Abstract
A neutron yield of } 5×105 D-D neutrons/discharge was obtained when 0.1 KJ of energy was pumped into a plasma focus of Mather type. The neutron yield was measured by a high sensitivity silver activation counter. The results are compared with those of other laboratories and it is found that neutron yield scales asE 1.73 orI 4.29 in the 0.1–500 KJ region.
Similar content being viewed by others
References
J.W.Mather: InMethods of Experimental Physics, Vol. 9, ed. by R.H.Lovberg, H.R.Griem (Academic Press, New York 1971) p. 187
L.Michel, K.H.Schonbach, H.Fischer: Appl. Phys. Lett.25, 547 (1974)
Original work by H.Rapp is unpublished, this figure is taken from [2]
O.Zucker, W.Bostick, R.Gullickson, J.Long, J.Luce, H.Sahlin: Proc. of the Intern. Conf. on Radiation Test Facilities for the CRT Surfaces and Material Program, Argonne National Laboratory Report No. ANL/CTR-75-4, 483 (1975)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Shyam, A., Srinivasan, M. Neutron emission from a 100 joule plasma focus. Appl. Phys. 17, 425–426 (1978). https://doi.org/10.1007/BF00886218
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00886218