Abstract
A new optical sensor for respiratory rate monitoring was simultaneously compared with an acoustic sensor and a transthoracic impedance plethysmograph during normoventilation in the respiratory rate range of 9–17 breaths per minute. The response characteristics of the optical sensor were then measured during simulation of central apnoea and tachypnoea. Visual observation was chosen as the reference method for monitoring the respiratory rate. The measurements were performed in ten healthy volunteers and the respiratory signals recorded on an analogue tape and strip-chart recorder and analysed off-line. The response characteristics of the fibre optic sensor corresponded well with those of the acoustic sensor and impedance plethysmograph. All three methods responded rapidly to an apnoeic event.
Similar content being viewed by others
References
Vegfors M, Cederholm I, Lennmarken C, Löfström JB. Should oxygen be administered after laparoscopy in healthy patients? Acta Anaesthesiol Scand 1988; 32: 350–2.
Rosenberg J, Pedersen MH, Gebuhr P, Kehlet H. Effect of oxygen therapy on late postoperative episodic and constant hypoxaemia. Br J Anaesth 68: 18–22.
Karayan J, Lacoste L, Fusciardi J. Postoperative Apnea in a full-term infant. Anesthesiology 1991; 75: 375.
Cote CJ, Kelly DH. Postoperative apnoea in a full term infant with a demonstrable respiratory pattern abnormality. Anesthesiology 1990; 72: 559–61.
Cox R, Goresky G. Life-threatening apnea following spinal anesthesia in former premature infants. Anesthesiology 1990; 73: 345–7.
Allison RD, Holmes EL, Nyboer J. Volumetric dynamics of respiration as measured by electrical impedance plethysmograph. J Appl Phys 1964; 19: 166–73.
Ashutosh K, Gilbert R, Auchincloss JH, Erlebacher J, Peppi D. Impedance pneumograph and magnetometer methods for monitoring tidal volume. J Appl Phys 1974; 37: 964–6.
Hamilton LH, Beard JD, Carmean RE, Kory RC. An electrical impedance ventilometer to quantitate tidal volume and ventilation. Med Res Eng 1967; 6: 11–6.
Lentz G, Heipertz W. Capnometry for continuous postoperative monitoring of nonintubated, spontaneously breathing patients. J Clin Monit 1991; 7: 245–8.
Roy J, McNulty S, Torjman M. An improved nasal prong apparatus for end-tidal carbon dioxide monitoring in awake, sedated patients. J Clin Monit 1991; 7: 249–52.
Henneberg S, Hök B, Wiklund L, Sjödin G. Remote auscultatory patient monitoring during magnetic resonance imaging. J Clin Monit 1992; 8: 37–43.
Hök B. Microphone design for bio-acoustic signals with suppression of noise and artifacts. Sensors and Actuators 1991; A 25–27: 527–33.
Hök B, Wiklund L, Henneberg S. A new respiratory rate monitor: Development and initial clinical experience. Int J Clin Monit Comp 1993; 10: 97–103.
Lindberg L-G, Ugnell H, Öberg P. Monitoring of respiratory-and heart rates using a fibre optic sensor. Med & Biol Eng & Comput 1992; 30: 533–7.
Vegfors M, Ugnell H, Hök B, Öberg PA, Lennmarken C. Experimental evaluation of two new sensors for respiratory rate monitoring. Physiol Meas 1993; 14: 171–181.
Born M, Wulf E. Principles of optics. Pergamon Press, Oxford, Great Britain, 1975.
Pettersson H, Öberg PA. A new fibre-optic sensor for respiratory rate monitoring. IXth Nordic Meeting on Medical and Biological Engineering, June 13–16, 1993, Lund, Sweden.
Tyler IL, Tantisira B, Winter PM, Motoyama EK. Continuous monitoring of arterial oxygen saturation with pulse oximetry during transfer to the recovery room. Anesth Analg 1985; 64: 1108–12.
Jense HG, Dubin SA, Silverstein PI, O'Leary-Escolas U. Effect of obesity on safe duration of apnea in anesthetized humans. Anesth Analg 1991; 72: 89–93.
Olsson T, Victorin L. Transthoracic Impedance, with special reference to newborn infants and the ratio air-to-fluid in the lungs. Acta Paediat Scand 1970; Suppl 207.
Kurth CD, LeBard SE. Association of postoperative apnea, airway obstruction, and hypoxemia in former premature infants. Anesthesiology 1991; 75: 22–6.
Yellowlees IH. Fibre optic sensors in clinical measurement. Br J Anaesth 1991; 67: 100–5.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vegfors, M., Lindberg, LG., Pettersson, H. et al. Presentation and evaluation of a new optical sensor for respiratory rate monitoring. J Clin Monit Comput 11, 151–156 (1994). https://doi.org/10.1007/BF01132363
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01132363