Abstract
Two pulse oximeters, the Nellcor N-100 and the Ohmeda 3700, were compared with arterial blood values and with each other in a clinical evaluation of performance. Three hundred twenty-nine simultaneously sampled blood/oximeter data pairs from use of both makes of pulse oximeters on each of 152 test subjects were included in the comparison analysis for each oximeter. Among the patients, disease type and severity and hospital location varied widely. Basic descriptive statistics and linear regression analysis were employed to facilitate comparison. Both oximeters displayed a statistically significant but clinically insignificant bias when compared with arterial blood oxyhemoglobin: −0.31 (P=0.023) and 0.59 (P=0.001) for the Ohmeda 3700 pulse oximeter and the Nellcor N-100 pulse oximeter, respectively. Relative to arterial blood oxyhemoglobin, the 95% tolerance intervals were +4.84 to −5.45 (10.3) for the Ohmeda 3700 and +6.94 to −5.76 (12.7) for the Nellcor N-100. Regressed against [oxyhemoglobin + carboxyhemoglobin + methemoglobin] as x, the Nellcor N-100 read y=0.85(x)+12.5,r=0.83,P<0.0001, and the Ohmeda 3700 read y=1.02(x)−5.3,r=0.86,P<0.0001.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Severinghaus JW, Honda Y. History of blood gas analysis. VII. Pulse oximetry. J Clin Monit 1987;3:135–138
Fanconi S, Doherty B, Edmonds JF, et al. Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension. J Pediatr 1985;107:362–366
Beyer WH, ed. Handbook of tables for probability and statistics. Cleveland: Chemical Rubber, 1974:138.
Nellcor, Incorporated. Instruction manual. Nellcor pulse oximeter model N-100. Hayward, CA: Nellcor, Inc., 1984
Ohmeda. Ohmeda Biox 3700 pulse oximeter operating/maintenance manual. Boulder, CO: Ohmeda, 1985
Mackenzie N. Comparison of a pulse oximeter with an ear oximeter and an in-vitro oximeter. J Clin Monit 1985;1:156–160
Nellcor, Incorporated. Technical note no. 2. Hayward, CA: Nellcor, Inc., 1984
Yelderman M, New W. Evaluation of pulse oximetry. Anesthesiology 1985;59:349–352
Shippy MB, Petterson MT, Whitman RA, Shivers CR. A clinical evaluation of the BTI Biox II ear oximeter. Respir Care 1984;29:730–735
Cecil WT, Petterson MT, Lamoonpun S, Rudolph CD. Clinical evaluation of the Ohmeda Biox IIA ear oximeter in the critical care environment. Respir Care 1985;30:179–183
Cecil WT, Morrison LS, Lamoonpun S. Clinical evaluation of the Ohmeda Biox III pulse oximeter: a comparison of finger and ear cuvettes. Respir Care 1985;30:840–845
Altman DG. Statistics and ethics in medical research. Vanalysing data. Br Med J 1980;281:1473–1475
Severinghaus JW. Discussion II. In: Payne JP, Severinghaus JW, eds. Pulse oximetry. London: Springer-Verlag 1986:45–53
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cecil, W.T., Thorpe, K.J., Fibuch, E.E. et al. A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters. J Clin Monitor Comput 4, 31–36 (1988). https://doi.org/10.1007/BF01618105
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01618105