Summary

A simple, low-risk method causing little stress to the patient is described for direct continuous pressure measurement (percutaneous catheterization of the brachial artery) and radiotelemetric transmission. It is demonstrated that this permits to record rapid blood pressure changes under various conditions, as well as to establish an exact everyday-like 24-hour blood pressure profile. The method seems appropriate for studies of blood pressure rhythm as well as for clinical pharmacological examinations. Compared with the common indirect measurement of blood pressure in supine and standing position, a „new dimension“ in the evaluation of blood pressure reactions may be open with the method presented.

Zusammenfassung

Es wird eine einfache, risikoarme, den Probanden nicht belastende Methode zur direkten kontinuierlichen blutdruckmessung und telemetrischen Übertragung beschrieben. An Hand typischer Anwendungsbeispiele läßt sich zeigen, daß mit dieser Methode sowohl die Erfassung rascher Blutdruckänderungen unter verschiedenen Bedingungen, als auch die genaue Registrierung eines „alltäglichen“ 24 Std-Blutdruckprofils möglich ist. Die Methode erscheint geeignet für grundlagen-bezogene Studien der Blutdruckrhythmik, wie für klinisch-pharmakologische Untersuchungsreihen. Verglichen mit herkömmlichen indirekten Messungen der Liege-und Steh-Blutdrucke könnte sich mit vorliegender Methode eine „neue Dimension“ in der Beurteilung des Blutdruckverhaltens eröffnen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Anschütz, F.: RR-Messung beim Erwachsenen. Diagnostik1, 97 (1968).

    Google Scholar 

  • Anschütz, F.: Über die Zuverlässigkeit der auskultatorisch ermittelten Blutdruckwerte unter körperlicher Belastung. Fortschr. Med.88, 1391 (1970).

    Google Scholar 

  • Anschütz, F., Drube, H. Ch.: Über den Fehler der auskultatorischen Blutdruckmessung nach Riva-Rocci/Korotkoff bei Kreislaufumstellungen. Verh. dtsch. Ges. Kreisl.-Forsch.20, 278 (1954).

    Google Scholar 

  • Ayman, D.: Arterial hypertension. New York, Oxford University Press 1948.

    Google Scholar 

  • Bachmann, K.: Drahtlose Blutdrucktelemetrie. In: Biotelemetrie, Sympos., Erlangen, 1968; S. 210. Stuttgart: Thieme 1970.

    Google Scholar 

  • Bachmann, K., Reichenbach, M., Graf, N., Heynen, H. P.: Direkte Blutdruckmessungen während sportlicher Belastung. Telemetrie von Blutdruck-und Herzfrequenz beim Reitsport. Med. Klin.63, 1882 (1968).

    Google Scholar 

  • Bachmann, K., Thebis, J.: Die drahtlose Übertragung kontinuierlicher, direkter Blutdruckmessungen. Z. Kreisl.-Forsch.56, 188 (1967).

    Google Scholar 

  • Bachmann, K., Thebis, J., Heynen, H. P., u. Graf, N.: Die drahtlose Blutdruckregistrierung unter physiologischen Belastungen. Verh. dtsch. Ges. Kreisl.-Forsch.33, 185 (1967).

    Google Scholar 

  • Bevan, A., Honour, A. J., Stott, F. G.: Zit. nach Pickering, G.: High blood pressure, 2nd ed., p. 56. London: Churchill Ltd. 1968.

    Google Scholar 

  • Bock, K. D.: Fehler und Gefahren bei der Hochdruckbehandlung. Dtsch. med. Wschr.88, 836 (1963).

    Google Scholar 

  • Bock, K. D.: Arterielle Hypertonie. In: Klinik der Gegenwart. München-Berlin: Urban & Schwarzenberg 1967.

    Google Scholar 

  • Bock, K. D.: Nochmals: Selbstkontrolle des Blutdrucks. Dtsch. Ärztebl.65, 1107 (1968).

    Google Scholar 

  • Bock, K. D.: Hochdruck, ein Leitfaden für die Praxis. Stuttgart: Thieme 1969.

    Google Scholar 

  • Bock, K. D., Kreuzenbeck, W.: Über die Tagesschwankungen des arteriellen Blutdrucks. In: Heilmeyer, L. und H. J. Holtmeier: Hochdruckforschung. Stuttgart: Thieme 1965.

