Skip to main content
Log in

Die Messung der Leberdurchblutung mit der Kr-85 Clearance bei Ratten im Entblutungsschock

  • Published:
Pflüger's Archiv für die gesamte Physiologie des Menschen und der Tiere Aims and scope Submit manuscript

Summary

In rats with normal blood pressure, during stepwise bleeding, and stepwise reinfusion, the activity of Kr-85 on the liver surface was measured after intraportal injection of saline containing the isotope. In rats with normal and diminished blood pressure the activity curves of the liver surface after intraportal injection of Kr-85 showed a decline following an exponential function. According to the evaluation of Ingvar and Lassen (1962) 50 measurements of the regional liver blood flow in 15 rats showed a blood flow with a mean value of 1,4±0,54 ml/g×min and according to Zierler (1965) 0,95±0,32 ml/g×min. Measurements in the same animal were well to reproduce. The relatively low values according to Zierler (1965) possibly arise because the activity of the whole organ was not measured. The pressure-flow relationship runs in nearly linear way as well during bleeding as after reinfusion. Below arterial pressures of about 60 mm Hg or portal pressures of about 5 mm Hg the resistance increases at a high rate. It is to be supposed that under these values the critical pressure for opening the sinusoids is not reached.

Zusammenfassung

An Ratten mit normalem Blutdruck sowie bei stufenweiser Entblutung und stufenweiser Reinfusion wurde die Kr-85 Aktivität der Leberoberfläche nach intraportaler Injektion des in physiologischer Kochsalzlösung gelösten Isotops registriert. Aktivitätskurven in der Leberoberfläche nach intraportaler Injektion von Kr-85 bei normalem und herabgesetztem Blutdruck von Ratten zeigen einen Abfall, der weitgehend einer Exponentialfunktion folgt. 50 Messungen der regionalen Leberdurchblutung von 15 Versuchstieren mit normalem Blutdruck ergaben bei der Auswertung nach Ingvar u. Lassen (1962) im Mittel eine Durchblutung von 1,4±0,54 ml/g · min und nach Zierler (1965) 0,95±0,32 ml/g · min. Die nach Zierler (1965) erhaltenen, relativ geringen Durchblutungswerte kommen möglicherweise dadurch zustande, daß eine Voraussetzung des Verfahrens, nämlich die Aktivitätsmessung des gesamten Organs, nicht erfüllt ist. Messungen am gleichen Versuchstier waren gut reproduzierbar. Mit abnehmendem arteriellen Blutdruck nehmen der Druck in der Vena portae und die Leberdurchblutung annähernd linear ab. Nach stufenweiser Reinfusion besteht zwischen Leberdurchblutung und Portaldruck bzw. arteriellem Blutdruck nahezu die gleiche Beziehung wie bei Entblutung. Sinkt der arterielle Druck unter 60 mm Hg bzw. der Portaldruck unter ca. 5 mm Hg, so steigt der Strömungswiderstand der Leber steil an, da dann für eine zunehmend größere Anzahl von Sinusoiden der kritische Öffnungsdruck nicht mehr gegeben sein dürfte.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Benacerraf, B., D. Bilbey, G. Biozzi, B. N. Halpern, and C. Stiffel: The measurement of liver blood flow in partially hepatectomized rats. J. Physiol. (Lond.) 136, 287 (1957).

    Google Scholar 

  • Betz, E., D. H. Ingvar, N. A. Lassen, and F. W. Schmahl: Regional blood flow in the cerebral cortex, measured simultaneously by heat and inert gas clearance. Acta physiol. scand. 67, 1 (1966).

    Google Scholar 

  • Brauer, R. W.: Liver circulation and function. Physiol. Rev. 43, 115 (1963).

    Google Scholar 

  • —— Autoregulation of blood flow in the liver. Circulat. Res. 15, Suppl. 1, 213 (1965).

    Google Scholar 

  • ——, and G. F. Leong: Temperature effects on radiocolloid uptake by the isolated rat liver. Amer. J. Physiol. 189, 24 (1957).

    Google Scholar 

  • ——, and R. J. Holloway: Circulatory pathways in the rat liver as revealed by P32 chromic phosphate colloid uptake in the isolated perfused preparation. Amer. J. Physiol. 184, 593 (1956).

    Google Scholar 

  • Dobsen, E. L., and H. B. Jones: The behaviour of intravenously injected particulate material. Acta med. scand. 144, (Suppl.) 273 (1952).

    Google Scholar 

  • Ginsburg, M., and J. Grayson: Factors controlling liver blood flow in the rat. J. Physiol. (Lond.) 123, 574 (1954).

    Google Scholar 

  • Grayson, J., and D. Mendel: The role of the spleen and the hepatic artery in the regulation of liver blood flow. J. Physiol. (Lond.) 136, 60 (1957).

    Google Scholar 

  • Herd, J. A., M. Hollenberg, G. D. Thorburn, H. H. Kopald, and A. C. Barger: Myocardial blood flow determined with krypton 85 in unanesthetized dogs. Amer. J. Physiol. 203, 122 (1962).

    Google Scholar 

  • Hollenberg, M., and J. Dougherty: Liver blood flow measured by portal venous and hepatic arterial routes with Kr-85. Amer. J. Physiol. 210, 926 (1966).

    Google Scholar 

  • Ingvar, H., and N. A. Lassen: Regional blood flow of the cerebral cortex determined by krypton 85. Acta physiol. scand. 54, 325 (1962).

    Google Scholar 

  • Johnson, D. H.: The effects of haemorrhage and hypertension on the liver blood flow. J. Physiol. (Lond.) 126, 413 (1954).

    Google Scholar 

  • Kety, S. S.: Measurement of regional circulation by the local clearance of radioactive sodium. Amer. Heart J. 38, 321 (1949).

    Google Scholar 

  • Ladefoged, J., F. Pedersen, U. Doutheil, P. Deetjen, and E. E. Selkurt: Renal blood flow measured with Xenon-133 wash-out technique and with an electromagnetic flowmeter. Pflügers Arch. ges. Physiol. 284, 195 (1965).

    Google Scholar 

  • Lassen, N. A., and H. Ingvar: The blood flow of the cerebral cortex determined by radioactive krypton-85. Experientia (Basel) 17, 42 (1961).

    Google Scholar 

  • Meier, P., and K. L. Zierler: On the theory of the indicator-dilution method for measurement of blood flow and volume. J. appl. Physiol. 6, 731 (1954).

    Google Scholar 

  • Selkurt, E. E.: Validity of the bromsulphthalein (BSP) method for estimating hepatic blood flow. Amer. J. Physiol. 175, 461 (1953).

    Google Scholar 

  • —— In Bradley, S. E.: Hepatic blood flow in experimental shock. Shock and Circulatory Homeostasis.

  • Seneviratne, R. D.: Physiological and pathological responses in the bloodvessels of the liver. Quart. J. exp. Physiol. 35, 77 (1949).

    Google Scholar 

  • Zierler, K. E.: Equations for measuring blood flow by external monitoring of radioisotopes. Circulat. Res. 16, 309 (1965).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Waldeck, F., Hutten, H. & Grote, J. Die Messung der Leberdurchblutung mit der Kr-85 Clearance bei Ratten im Entblutungsschock. Pflügers Archiv 294, 201–213 (1967). https://doi.org/10.1007/BF00412986

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00412986

Navigation