Skip to main content
Log in

Volume changes in the lower leg during quiet standing and cycling exercise at different ambient temperatures

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Summary

The purpose of this study was to investigate whether ambient temperature influences both the rate of leg swelling during orthostasis and the oedema-preventing effect of the skeletal muscle pump. Using mercuryin-rubber strain gauges, volume changes were measured in the calf (n = 34) and near the ankle (n = 24) in healthy volunteers aged 19–33 years. Measurements were performed during 12 min of motionless standing in an upright posture and during 17 min of cycle exercise at intensities of 50 W and a pedalling rate of 50 rpm. The experiments were done in an air-conditioned chamber at temperatures of 20, 28 and 36°C and 50% relative humidity. The rate of leg swelling, which occurred while standing, did not differ significantly among the three temperatures. The mean increases in calf volume during 10 min (min 2–12) orthostasis were 1.6 (SEM 0.1)%, 1.9 (SEM 0.2)% and 2.0 (SEM 0.2)% at 20, 28 and 36°C respectively. In the ankle region the mean values were 0.9 (SEM 0.1)%, 1.0 (SEM 0.1)%, and 1.0 (SEM 0.1)% at the three temperatures, respectively. Exercising at low temperatures continuously reduced the volume of the leg, but at 36°C the leg volume did not change significantly either at the calf or near the ankle. The mean volume changes measured beteeen min 2 and min 15 were, at the calf, −1.1 (SEM 0.1)%, −0.8 (SEM 0.2)%, and −0.02 (SEM 0.1)% at 20, 28 and 36°C, respectively. Near the ankle the mean changes were −0.7 (SEM 0.1)%, −0.3 (SEM 0.1)%, and +0.2 (SEM 0.1)%. A mathematical description of the time course of the changes supported the view that the changes in the leg volume, which occurred after a subject had been tilted from a supine to an upright posture, consisted of two distinct components. First, the capacitance vessels filled in an exponential manner and second, the leg volume increased linearly, due to augmented transcapillary filtration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aukland K, Nicolaysen G (1981) Interstitial fluid volume: local regulatory mechanisms. Physiol Rev 61:556–643

    Google Scholar 

  • Detry J-MR, Brengelmann GL, Rowell LB, Wyss C (1972) Skin and muscle components of forearm blood flow in directly heated resting man. J Appl Physiol 32:506–511

    Google Scholar 

  • Gauer OH, Thron HL (1965) Postural changes in the circulation. In: Hamilton WS (ed) Handbook of physiology, section 2. Circulation, vol. III. American Physiological Society, Washington, DC, p 2430

    Google Scholar 

  • Gutmann J, Krötz J (1972) Zur Genauigkeit der Dehnungsmeßstreifenmethode bei der venösen Kapazitätsmessung. Folia Angiol 10:103–107

    Google Scholar 

  • Henriksen O, Sejrsen P, Paaske WP, Eickhoff JH (1983) Effect of chronic sympathic denervation upon the transcapillary filtration rate induced by venous stasis. Acta Physiol Scand 117:171–176

    Google Scholar 

  • Henry JP, Gauer OH (1950) The influence on temperature upon venous pressure in the foot. J Clin Invest 29:855–861

    Google Scholar 

  • Krogh A, Landis EM, Turner AH (1932) The movement of fluid through the human capillary wall in relation to venous pressure and to the colloid osmotic pressure of the blood. J Clin Invest 11:63–95

    Google Scholar 

  • Levick JR (1991) An introduction to cardiovascular physiology. Butterworth, London

    Google Scholar 

  • Levick JR, Michel CC (1978) The effects of position and skin temperature on the capillary pressures in the fingers and toes. J Physiol 274:97–109

    Google Scholar 

  • Mellander S, Øberg B, Odelram H (1964) Vascular adjustments to increased transmural pressure in cat and man with special reference to shifts in capillary fluid transfer. Acta Physiol Scand 61:34–48

    Google Scholar 

  • Noddeland H, Aukland K, Nicolaysen G (1981) Plasma colloid osmotic pressure in venous blood from the human foot in orthostasis. Acta Physiol Scand 113:447–454

    Google Scholar 

  • Olszewski W, Engeset A, Jaeger PM, Sokolowski J, Theodorsen L (1977) Flow and composition of leg lymph in normal men during venous stasis, muscular activity and local hyperthermia. Acta Physiol Scand 99:149–155

    Google Scholar 

  • Pollack AA, Wood EH (1949) Venous pressure in the saphenous vein at the ankle in man during exercise and changes in posture. J Appl Physiol 1:649–662

    Google Scholar 

  • Rowell LB (1986) Human circulation. Regulation during physical stress. Oxford University Press, New York

    Google Scholar 

  • Sachs L (1984) Applied statistics. A handbook of techniques. Springer, Berlin Heidelberg New York

    Google Scholar 

  • Schnizer W, Klatt J, Baeker H, Rieckert H (1978) Vergleich von szintigraphischen und plethysmographischen Messungen zur Bestimmung des kapillären Filtrationskoeffizienten in der menschlichen Extremität. Basic Res Cardiol 73:77–84

    Google Scholar 

  • Sejersted OM, Hargens AR, Kardel KR, Blom P, Jensen Oy, Hermansen L (1984) Intramuscular fluid pressure during isometric concentration of human skeletal muscle. J Appl Physiol 56:287–295

    Google Scholar 

  • Sejrsen P, Henriksen O, Paaske WP (1981a) Effect of orthostatic blood pressure changes upon capillary filtration-absorption rate in the human calf. Acta Physiol Scand 111:287–291

    Google Scholar 

  • Sejrsen P, Henriksen O, Paaske WP, Nilesen SL (1981b) Duration of increase in vascular volume during venous stasis. Acta Physiol Scand 111:293–298

    Google Scholar 

  • Stick C, Grau H, Witzleb E (1989) On the edema-preventing effect of the calf muscle pump. Eur J Appl Physiol 59:39–47

    Google Scholar 

  • Stick C, Hiedl U, Witzleb E (1993) Venous pressure in the saphenous vein near the ankle during changes in posture and exercise at different ambient temperatures. Eur J Appl Physiol 66:434–438

    Google Scholar 

  • Stick C, Jaeger H, Witzleb E (1992) Measurements of volume changes and venous pressure in the human lower leg during walking and running. J Appl Physiol 72:2063–2068

    Google Scholar 

  • Taylor AE, Townsley M (1987) Evaluation of the Starling fluid flux equation. NIPS 2:48–52

    Google Scholar 

  • Waterfield RL (1931) The effect of posture on the volume of the leg. J Physiol (Lond) 72:121–131

    Google Scholar 

  • Wenger BC, Roberts MF, Stolwijk JAJ, Nadel ER (1975) Forearm blood flow during body temperature transients produced by leg exercise. J Appl Physiol 38:58–63

    Google Scholar 

  • Whitney RJ (1953) The measurement of volume changes in human limbs. J Physiol 121:1–27

    Google Scholar 

  • Winkel J, Jørgensen K, Noddeland H (1988) Significance of ambient temperature for foot swelling and oedema-preventing effect of modest leg activity while seated. In: Adams AS, Hall RR, McPhee BJ, Oxenburgh MS (ed) Ergonomics International 88. Taylor and Francis, London, pp 140–142

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stick, C., Hiedl, U. & Witzleb, E. Volume changes in the lower leg during quiet standing and cycling exercise at different ambient temperatures. Europ. J. Appl. Physiol. 66, 427–433 (1993). https://doi.org/10.1007/BF00599616

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00599616

Key words

Navigation