Skip to main content
Log in

Cell puncturing with a step motor driven manipulator with simultaneous measurement of displacement

  • Excitable Tissues and Central Nervous Physiology
  • Instruments and Techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Summary

A small angle stepping motor was used for construction of a micropositioner.

Linear movements are produced by direct coupling of the rotor axis to a high precision microdrive. The linearly moving system is constructed from stainless steal prismatic guides with hardened surfaces and permits precise steps in the 100 nm range.

Extreme reduction of the moving masses and minimal friction of the radial thrust bearing enables strong acceleration of the electrode. During simultaneous measurements of step performance motoneurons in the frog spinal cord, CA1 cells of hippocampal brain slices and glia cells in tissue culture were punctured with single electrodes (tip<1 μm) and double barrelled ion-sensitive microelectrodes (Ø 1,5–2 μm). In all three preparations, cell penetration could be performed by means of both types of electrodes with a high yield when the step velocity reached or exceeded 4 mm/s. Steps with lower velocity resulted in less successful cell penetrations and were accompanied by typical dimpling effects. The results indicate that a critical velocity is required for cell puncturing with a minimum of damage.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Benninger C, Kadis J, Prince DA (1980) Extracellular calcium and potassium changes in hippocampal slices. Brain Res 187:165–182

    Google Scholar 

  • Brown KT, Flaming DG (1977) New microelectrode techniques for intracellular work in small cells. Neuroscience 2:813–827

    Google Scholar 

  • Bührle Ch-Ph, Sonnhof U (1981) Intracellular activities of K+, Na+, Ca2+ and Cl in motoneurons and glia cells of the frog spinal cord. Pflügers Arch 389:R94

    Google Scholar 

  • Bührle Ch-Ph, Sonnhof U (1980) Ion fluxes across the membrane of motoneurons during the action of glutamate demonstrated by measurements of intra and extracellular ion activities (aNa e/+i , aCa e/2+i , aK e/+i , aCl e/−i ). In: Proceedings of the Satellite Symposium on ion-selective microelectrodes and their use in excitable tissues of the XVIII. Int. Congress of Physiol. Sciences, Prague, Plenum Press, New York, 1981

    Google Scholar 

  • Ellis GW (1962) Piezoelectric micromanipulators Science 138:84–91

    Google Scholar 

  • Fish RM, Bryan JS, McReynolds JS, Ries JJ (1971): A mechanical microelectrode pulsing device to facilitate the penetration of small cells. IEEE Trans Bio Med Eng 18:240–241

    Google Scholar 

  • Fromm M, Weskamp P, Hegel U (1980) Versatile piezoelectric driver for cell puncture. Pflügers Arch 384:69–73

    Google Scholar 

  • Lassen UV, Rasmussen BE (1978) Use of microelectrodes for measurements of membrane potentials. In: Giebisch G, Tosteson DC, Ussing HH (eds) Membrane transport in biology, Ch 5 of Vol 1 Springer, Berlin, Heidelberg, New York, p 913

    Google Scholar 

  • Peters M, Tetzel HD (1979) A high-speed piezoelectric microelectrode advancer. Pflügers Arch 379:R59

    Google Scholar 

  • Prazma J (1978) Penetration of cells membrane by the piezoelectric driver. Experientia 34:1387

    Google Scholar 

  • Ransom BR, Neale E, Henkart M, Bullock PN, Nelson PG (1977) Mouse spinal cord in cell culture. I. Morphology and intrinsic neuronal electrophysiologic properties. J Neurophysiol 40:1132–1150

    Google Scholar 

  • Sonnhof U, Bührle Ch-Ph (1980) An analysis of glutamate induced ion fluxes across the membrane of spinal motoneurones of the frog. Adv Biochem Psychopharmacol 27:195–204

    Google Scholar 

  • Sonnhof U, Grafe P, Krumnikl J, Linder M, Schindler L (1975) Inhibitory postsynaptic actions of taurine, GABA and other amino acids on motoneurons of the isolated frog spinal cord. Brain Res 100:327–341

    Google Scholar 

  • Tupper JT, Rikmenspoel R (1969) Piezoelectric device for glass microelectrodes. Rev Sci Instrum 10:851–852

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sonnhof, U., Förderer, R., Schneider, W. et al. Cell puncturing with a step motor driven manipulator with simultaneous measurement of displacement. Pflugers Arch. 392, 295–300 (1982). https://doi.org/10.1007/BF00584314

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00584314

Key words

Navigation