Summary
We have developed a method of segmental spinal instrumentation that precludes the passage of sublaminar wires, thus reducing the likelihood of neurological complications. The technique utilizes the base of the spinous process as the purchase site for segmental fixation and a newly developed buttonwire implant. The technique and early experience with this method are described.
Zusammenfassung
Wir haben eine Methode der instrumentellen segmentalen Wirbelsäulenstabilisie-rung entwickelt, die die Verwendung wirbelbogenumgreifender Drähte vermeidet and dadurch die Wahrscheinlichkeit neurologischer Komplikationen herabsetzt. Diese Technik vermendet einen neuentwickelten Knopfdraht and wählt als Ort der Fixation die Basis des Dornfortsatzes. Die Technik dieser Methode and erste Erfahrungen werden mitgeteilt.
Similar content being viewed by others
References
Allen BL, Ferguson RL (1982) The Galveston technique for L-rod instrumentation of the scoliotic spine. Spine 7:276–284
Bryant LE, Sullivan JA (1983) Management of thoracic and lumbar spine fractures with Harrington rods supplemented with segmental wiring. Spine 8:532–537
Drummond DS, Guadagni J, Keene JS, Breed A, Narechania RG (1984) Interspinous process segmental spinal instrumental. J Pediatr Orthop (in press)
Herring JA, Wenger DR (1982) Segmental spinal instrumentation: a preliminary report of 40 consecutive cases. Spine 7:285–298
Jones SJ, Edgar MA, Ransford AO, Thomas NP (1982) A system for the electrophysiological monitoring of the spinal cord during operations of scoliosis. J Bone Joint Surg [Br] 65:134–139
Keene JL, Drummond DS, Narechania RG (1982) The Wisconsin compression system. Spine 7:83–85
Luque ER (1977) Treatment of scoliosis without arthrodesis or external support. Orthop Trans 1:37
Luque ER (1982) The anatomic basis and development of segmental spinal instrumentation. Spine 7:256–259
Narrnzadeh N, Lane M, Graham J, Neurith M, Bernstein R (1983) Somatosensory evoked potentials: intraoperative indicators of spinal cord function. A clinical analysis of 157 surgical spinal procedures. Read at the 18th Annual Meeting of the Scoliosis Research Society, New Orleans, October 1983
Perry JO, Nickel VL, Bonnett C (1968) Halo-button-traction wire technique of spine fusion in the non-ambulatory respiratory patient with spine instability. J Bone Joint Surg [Am] 50:1059–1060
Resina J, Ferreira-Alves A (1977) A technique of correction and internal fixation for scoliosis. J Bone Joint Surg [Br] 59:159–165
Wenger DR, Carollo JJ, Wikerson JA, Wanthers K, Herring JA (1982) The laboratory testing of segmental spinal instrumentation versus traditional Harrington instrumentation for scoliosis treatment. Spine 7:265–269
Wilber GL, Thompson GH, Shaffer JW, Brown RH (1983) Spinal cord monitoring and neurologic deficits in segmental spinal instrumentation. Read at the 18th Annual Meeting of the Scoliosis Research Society, New Orleans, October 1983
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Drummond, D.S., Keene, J. & Breed, A. Segmental spinal instrumentation without sublaminar wires. Arch. Orth. Traum. Surg. 103, 378–384 (1985). https://doi.org/10.1007/BF00435445
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00435445