Abstract
We report a unique complication caused by the rod of a Harrington instrumentation device, which resulted in spinal stenosis and myelopathy. A literature review revealed no previous causes of direct spinal cord impingement caused by the rod of a Harrington device. In this case, years after the initial operation, the rod penetrated the lamina at the junction between a thoracic and a lumbar curve, causing spinal stenosis and myelopathy. We conclude that regular control of the position of the device and awareness of possible late neurological complications are necessary to identify such complications as early as possible.
Similar content being viewed by others
References
Been HD, Kalkman CJ, Traast HS, Ongerboer de Visser BW (1994) Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation. Spine 19:1402–1405
Bernard TN, Johnston CE, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. J Bone Joint Surg [Am] 65:1339–1345
Court-Brown CM, McMaster MJ (1982) Pseudarthrosis: a late cause of paraparesis after scoliosis surgery. J Bone Joint Surg [Am] 64:1246–1248
Curtis RS, Dickson JH, Harrington PR, Wendell DE (1979) Results of Harrington instrumentation in the treatment for severe scoliosis. Clin Orthop 144: 128–134
Dove J (1988) Segmental wiring for spinal deformity. A morbidity report. Spine 14:229–231
Eismont FJ, Simeone FA (1981) Bone overgrowth (hypertrophy) as a cause of late paraparesis after scoliosis fusion. J Bone Joint Surgery [Am] 63: 1016–1019
Guillemin F, Czomy A, Pouewl J (1991) Sciatic nerve compression by hematoma: case report of a late complication of Harrington's operation. Spine 16:237–239
Hales DD, Dawson EG, Delamarter R (1989) Late neurological complications of Harrington-Rod instrumentation. J Bone Joint Surg [Am] 71:1053–1057
Johnston CE, Happel LT, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating sublaminar segmental spinal instrumentation. J Bone Joint Surg [Am] 68: 556–563
Kornberg M, Herndon WA, Rechtine GR (1985) Lumbar nerve root compression at the site of hook insertion: late complication of Harrington rod instrumentation for scoliosis. Spine 10: 853–855
MacEwen GD, Bunnell WP, Sriram K (1975) Acute neurological complications in the treatment of scoliosis. J Bone Joint Surg [Am] 57:404–408
Michel CR, Lalain JJ (1985) Late results of Harrington's operation. Spine 10:414–419
Moskowitz A, Moe JH, Winter RB, Binner H (1980) Long-term follow-up of scoliosis fusion. J Bone Joint Surg [Am] 62:364–375
Savini R, Di Silvestre M, Gargiulo G (1990) Late paraparesis due to pseudarthrosis after posterior spinal fusion. J Spine Disord 3:427–432
Schlenzka D, Poussa M, Muschik M (1993) Operative treatment of adolescent idiopathic thoracic scoliosis. Clin Orthop 297:155–160
Thompson GH, Wilber RG, Shaffer JW, Scoles PV, Nash CL (1985) Segmental spinal instrumentation in idiopathic scoliosis. A preliminary report. Spine 10:623–630
Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL (1984) Postoperative neurological deficits in segmental spinal instrumentation. J Bone Joint Surg [Am] 66:1178–1187
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Krödel, A., Rehmet, J.C. & Hamburger, C. Spinal cord compression caused by the rod of a Harrington instrumentation device: A late complication in scoliosis surgery. Eur Spine J 6, 208–210 (1997). https://doi.org/10.1007/BF01301439
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01301439