Skip to main content
Log in

Surface analysis for Si-wafers using total reflection X-ray fluorescence analysis

Oberflächenanalyse für Si-Wafer mit Hilfe streifend einfallender Röntgenstrahlen

  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

Total Reflection X-Ray Fluorescence Analysis is presented as a novel analytical tool for the determination of metal impurities on Si-Wafer surfaces [1]. This method allows accurate quantification of surface coverages down to 1011 atoms/cm2 in a non-destructive way. The technique uses a molybdenum tube, a Si(Li) detector, and instrumentation for the exact control of the angle of incidence which must be set to a particular value below the cricitical angle for total reflection with an accuracy better than 0.1 mrad. Advantages are the lack of sample preparation and vacuum. Standards for quantification can be easily produced. Repeatability tests on three different wafers show good variability even for low concentrations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Eichinger P, Rath H, Schwenke H (1988) Application of total reflection X-ray fluorescence analysis for metallic trace impurities on silicon wafer surfaces. In: Gupta C (ed) Semiconductor fabrication: technology and metrology, ASTM STP 990. American Society for Testing and Materials

  2. Knoth J, Schwenke H (1978) Fresenius Z Anal Chem 291:200

    Google Scholar 

  3. Analytical Chemistry Division, International Union of Pure and Applied Chemistry (1978) Spectrochim Acta 33:241

    Google Scholar 

  4. Schwenke H, Knoth J, Weisbrod U, Neumann C (1988) Determination of metallic impurities in the surface of silicon wafers by total reflection X-ray flurorescence analysis. Pittsburgh Conference, Book of Abstracts, Extended Abstract No. 1236

  5. Penka V, Hub W, submitted to Spectrochim Acta

  6. Eichinger P (1988) New analytical tools for the assessment of metallic trace contamination in silicon wafer technology. Presented at Semicon/Europa Techn. Conference, Zürich, Switzerland

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Berneike, W., Knoth, J., Schwenke, H. et al. Surface analysis for Si-wafers using total reflection X-ray fluorescence analysis. Z. Anal. Chem. 333, 524–526 (1989). https://doi.org/10.1007/BF00572369

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00572369

Keywords

Navigation