    Google Scholar 

  • Grandjean, T., Enrico, J. F., Poli, S., Perret, C.: Souis intenscifs et surveillance automatique continuel de la pression artérielle. Press. méd.77, 571 (1969).

    Google Scholar 

  • Karlefors, T., Nilsen, R., Westling, H.: On the accuracy of indirect auscultatory blood pressure measurements during exercise. Acta med. scand., Suppl.,449, 81 (1966).

    Google Scholar 

  • Krönig, B., Klemeit, R., Witzel, U., Jahnecke, J.: Telemetrische Untersuchungen über diurnale Schwankungen der Blutdruckreaktion Hochdruckkranker auf Belastung und in der Orthostase. In Vorbereitung (1972c).

  • Krönig, B., Schwarz, W., Parade, D., Heinebrodt, E., Jahnecke J.: Einfluß von hochdosiertem Raubasin auf den Blutdruck des Menschen im Liegen, Stehen und Gehen. Herzkreisl.4, (1972a), im Druck.

  • Krönig, B., Schwarz, W., Parade, D., Jahnecke, J.: Blutdruckverhalten unter hohen Raubasindosen beim Menschen. Verh. dtsch. Ges. inn. Med.77, 1013 (1971).

    Google Scholar 

  • Krönig, B., Witzel, U., Klemeit, R., Jahnecke, J.: Telemetrische Langzeitmessungen zur pharmakologischen Beeinflußbarkeit des Belastungsblutdruckes Hochdruckkranker. In Vorbereitung (1972b).

  • Menzel, W.: Über labile und paroxysmale Hypertonie. Med. Welt12, 560 (1961).

    Google Scholar 

  • Parade, D., Krönig, B., Schwarz, W., Jahnecke, J.: Untersuchungen zur Beeinflussung der durch antihypertensive Pharmaka induzierten Orthostase mit Dihydroergotamin. Verh. dtsch. Ges. inn. Med.77, 113 (1971).

    Google Scholar 

  • Richardson, D. W., Honour, A. J., Fenton, G. W., Stott, F. H., Pickering, G. W.: Variation in arterial pressure throughout the day and night. Clin. Sci.26, 445 (1964).

    Google Scholar 

  • Richardson, D. W., Honour, A. J., Goodman, A. C.: Zit. nach Pickering, G.: High blood pressure, 2nd ed., p. 52. London: Churchill Ltd. 1968.

    Google Scholar 

  • Robertson, Ph. W., Hull, D. H., Klidjian, A., Dyson, M. L.: Renal artery anomalies and hypertension. Amer. Heart J.73, 296 (1967).

    Google Scholar 

  • Sack, H., Koll, J. F.: Ungewöhnliche Beobachtungen beim Phäochromocytom. Dtsch. med. Wschr.84, 733 (1959).

    Google Scholar 

  • Stollreiter, H.: Die physikalische Schlagvolumenbestimmung. Arch. Kreisl.-Forsch.16, 174 (1950).

    Google Scholar 

  • Sturm, jr., A.: Arterielle Hochdruckerkrankungen. Darmstadt: Steinkopff 1970.

    Google Scholar 

  • Wagner, H.: Über die Bedeutung der paroxysmalen Hypertonie für das Klimakterium der Frau. Klin. Wschr.34, 379 (1956).

    Google Scholar 

  • Zerzawy, R., Bachmann, K.: Anwendung neuer Halbleiterbauelemente für die Signalübertragung in der Blutdrucktelemetrie. In: Biotelemetrie, Sympos., Erlangen, 1968; S. 202. Stuttgart: Thieme 1970.

    Google Scholar 

  • Zülch, K. J., Hossmann, V.: Über die 24-Stunden-Rhythmik des menschlichen Blutdrucks. Dtsch. med. Wschr.92, 567 (1967).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Krönig, B., Parade, D., Schwarz, W. et al. Blutdrucktelemetrie beim Menschen mit der Mikrokathetermethode. Klin Wochenschr 50, 898–906 (1972). https://doi.org/10.1007/BF01487919

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01487919

Key words

Schlüsselwörter

Navigation