Ergebnisse zur Zerstäubung dosierter Lösungsvolumina bei der AAS

Results of the atomizing method using measured volumes of liquid samples by A.A.S

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Abstract

The decrease of the insert volume of high concentrated sample solutions extends the function time of laminar burners. But those small sample quantities pass the absorption zone within a period of time which is below the constant rise time of the indicating system. That means that the signals are not only dependent on the concentration, but also on the volume of the sample solution. Therefore it must be kept completely constant. The damping of the instrument must also be adjusted to it. The measurement of small quantities of sample volumes is possible because the decrease of the volume from about 500 μl to about 25 μl has the consequence of increasing the absolute sensitivity to its threefold value.

Zusammenfassung

Die Verringerung des Probenvolumens stark salzhaltiger Analysenlösungen führt bei der AAS zu einer Verlängerung der Funktionsdauer von Laminarbrennern. Die kleinen Probenmengen passieren allerdings die Absorptionszone innerhalb einer Zeitspanne, die oft unterhalb der Anstiegszeitkonstanten des Indikationssystems liegt. Daraus ergibt sich, daß die Signale nicht nur von der Konzentration, sondern auch vom Volumen der Probelösung abhängen, das aus diesem Grunde genau konstant gehalten werden muß. Die Gerätedämpfung sollte ebenfalls abgestimmt werden. Messungen bei kleinen Volumina werden möglich, weil bei der Verringerung des Probenvolumens von etwa 500 μl auf etwa 25 μl die absolute Nachweisempfindlichkeit auf den etwa dreifachen Wert ansteigt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Arbeitskreis „Automation in der Analyse“: diese Z. 261, 1 (1972).

    Google Scholar 

  2. Hell, A., Ramirez-Muñoz, J.: Anal. Chim. Acta 51, 141 (1970).

    Article  CAS  Google Scholar 

  3. Höhn, R., Umland, F.: diese Z. 258, 100 (1972).

    Google Scholar 

  4. Ramirez-Munoz, J.: Developm. Appl. Spectroscopy 7A, 169 (1969).

    Article  Google Scholar 

  5. Rampon, H.: Chim. Anal. (Paris) 51, 627 (1969).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Vortrag anläßlich der Tagung Euroanalysis I, 28. 8. bis 1. 9. 1972 in Heidelberg.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sebastiani, E., Ohls, K. & Riemer, G. Ergebnisse zur Zerstäubung dosierter Lösungsvolumina bei der AAS. Z. Anal. Chem. 264, 105–109 (1973). https://doi.org/10.1007/BF00424620

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00424620

Navigation