Skip to main content
Log in

Zur Stabilität hochverdünnter Multielement-Eichstandardlösungen — Erfahrungen mit ICP-MS

On the stability of highly diluted multielement calibration solutions — experiences with ICP-MS

  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

The long term stability of self prepared multielement calibration solutions, which is of fundamental importance in ultra trace element analysis with ICP-MS, has been tested. Solutions with element concentrations of 10 ppb, 50 ppb, 100 ppb and 500 ppb in different aqueous matrices have been analyzed immediately after preparation and after 1, 3, 10, and 30 days of stockage in usual glass vials. For analysis with a VG Plasmaquad, the pH of all solutions was adjusted to ca. 1. The results showed that even very low element concentrations of the majority of elements investigated in this study remained stable in acidic aqueous solutions over a period of 30 days. For boron, silver, gold, and tantalum significant changes of the initial concentrations have been observed dependent on stockage time. Decrease of element concentrations is due to adsorption on the surface of the glass vials and probably to photochemical oxidation. A considerable increase of the concentrations of all investigated boron-containing solutions even after a short stockage time is due to mobilization of boron from the glass of the vials. However, adsorption effects are of insignificant importance even for critical elements such as B, Br, I, Pb, and are largely dependent on the pH of the diluted solutions. Solutions with concentrations of a large number of elements in the range even below 1 ppm can be stocked as multielement standards for 30 days, if the pH of the solutions is not higher than 1.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Schweitzer GK, Stein BR, Jackson WM (1953) J Am Chem Soc 75:793

    Google Scholar 

  2. Schweitzer GK, Jackson WM (1954) J Am Chem Soc 76:941

    Google Scholar 

  3. Starik IJE (1963) Grundlagen der Radiochemie. Akademie-Verlag, Berlin

    Google Scholar 

  4. Tölg G (1975) In: Svehla G (ed) Wilson & Wilson's comprehensive analytical chemistry, vol 3, chapt 1. Oxford University Press, Oxford

    Google Scholar 

  5. Tölg G (1972) Talanta 19:1489

    Google Scholar 

  6. Robertson DE (1968) Anal Chim Acta 42:533

    Google Scholar 

  7. Robertson DE (1968) Anal Chem 40:1067

    Google Scholar 

  8. Schönfeld T, Broda E (1951) Microchim Acta 36/37:537

    Google Scholar 

  9. West FK, West PW, Iddings FA (1966) Anal Chem 38:1566

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Puchelt, H., Nöltner, T. Zur Stabilität hochverdünnter Multielement-Eichstandardlösungen — Erfahrungen mit ICP-MS. Z. Anal. Chem. 331, 216–219 (1988). https://doi.org/10.1007/BF01105171

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01105171

Navigation