Abstract
High resolution electron microscopy (HREM) has been used to study dispersed Pt clusters in NaY- and USY-zeolites. All the samples contained 0.8% Pt and were reduced at temperatures of 300 ° C, 500 ° C and 650 ° C. The size of the Pt clusters ranged from a few å up to ∼ 30 å. When the incident electron beam was sufficiently strong, it caused some of the extremely small metal clusters to sinter. This was usually accompanied by zeolite damage. This in-situ sintering must be taken into consideration when interpreting the particle size distribution results obtained solely by TEM, especially for particles that are smaller than 10 å. The minimum phase contrast imaging condition is demonstrated to be more appropriate than optimum defocus for detecting the extremely small Pt clusters inside the zeolite structures.
Similar content being viewed by others
References
E.J. Demmel, A.D. Perrella, W.A. Stover and J.P. Shambaugh, Oil Gas J. 64 (1966) 178.
T.R. Felthouse and J.A. Murphy, J. Catal. 98 (1986) 411.
M. Boudart, M.G. Samant and R. Ryoo, Ultramicroscopy 20 (1986) 125.
D.W. Breck,Zeolite Molecular Sieves (Wiley, New York, 1974) pp. 92–97.
I.Y. Chan, R. Csencsits, M.A. O'Keefe and R. Gronsky, J. Catal. 103 (1987) 466.
N.I. Jaeger, P. Ryder and G. Schulz-Ekloff, Stud. Surf. Sci. Catal. 18 (1984) 299.
L.A. Bursill, E.A. Lodge and J.M. Thomas, Nature (London), 286 (1980) 111.
L.A. Bursill, E.A. Lodge and J.M. Thomas, J. Phys. Chem. 85 (1981) 2049.
M. Audier, J.M. Thomas, J. Klinowski, D.A. Jefferson and L.A. Bursill, J. Phys. Chem. 86 (1982) 581.
G.W. Qiao, J. Lu, J. Zhou and K.H. Kuo, J. Catal. 103 (1987) 170.
O. Terasaki, J.M. Thomas and G.R. Millward, Proc. R. Soc. Lond. A395 (1984) 153.
G.R. Millward, S. Ramdas and J.M. Thomas, Proc. R. Soc. Lond. A399 (1985) 57.
M.M.J. Treacy and J.M. Newsam, Ultramicroscopy 23 (1987) 411.
R. Csencsits and R. Gronsky, Ultramicroscopy 23 (1987) 421.
L.A. Bursill, J.M. Thomas and K.J. Rao, Nature (London) 289 (1981) 157.
E.H. Hirsch, Nature (London) 293 (1981) 759.
L. Petrakis, M.A. Springuel-Huet, T. Ito, T.R. Hughes, I.Y. Chan and J. Fraissard, in:Proc. 9th Intern. Congress on Catalysis, Calgary (1988) Vol. 2, p.348.
K. Heinemann and F. Soria, Ultramicroscopy 20 (1986) 1.
M. Pan, J.M. Cowley and I.Y. Chan, J. Appl. Cryst. 20 (1987) 300.
M. Pan, J.M. Cowley and R. Garcia, Micro & Microscopia Acta 18, No. 3 (1987) 165.
M. Pan, J.M. Cowley and I.Y. Chan, Ultramicroscopy, in press.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pan, M., Cowley, J.M. & Chan, I.Y. HREM imaging of small Pt clusters dispersed in Y-zeolites. Catal Lett 5, 1–11 (1990). https://doi.org/10.1007/BF00772087
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00772087