Improved “active” electrodes for recording bioelectric signals in work physiology

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Summary

Conventional recording techniques of bioelectric signals using surface electrodes are often very sensitive to artefacts, in particular when carrying out physiological investigations in ergonomics and sports.

An “active” electrode, by means of impedance-converting-amplification, was developed to signals. The application of these electrodes on the skin surface does not differ from that of conventional electrodes. The circuit elements of the impedance-converting-preamplifier, including a power-supply, are placed in a small portable housing. A qualitative comparison between conventional Ag/AgCl electrodes and “active” electrodes in ECG and EMG recordings with artefact simulation shows a high degree of artefact suppression for the “active” electrodes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Basmajian JV (1979) Muscles alive. The Williams & Wilkins Company, Baltimore

    Google Scholar 

  • Finley FR, Wirta RW, Cody KA (1968) Muscle synergies in motor performance. Arch Phys Med Rehab 49: 655–660

    Google Scholar 

  • Rau G (1973a) Der Einflu\ der Elektroden- und Hautimpedanz bei Messungen mit OberflÄchenelektroden (EMG). Biomed Technik 18: 23–27

    Google Scholar 

  • Rau G (1973b) Ein verbessertes Me\system zur quantitativen OberflÄchenmyographie, Anthropotechnische Mitteilung Nr. 2, Forschungsinstitut für Anthropotechnik, Meckenheim

    Google Scholar 

  • Theysohn H, Schumacher J (1984) Verbesserung der Artefaktunterdrückung beim OberflÄchenmyogramm durch aktive Hochpa\filter mit variabler Grenzfrequenz bei möglichst kleinem Nutzsignalverlust. Biomed Technik 29: 175–180

    Google Scholar 

  • Tietze U, Schenk CH (1983) Halbleiter-Schaltungstechnik. Springer, Berlin Heidelberg New York Tokyo

    Google Scholar 

  • Zipp P (1978) Die Bemessung der Elektroden-Haut-KontaktflÄche und der VerstÄrkereingangsimpedanz bei der quantitativen OberflÄchenelektrographie (EKG) und (EMG). Biomed Technik 23: 130–140

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hagemann, B., Luhede, G. & Luczak, H. Improved “active” electrodes for recording bioelectric signals in work physiology. Europ. J. Appl. Physiol. 54, 95–98 (1985). https://doi.org/10.1007/BF00426306

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00426306

Key words

Navigation