Flow quantitation by contrast echocardiography

Effects of intervening tissue and of the angle of incidence between flow and ultrasonic beam

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

The combination of a standardized echographic contrast agent with the analysis of the ultrasonic radio frequency (RF) signal allowedin vitro flow quantitation in a circulation model. The purpose of this study was to investigate both the effects of biological tissues, intervening between probe and insonated structure, and the effects of the angle of incidence between flow and ultrasonic beam on RF flow quantitation. Thus, the contrast agent SHU 454 was intravenously injected (0.4 ml) as a bolus into a circulation model, at variable flow rates, while keeping the pressure and volume of the vessel constant. Injections were performed with saline interposed between probe and vessel and after the addition of the subcutaneous tissue of a pig; injections were also performed using the probe normal to the flow and with an angle of incidence of 45°. Echographic data were recorded by a mechanical sector scanner, capable of sampling the RF signal from a region of interest positioned in the center of the vein. Contrast echo time-intensity curves were generated. As expected, both peak intensity and the area under the curves decreased with intervening tissue (− 58 and − 70% of baseline values, respectively, p<0.001). Surprisingly, mean transit time also decreased with intervening tissue (from 1.12±0.25 seconds with saline, to 0.92±0.13 seconds with tissue, p<0.001), thus producing a systematic overestimation of flow (21% on the average). To compensate for signal attenuation, contrast injections were repeated in the presence of tissue after increasing the electronic signal amplification (10 dB), and transit time did not significantly differ from control. Moreover, mean transit time was slightly shorter with an angle of 45° (1.03 ° 0.19 seconds) than with an angle of 90° (1.12±0.25 seconds, p<0.05). However, when the data collected with both angles of incidence were plotted together, the correlation with flow remained very close (r=0.94). In conclusion: intervening tissue influences flow quantitation by contrast echocardiography: these modifications can be compensated for by increasing the electronic signal amplification; the angle of incidence between flow and ultrasonic beam also influences flow quantitation: however, this influence is trivial, and can be neglected for practical purposes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

RF:

radio frequency

References

  1. Rovai D, Lombardi M, Mazzarisi A, Landini L, Taddei L, Distance A, Benassi A, L'Abbate A. Flow quantitation by radio frequency analysis of contrast echocardiography. Int J Cardiac Imaging 1993; 9: 7–19 (this issue).

    Google Scholar 

  2. Cohen RD, Mottley JG, Miller JG, Kurnik PB, Sobel BE. Detection of ischemic myocardiumin vivo through the chest wall by quantitative ultrasonic tissue characterization. Am J Cardiol 1982; 50: 838–43.

    Google Scholar 

  3. Landini L, Mazzarisi A, Iracà D, Salvatori M, Benassi A. One-line two-dimensional evaluation of ultrasonic integrated backscatter. J Biomed Eng 1987; 9: 341–4.

    Google Scholar 

  4. Miller JG, Perez JE, Sobel BE. Ultrasonic characterization of myocardium. Prog Cardiovasc Dis 1985; 28: 85–110.

    Google Scholar 

  5. Smith MD, Kwan OL, Reiser J, DeMaria AN. Superior Intensity and reproducibility of SHU-454, a new right heart contrast agent. J Am Coll Cardiol 1984; 3: 992–8.

    Google Scholar 

  6. Rovai D, Lombardi M, Cini G, Morales MA, Colonna M, Becheli G, Marino P, Zanolla L, Prioli MA, Nicolosi GL, Pavan D, Zanuttini D, Iliceto S, Izzi M, Rizzon P, L'Abbate A. Echocardiographic Contrast Imaging of the Human Right Heart. A multicenter study of the efficacy, safety and reproducibility of intravenous SHU-454. J Clin Ultr 1991; 19: 523–30.

    Google Scholar 

  7. Miller JG, Yuhas DE, Mimbs JW, Kierker SB, Busse LJ, Laterra JJ, Weiss AN, Sobel BE. Correlation between biochemical and ultrasonic indices of myocardial injury. Proc IEEE Ultrasonics Symp, vol 76 CH1 120-5SU, 1976, 33–43.

  8. Miller JG, Pérez JE, Mottley JG, Madaras EI, Johnston PH, Blodgett ED, Thomas LJ, Sobel BE. Myocardial tissue characterization: an approach based on quantitative backscatter and attenuation. Proc IEEE Ultrasonic Symp, vol 83 CH1947-1,1983; 782–93.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rovai, D., Lombardi, M., Taddei, L. et al. Flow quantitation by contrast echocardiography. Int J Cardiac Imag 9, 21–27 (1993). https://doi.org/10.1007/BF01142929

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01142929

Key words

Navigation