Skip to main content

Advertisement

Log in

Technetium-99mL,l-ethylenedicysteine clearance and correlation with iodine-125 orthoiodohippurate for the determination of effective renal plasma flow

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Technetium-99mL,l-ethylenedicysteine (99mTcL,l-EC) is a new renal tubular tracer that allows the determination of the effective renal plasma flow (ERPF). The aim of this study was to derive simplified methods for the estimation of99mTc-L,l-EC clearance using one or two plasma samples after bolus injection. Fifty-nine multiple plasma dual-tracer samples (nine samples from 5 to 120 min after injection) were obtained after injection of kit-formulated99mTc-L,l-EC and iodine-125 orthoiodohippurate (01H). The studies were performed in 25 stable and 24 unstable transplant recipients, in five patients with renal insufficiency (four on chronic haemodialysis) and in five normal volunteers. This allowed a wide range of renal function values to be covered, with ERPF (estimated by 01H clearance) ranging from 25.4 to 604.0 ml/min. The reference99mTc-L,l-EC clearance, as calculated from the multisample model, could be estimated from two samples at 15 and 90 min with an error of 11.3 ml/min and from one sample at 90 min with an error of 17.8 ml/min. Using appropriate linear regression analysis, ERPF could be estimated by the two- and one sample99mTc-L,l-EC clearance with an error of 24.2 and 22.8 ml/min, respectively. In conclusion,99mTc-L,l-EC clearance can be accurately estimated by simplified one or two-sample methods. Moreover, these methods can be used to estimate ERPF with an error that remains acceptable for clinical purposes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Stoffel M, Jamar F, Van Nerom C, Verbruggen A, Mourad M, Leners N, Squifflet J-P, Beckers C. Evaluation of technetium99m-L,l-EC in renal transplant recipients: a comparative study with technetium-99m-MAG3 and iodine-125-01H.J Nucl Med 1994; 35: 1951–1958.

    Google Scholar 

  2. Gupta NK, Bomanji JB, Waddington W, Lui D, Costa DC, Verbruggen AM, Ell PJ. Technetium-99m-L,l-ethylenedicys-teine scintigraphy in patients with renal disorders.Eur J Nucl Med 1995; 22: 617–624.

    Google Scholar 

  3. Kabasakal L, Atay S, Vural VA, Ozker K, Sönmezoglu K, Demir M, Uslu I, Isitman AT, Onsel C. Evaluation of technetium-99m-ethylenedicysteine in renal disorders and determination of extraction ratio.J Nucl Med 1995; 36: 1398–1403.

    Google Scholar 

  4. Verbruggen AM, Nosco DL, Van Nerom CG, Bormans GM, Adriaens PJ, De Roo MJ. Technetium-99m-L,l-ethylenedicys-teine: a renal imaging agent. I. Labeling and evaluation in animals. J Nucl Med 1992; 33: 551–557.

    Google Scholar 

  5. Levey AS, Perrone RD, Madias NE. Serum creatinine and renal function. Ann Rev Med 1988; 39: 465–490.

    Google Scholar 

  6. Sapirstein LA, Vidt DG, Mandel MJ, Hanusek G. Volumes of distribution and clearances of intravenously injected creatinine in the dog. Ani J Physiol 1955; 181: 330–336.

    Google Scholar 

  7. Russell CD, Dubovsky EV, Scott JW. Estimation of ERPF in adults from plasma clearance of 1311-hippuran using a single injection and one or two plasma samples.Nucl Med Biol 1989; 16: 381–383.

    Google Scholar 

  8. Tauxe WN, Maher FT, Taylor WE Effective renal plasma flow: estimation from theoretical volumes of distribution of intravenously injected1311-orthoiodohippurate.Mayo Clin Proc 1971; 46: 524–531.

    Google Scholar 

  9. Tauxe WN, Dubovsky EV Kidd T, Diaz F, Smith LR. New formulas for the calculation of effective renal plasma flow.Eur J Nucl Med 1982; 7: 51–54.

    Google Scholar 

  10. Phillips AN, Thompson SG, Pocock SJ. Prognostic scores for detecting a high risk group: estimating the sensitivity when applied to new data.Stat Med 1990; 9: 1189–1198.

    Google Scholar 

  11. Russell CD, Taylor A, Eshima D. Estimation of technetium99m-MAG3 plasma clearance in adults from one or two blood samples.J Nucl Med 1989; 30: 1955–1959.

    Google Scholar 

  12. Müller-Suur R, Magnusson G, Bois-Svensson I, Jansson B. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample.Eur J Nucl Med 1991; 18: 28–31.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stoffel, M., Jamar, F., Van Nerom, C. et al. Technetium-99mL,l-ethylenedicysteine clearance and correlation with iodine-125 orthoiodohippurate for the determination of effective renal plasma flow. Eur J Nucl Med 23, 365–370 (1996). https://doi.org/10.1007/BF01247362

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01247362

Key words

Navigation