Skip to main content
Log in

Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments

  • Head And Neck Radiology
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

Axial spiral CT of the temporal bones with a nominal slice thickness of 1 mm and 180° linear interpolation was performed in 13 patients. In 18 temporal bones, the spiral data set was used to reconstruct overlapping axial images with a table increment of 0.1 mm. These images gave additional information in four cases: in two by examining the heavily overlapping axial images themselves, and in two by obtaining supplementary information from secondary image reconstructions. In two cases less information was obtained than by using the conventional incremental images. This study shows that reconstructing overlapping slices can be useful, even if the temporal bone is scanned at 1 mm nominal slice thickness.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zonneveld FW (1983) The value of non-reconstructive multiplanar CT for the evaluation of the petrous bone. Neuroradiology 25: 1–10

    Google Scholar 

  2. Mafee MF, Kumar A, Tahmoressi CN et al (1988) Direct sagittal CT in the evaluation of temporal bone disease. AJR 9: 371–378

    Google Scholar 

  3. Manzione JV, Rumbaugh CL, Katzberg RW (1985) Direct sagittal computed tomography of the temporal bone. J Comput Assist Tomogr 9: 417–419

    Google Scholar 

  4. Chakeres DW (1984) Clinical significance of partial volume averaging of the temporal bone. AJNR 5: 297–302

    Google Scholar 

  5. Kalender WA, Seissler W, Klotz E, Vock P (1990) Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176: 181–183

    Google Scholar 

  6. Rigauts H, Marchal G, Baert AL, Hupke R (1990) Initial experience with volume CT scanning. J Comput Assist Tomogr 14: 675–682

    Google Scholar 

  7. Kalender WA, Polacin A (1993) Image calculation at submillimetre table increments. Addendum to WIP SPIRAL-2 Operating Instructions. Siemens, Erlangen

    Google Scholar 

  8. Placin A, Kalender WA, Marchal G (1992) Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 185: 29–35

    Google Scholar 

  9. Kalender WA, Polacin A (1991) Physical performance characteristics of spiral CT scanning. Med Phys 18: 910–915

    Google Scholar 

  10. Turski P, Norman D, DeGroot J, Carpa R (1982) High-resolution CT of the petrous bone: direct vs. reformatted images. AJNR 3: 391–394

    Google Scholar 

  11. Kalender WA, Polacin A, Süss C (1994) A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions. J Comput Assist Tomogr 18: 167–176

    Google Scholar 

  12. Veillon F (1991) Imagerie de l'oreille. Flammarion, Paris, p 435

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hermans, R., Marchal, G., Feenstra, L. et al. Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments. Neuroradiology 37, 150–154 (1995). https://doi.org/10.1007/BF00588634

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00588634

Key words

Navigation