Skip to main content
Log in

Kaliumselektive Membranelektroden auf der Basis des Kryptanden [2B2B2]

Potassium-selective membrane electrodes based on the cryptand [2B2B2]

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

According to the principle of dilution, the cryptand [2B2B2] was synthesized by several cyclisations. For the installation in a commercially available electrode, the cryptand was used as the basic substance for three kinds of membranes: one liquid-membrane on diphenylether and two solid-membranes, one on polystyrene and the other on polyvinyl chloride. Except for the polystyrene type, the prepared sensors produced linear potentials for pure solutions of potassium over a concentration range of about 10−6 to 10−1 mol/l. The liquid-electrode and the PVC-electrode were both selective for potassium, the latter one achieving better results. Unfortunately they had not very long life periods, particuarly under extreme conditions. Therefore, occasionally, their desactivated membranes had to be replaced frequently.

Zusammenfassung

Der Kryptand [2B2B2] wurde durch mehrere Cyclisierungsreaktionen unter Berücksichtigung des Verdünnungsprinzips synthetisiert. Damit wurden drei verschiedene, auf Kalium ansprechende Membranen für den Einbau in einen im Handel erhältlichen Elektrodenkörper hergestellt: eine Diphenylether-Flüssigmembrane und je eine Polystyrol- bzw. PVC-Festkörpermembrane. Die meßfertigen Sensoren ergaben mit Ausnahme der Polystyrolmembrane über mehrere Aktivitätsdekaden linear ansteigende Potentiale für reine Kaliumsalzlösungen von ca. 5×10−6 bis 10−1 [mol/l]. Die Sensoren erwiesen sich, wiederum mit Ausnahme der Polystyrolmembranelektrode, als selektiv für Kalium; dabei lieferte der PVC-Sensor etwas günstigere Ergebnisse. Nachteilig wirkte sich aus, daß die Elektroden auf Grund der verhältnismäßig kurzen Lebensdauer der Membranen in ihrer Benutzbarkeit eingeschränkt waren und die jeweils potentialbestimmende Phase des öfteren regeneriert werden mußte.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Blasius, E., Maurer, P.-G.: Makromol. Chem. 178, 649 (1977)

    Google Scholar 

  2. Brown, H. C., Zweifel, G.: Org. Reactions 13, 1 (1963)

    Google Scholar 

  3. Dietrich, B., Lehn, J. M., Sauvage, J.-P.: Chem. in unserer Zeit 7, 120 (1973)

    Google Scholar 

  4. Dietrich, B., Lehn, J. M., Sauvage, J.-P., Blanzat, J.: Tetrahedron 29, 1629 (1973)

    Google Scholar 

  5. Schindler, J. G., Riemann, W.: Biomed. Techn. 20, 75 (1975)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Wir danken der Deutschen Forschungsgemeinschaft, Bonn-Bad Godesberg, dem Minister für Wissenschaft und Forschung des Landes Nordrhein-Westfalen, Landesamt für Forschung sowie dem Verband der Chemischen Industrie, Fonds der Chemie, für Sachbeihilfen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gajowski, J., Rieckemann, B. & Umland, F. Kaliumselektive Membranelektroden auf der Basis des Kryptanden [2B2B2]. Z. Anal. Chem. 309, 343–346 (1981). https://doi.org/10.1007/BF00473712

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00473712

Key words

Navigation