat-moisture exchangers. Anesthesia 40:210–211
Chalon J, Marham JP, Ali MM, Ramanathan S, Turudorf H (1984) The Pall Ultipor breathing circuit filters—an efficient heat and moisture exchanger. Anesth Analg 1:285–294
Shelley M, Bethune DW, Latimer RD (1986) A comparison of five heat and moisture exchangers. Anaesthesia 41:527–532
Turtle MJ, Ilsley AH, Rutten AJ, Runcinam WB (1987) An evaluation of six disposable heat moisture exchangers. Anaesth Intensive Care 15:317–322
Ploysongsang Y, Branson R, Rashkin MC, Hurst JM (1988) Pressure flow characteristics of commonly used heat moisture exchangers. Am Rev Respir Dis 138:675–678
Pepe PE, Marini JJ (1982) Occult positive end expiratory pressure in mechanically ventilated patients with airflow obstruction. Am Rev Respir Dis 125:166–170
Kimball WR, Leith DE, Robins AG (1982) Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease. Am Rev Respir Dis 126:991–995
Rossi A, Gottfried SB, Zocchi L, Higgs BD, Lennox S, Calverley PMA, Begin P, Grassino A, Milic-Emili J (1985) Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation: the effect of intrinsic positive end-expiratory pressure. Am Rev Respir Dis 131:672–677
Broseghini C, Brandolese R, Poggi R, Polese G, Manzin E, Milic-Emili J, Rossi A (1988) Respiratory mechanics during the first day of mechanical ventilation in patients with pulmonary oedema and chronic airway obstruction. Am Rev Respir Dis 138:355–361
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Conti, G., De Blasi, R.A., Rocco, M. et al. Effects of the heat-moisture exchangers on dynamic hyperinflation of mechanically ventilated COPD patients. Intensive Care Med 16, 441–443 (1990). https://doi.org/10.1007/BF01711222
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01711222