Abstract

For the separation of trace elements from water cellulose containing chromotropic acid as functional group is used in form of thin filters (capacity 0.0075 mEq.). The time necessary for the filtration of 100 ml is about 10 min. The behaviour of the elements Fe, Cu, Zn, Sr and Hg is studied in detail. Fe, Cu, Zn and Sr are fixed on the filter in the range from pH 4–6.5 with a yield >90%, provided the content of the elements does not exceed the capacity of the filter. Larger amounts of calcium ions or sodium ions interfere considerably with the separation of the elements mentioned above. The filters are used directly for analysis by X-ray fluorescence. Calibration curves for the elements with atomic number 25–38 are presented. For comparison Chelex filters are investigated, too. The advantages and disadvantages in the use of the cellulose filters are discussed.

Zusammenfassung

Für die Abtrennung von Spurenelementen aus Wasser wird ein Celluloseaustauscher mit Chromotropsäure als funktioneller Gruppe in Form von dünnen Filtern verwendet (Kapazität etwa 0,0075 mÄq.). Die Filtrationszeit für 100 ml Wasser beträgt etwa 10 min. Das Verhalten der Elemente Fe, Cu, Zn, Sr und Hg wird näher untersucht. Fe, Cu, Zn und Sr werden im pH-Bereich von etwa 4–6,5 mit einer Filtrationsausbeute >90 % festgehalten, sofern der Gehalt die Kapazität des Filters nicht übersteigt. Größere Gehalte an Calcium-Ionen oder Natrium-Ionen stören die Abtrennung erheblich. Die Filter werden direkt für die Röntgenfluorescenzanalyse verwendet. Eichkurven für die Elemente mit den Ordnungszahlen 25–38 werden angegeben. Zum Vergleich werden Chelex-Filter herangezogen. Die Vor- und Nachteile der Verwendung von Celluloseaustauscher-Filtern werden diskutiert.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Blount, C. W., Leyden, D. E., Thomas, L., Guill, S. M.: Anal. Chem. 45, 1045–1050 (1973)

    Google Scholar 

  2. Burba, P., Lieser, K. H.: Angew. Makromol. Chem. 50, 151 (1976)

    Google Scholar 

  3. Burba, P., Lieser, K. H.: Fresenius Z. Anal. Chem. 279, 17 (1976)

    Google Scholar 

  4. Campbell, W. J., Spano, E. F., Green, T. E.: Anal. Chem. 38, No. 8, 987–996 (1966)

    Google Scholar 

  5. Cothern, C. R.: Determination of Trace Metals Pollutants in Water Resources Using X-ray Fluorescence. Annual Report, Univ. Dayton, Ohio 1970/71

    Google Scholar 

  6. Elder, J. F., Perry, S. K., Brady, F. P., Goldman, C. R.: Trace metal analysis of natural water samples by dithiocarbamate precipitation coupled with X-ray fluorescence. Crocker Nuclear Lab., Univ. of California, 1973

  7. Haberer, K.: Jahrb. Wasser 32, 128 (1965)

    Google Scholar 

  8. Hellmann, H., Griffatong, A.: Fresenius Z. Anal. Chem. 257, 343–345 (1971)

    Google Scholar 

  9. Holyńska, B., Leszko, M., Nahlik, E.: J. Radioanal. Chem. 13, 401–411 (1973)

    Google Scholar 

  10. Kölle, W., Park, Y. K., Sontheimer, A.: Jahrb. Wasser 34, 31–39 (1967)

    Google Scholar 

  11. Leyden, D. E., Luttrell, G. H.: Immobilization of chelating groups using silylation reactions. Univ. Georgia 1974

  12. Luke, C. L.: Anal. Chem. 36, 318 (1964)

    Google Scholar 

  13. Vanderborght, B. M., van Grieken, R. E.: Energy dispersive X-ray fluorescence for trace metal analysis of water, Antwerp Univ., Belgium, 1974

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lieser, K.H., Röber, HM. & Burba, P. Abtrennung von Spurenelementen aus Wasser mit Hilfe von Celluloseaustauscher-Filtern und ihre Bestimmung durch Röntgenfluorescenzanalyse mit Radionuklidanregung. Z. Anal. Chem. 284, 361–368 (1977). https://doi.org/10.1007/BF00428141

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00428141

Navigation