Summary
The time course of the Bohr effect on thin blood lamellas, consisting of a single layer of erythrocytes with a plasma layer on both sides, is examined. The O2 saturation change of the hemoglobin, following a sudden change in the CO2 pressure, is carried out in both directions at a temperature of 37° C, within the range \(S_{{\text{O}}_{\text{2}} } = 83\% \) and 49%, and photometrically analyzed.
The analysis shows that:
-
1.
The time needed for the increase in the O2 saturation of the blood lamellas is approximately 6 times greater than that required by the O2 desaturation process. The average half-value times are 0.97 sec and 0.17 sec, respectively.
-
2.
The O2 desaturation process, following a CO2 pressure increase, needs almost as much time as a desaturation process in the same range, after an O2 pressure decrease. Hence, it follows that the O2 diffusion rate can temporally limit the CO2 exchange in this direction.
-
3.
After a CO2 decrease, the time course of the longer O2 saturation process depends on the quantity of HCO −3 inside the erythrocyte. When there is a considerable CO2 jump, the Hamburger shift can temporally limit the Bohr effect.
Zusammenfassung
Es wird der zeitliche Ablauf des Bohr-Effektes an dünnen Blutlamellen, bestehend aus einer einlagigen Erythrocytenschicht mit beidseitigem Plasmarand, untersucht. Die einer plötzlichen Änderung des CO2-Druckes folgende O2-Sättigungsänderung des Hämoglobins wird bei 37° C im Bereich zwischen \(S_{{\text{O}}_{\text{2}} } = 83\% \) und 49% in beiden Richtungen durchgeführt und photometrisch analysiert.
Dabei ergibt sich:
-
1.
Die Zeit für den Anstieg der O2-Sättigung der Blutlamelle ist etwa sechsmal länger als die für die O2-Entsättigung. Die mittleren Halbwertzeiten betragen 0,97 bzw. 0,17 sec.
-
2.
Der O2-Entsättigungsvorgang nach einer CO2-Druckerhöhung benötigt fast die gleiche Zeit wie die im selben Bereich ablaufende Entsättigung nach einer O2-Druckerniedrigung. Daraus folgt, daß die O2-Diffusionsrate den CO2-Austausch in dieser Richtung zeitlich begrenzen kann.
-
3.
Der längere O2-Aufsättigungsprozeß nach einer CO2-Druckerniedrigung hängt in seinem zeitlichen Ablauf von der Menge des ausgetauschten HCO −3 ab. Bei größeren CO2-Sprüngen kann die Hamburger-Shift den Bohr-Effekt zeitlich begrenzen.
Similar content being viewed by others
Literatur
Constantine, H. P., M. R. Craw, and R. E. Forster: Rate of the reaction of carbon dioxide with human red blood cells. Amer. J. Physiol. 208, 801 (1965).
Craw, M., H. P. Constantine, J. A. Morello, and R. E. Forster: Rate of the Bohr shift in human red cell suspensions. J. appl. Physiol. 18, 317 (1963).
Forster, R. E.: The rapidity of exchanges between red cells and plasma. In: Physical bases of circulatory transport: regulation and exchange, edited by E. B. Reeve and A. C. Cuyton, chapt 21, p. 343. Philadelphia-London: W. B. Saunders Comp. 1967.
Nakamura, T., and N. C. Staub: Synergism in the kinetic reactions of O2 and CO2 with human red blood cells. J. Physiol. (Lond.) 173, 161 (1964).
Piiper, J.: Geschwindigkeit des CO2-Austausches zwischen Erythrocyten und Plasma. Pflügers Arch. ges. Physiol. 278, 500 (1964).
Siesjö, B., u. G. Thews: Ein Verfahren zur Bestimmung der CO2-Leitfähigkeit und des CO2-Diffusionskoeffizienten im Gehirngewebe. Pflügers Arch. ges. Physiol. 276, 192 (1962).
Slyke, D. D. van, J. Sendroy jr., and S. H. Liu: Manometric analysis of gas mixtures. III. Manometric determination of carbon dioxide tension and pH s of blood. J. biol. Chem. 95, 547 (1932).
Wright, J.: Applied Physiology. London-New York-Toronto: Oxford University Press 1952.
Author information
Authors and Affiliations
Additional information
Mit Unterstützung durch die Bergbau-Berufsgenossenschaft.
Rights and permissions
About this article
Cite this article
Schultehinrichs, D., Vogel, H.R. & Thews, G. Modelluntersuchungen zum Austausch der Atemgase. Pflügers Archiv 301, 302–310 (1968). https://doi.org/10.1007/BF00362640
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00362640