Skip to main content
Log in

A direct-reading device for measurement of patch-clamp micropipette tip diameters

  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Abstract

This paper describes an electronic device for the measurement of the diameter of the tip opening of micropipettes. The device measures the threshold pressure required to produce bubbles from the micropipette submerged in a liquid and displays the tip inner diameter in micrometres. We demonstrate that this technique can be used effectively in a range of liquids of different density, surface tension and viscosity and that the thickness of the glass from which the micropipettes are made does not influence the measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

P B :

Threshold bubbling pressure

β :

bubble buoyancy

γ :

surface tension

d :

inner diameter of pipette tip

ϱ :

liquid density

g :

acceleration due to gravity

h :

depth of immersion of micropipette tip

References

  1. Brown KT, Flaming DG (1977) New microelectrode techniques for intracellular work in small cells. Neuroscience 2:813–827

    Google Scholar 

  2. Clift R, Grace JR, Weber ME (1978) Bubbles, drops, and particles. Academic Press, New York, p 321

    Google Scholar 

  3. Corey DP, Stevens GF (1983) Science and technology of patch-recording electrodes. In: Sakmann B, Neher E (eds) Singlechannel recording. Plenum, New York, pp 66–67

    Google Scholar 

  4. Davidson JF, Schüller BOG (1960) Bubble formation at an orifice in an inviscid liquid. Trans Inst Chem Eng 38:335–342

    Google Scholar 

  5. Kupferberg A, Jameson GJ (1969) Bubble formation at a submerged orifice above a gas chamber of finite volume. Trans Inst Chem Eng 47:T241-T250

    Google Scholar 

  6. Landau LD, Lifshitz EM (1959) Fluid mechanics. Pergammon Press, Oxford

    Google Scholar 

  7. Mittman S, Flaming DG, Copenhagen DR, Belgum JH (1987) Bubble pressure measurement of micropipet tip outer diameter. J Neurosci Methods 22:161–166

    Google Scholar 

  8. Purves RD (1981) Microelectrode methods for intracellular recording and iontophoresis. Academic Press, London, p 146

    Google Scholar 

  9. Pusch M, Neher W (1988) Rates of diffusional exchange between small cells and a measuring patch pipette. Pflügers Arch 411:204–211

    Google Scholar 

  10. Ruff K (1972) Bildung von Gasblasen an Düsen bei konstantem Volumendurchsatz. Chem Ing Technol 44:1360–1366

    Google Scholar 

  11. Weast RC, Astle MJ, Beyer WH (1988) CRC Handbook of physics and chemistry, 69th edn. CRC Press, Boca Raton

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Martin, D.K., Cook, D.I. A direct-reading device for measurement of patch-clamp micropipette tip diameters. Pflugers Arch. 417, 255–258 (1990). https://doi.org/10.1007/BF00370989

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00370989

Key words

Navigation