Summary
A new enzyme-linked immunosorbent assay (ELISA) screening test for total rheumatoid factor (RF) activity is described. Rabbit IgG was used as antigen and enzyme-conjugated monoclonal anti-kappa antibody as third layer. Of 183 samples measured for RF isotype levels, 60 were found to have one or more raised. In terms of raised isotypes the ELISA screening test had a sensitivity of 97% (58/60) while the Rheumaton had a sensitivity of only 75% (45/60). Nearly all discordant false-negative samples had only one RF isotype raised. The ELISA test gave 29% (53/183) and the Rheumaton 34% (63/183) false-positive results. Thus the ELISA test was more specific and sensitive for the detection of raised single RF isotypes than the Rheumaton and Rose-Waaler tests. Moreover, approximately 30% of RA patients were seronegative according to the conventional RF tests but only 8% in the new ELISA system.
Similar content being viewed by others
References
Teitsson I, Withrington RH, Seifert MH, Valdimarrson H (1984) Prospective study of early rheumatoid arthritis. I. Prognostic value of IgA rheumatoid factor. Ann Rheum Dis 43:673–678
Hay FC, Nineham LJ, Roitt IM (1975) Routine assay for detection of IgG and IgM antiglobulins in seronegative and seropositive rheumatoid arthritis. Br Med J [Clin Res] 3:203–204
Nineham LJ, Hay FC, Roitt IM (1976) Laboratory diagnosis of rheumatoid arthritis: a solid phase radioassay for IgG and IgM antiglobulins. J Clin Pathol 29:1121–1126
Carson DA, Lawrence S, Catalano MA, Vaughan JH, Abraham G (1977) Radioimmunoassay of IgG and IgM rheumatoid factors reacting with human IgG. J Immunol 119:295–300
Koopman WJ, Schrohenloher RE (1980) A sensitive radio-immunoassay for quantitation of IgM rheumatoid factor. Arthritis Rheum 23:302–308
Willems FTC, de Kort CCMK (1978) ELISA for rheumatoid factor. Lancet I:994–995
Halbert SP, Karsh J, Anken M (1980) A quantitative enzyme immunoassay for IgM rheumatoid factor using human immunoglobulin G as substrate. Am J Clin Pathol 74:776–784
Tarkowski A, Bjursten LM, Nilsson L-Å, Nygren H (1983) False positive results in class-specific rheumatoid factor (RF) assays due to interaction between RF and Fc fragments of anti-immunoglobulin indicator reagents. J Immunol Methods 58:171–182
Teitsson I, Valdimarsson H (1984) Use of monoclonal antibodies and F(ab')2 enzyme conjugates in ELISA for IgM, IgA and IgG rheumatoid factors. Immunol Methdos 71:149–161
Bampton JLM, Cawston TE, Kyle MV, Hazleman BL (1985) Measurement of rheumatoid factors by an enzyme-linked immunosorbent assay (ELISA) and comparison with other methods. Ann Rheum Dis 44:13–19
Carson DA, Lawrence S (1978) Light chain heterogeneity of 19S and 7S anti-γ-globulins in rheumatoid arthritis and subacute bacterial endocarditis. Arthritis Rheum 21:438–440
Roberts-Thomson PJ, Wernick RM, Ziff M (1982) Quantitation of rheumatoid factor by laser nephelometry. Rheumatol Int 2:17–20
Maiolini R, Ferrua B, Quaranta JF, Pinoteau A, Euller L, Ziegler G, Masseyeff R (1978) A sandwhich method of enzyme-immunoassay. II. Quantification of rheumatoid factor. J Immunol Methods 20:25–34
Hällgren R, Wide L (1977) Precipitation of 125I-labelled IgG aggregates by factors in sera of healthy individuals and of patients with rheumatoid arthritis. Ann Rheum Dis 36:21–29
Yamagata J, Barnett EV, Knutson DW, Nasu H, Chia D (1979) Characterisation and measurement of anti-IgG antibodies in human sera by radioimmunossay (RIA). J Immunol Methods 29:43–56
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jonsson, T., Arnason, J.A. & Valdimarsson, H. Enzyme-linked immunosorbent assay (ELISA) screening test for detection of rheumatoid factor. Rheumatol Int 6, 199–204 (1986). https://doi.org/10.1007/BF00541367
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00541367