Abstract
The onset current of the helical instability of wall stabilized arcs can be determined by a theoretical model from a dimensionless function which is only dependent on the power input and a factor containing the gas properties and the arc conductance. The model describes the onset current of the instability in hydrogen and nitrogen as function of the tube diameter and of the pressure. Questions of restabilization are discussed.
Similar content being viewed by others
Literatur
Guillery, P.: In: W. Finkelnburg, Hochstromkohlebogen. Berlin-Göttingen-Heidelberg: Springer (1948)
Witkowski, S.: Z. Angew. Phys.11, 135 (1959)
Gaede, P.-J.: Z. Physik255, 40 (1972)
Steinberger, S.: Z. Physik223, 1 (1969)
Mentel, J.: Z. Naturforsch.26a, 526 (1971)
Plantikow, U.: Z. Physik227, 271 (1969)
Uhlenbusch, J.: Private Mitteilung
Kreutzberger, G.: Private Mitteilung
Ernst, K. A., Kopainsky, J., Maecker, H.: Erscheint demnächst
Schönauer, H.: Private Mitteilung
Siehe z.B. Vortmeyer, D.: Dimensionslose Gruppen, Dimensionsanalyse, Ähnlichkeit und Modelle. In: Encyklopädie der technischen Chemie, Bd. 1. 4. Auflage, S. 197–212. Weinheim/Bergstraße: Verlag Chemie (1972)
Maecker, H., Stäblein, H. G.: Proc. of the Xth Int. Conf. on Phen. in Ionized Gases, p. 178, Oxford 1971
Burhorn, F., Wienecke, R.: Z. Physik. Chem.215, 285 (1960)
Grier, N. T.: Nasa Technical Note, TND 186
Schreiber, P. W., Hunter, A. M., Benedetto, K. R.: Phys. Fluids14, 2696 (1971)
Wheeler, C. B.: J. Phys. D.: Appl. Phys.3, 1374 (1970)
Author information
Authors and Affiliations
Additional information
Herrn Prof. H. Maecker zum 60. Geburtstag gewidmet.
Rights and permissions
About this article
Cite this article
Ernst, K.A., Kopainsky, J. & Mentel, J. Der Einsatz der Wendelinstabilität in wandstabilisierten Lichtbögen. Z. Physik 265, 253–265 (1973). https://doi.org/10.1007/BF01397719
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF01397719