The use of coronal tomograms for CT scanning of the orbits is emphasized and the technic for patient positioning is described. Normal tomographic images are described and the contribution of coronal scans to a correct diagnosis is stressed in the light of 16 pathological cases. Coronal tomograms are especially valuable to show the regions of the orbital floor and roof and complement axial scanning.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ambrose, J.A.E., Lloyd, G.A.S., Wright, J.E.: A preliminary evaluation of fine matrix computerized axial tomography (Emiscan) in the diagnosis of orbital space-occupying lesions. Brit. J. Radiol. 47, 747–751 (1974)

    Google Scholar 

  2. Baker, H.L., Kearns, T.P., Campbell, J.W., Henderson, J.W.: Computerized transaxial tomography in neuro-ophthalmology. Trans. Amer. Ophthal. Soc. 72, 49–64 (1974)

    Google Scholar 

  3. Bergström, K.: Computer tomography of the orbits. Acta radiol. Suppl. 346, 155–160 (1975)

    Google Scholar 

  4. Brismar, J., Davis, K.R., Dallow, R.L., Brismar, G.: Unilateral endocrine exophthalmos. Diagnostic problems in association with computed tomography. Neuroradiology 12, 21–24, (1976)

    Google Scholar 

  5. Daves, M.L., Loechel, W.E.: The interpretations of tomograms of the head. Springfield Ill.: Thomas 1962

    Google Scholar 

  6. Enzmann, D., Donaldson, S.S., Marshall, W.H., Kriss, J.P.: Computed tomography in orbital pseudotumour (Idiopathic orbital infammation). Radiology 120, 597–601 (1976)

    Google Scholar 

  7. Enzmann, D., Marshall, W.H., Rosenthal, A.R., Kriss, J.P.: Computed tomography in Graves' ophthalmopathy. Radiology 118, 615–620 (1976)

    Google Scholar 

  8. Gawler, J., Sanders, M.D., Bull, J.W.D., du Boulay, G., Marshall, J.: Computer assisted tomography in orbital disease. Brit. J. ophthal. 58, 571–587 (1974)

    Google Scholar 

  9. Godde-Jolly, D., Massin, M., Haut, J., Hamard, H., Chatellier, P., Cabanis, E. -A., Collard, M.: Apport de la tomographie axiale transverse avec calculateru intégré au diagnostique ophtalmologique et neuro-ophtalmologique. Bull. Soc. Ophtal. Fr. 75, S51–856 (1975)

    Google Scholar 

  10. Gyldensted, C., Lester, J., Fledelius, H.: Computed tomography of orbital lesions. A radiological study of 141 cases. Neuroradiology 13, 139–140 (1977)

    Google Scholar 

  11. Hammerschlag, S.B., Wolpert, S.M., Carter, B.L.: Computed coronal tomography. Radiology 120, 219–220 (1976)

    Google Scholar 

  12. Lampert, V.L., Zelch, J.V., Cohen, D.N.: Computed tomography of the orbits. Radiology 113, 351–354 (1974)

    Google Scholar 

  13. Michotey, P., Moseley, I.F., Aubin, M.L., Mouly, A., Farnarier, Ph., Sanders, M.D., Aron, D., Doyon, D.: Apport de la tomographie axiale commandée par ordinateur en ophtalmologie. J. Neurorad. 3, 257–276 (1976)

    Google Scholar 

  14. Momose, K.J., New, P.F.J., Grove, Jr., A.S., Scott, W.R.: The use of computed tomography in ophthalmology. Radiology 115, 361–368 (1975)

    Google Scholar 

  15. Mortelmans, L.L., Balériaux-Waha, D., Dupont, M.G., Jeanmart, L., Potvliege, R.: The use of computerized tomography in neuro-ophthalmology. Clinical computed tomography. Head and trunk. Berlin, Heidelberg, New York: Springer (To be published)

  16. Nover, A., Schmitt, J., Wende, S., Aulich, A.: Computertomographie in der Ophthalmologie. Klin. Mbl. Augenheilk. 168, 461–467 (1976)

    Google Scholar 

  17. ostertag, Ch.B., Unsold, R., Mundinger, F.: Computerized tomography in neuro-ophthalmology. In: Cranial computerized tomography (eds. W. Lanksch, E. Kazner), pp. 202–206. Berlin, Heidelberg, New York: Springer 1976

    Google Scholar 

  18. Sanders, M.D., Gawler, J.: Computerized tomographic scanning (EMI scan) in neuro-ophthalmology. Trans. Ophthal. Soc. U. K. 95, 237–245 (1975)

    Google Scholar 

  19. Sobotta, J., Becher, H.: Atlas der Anatomie des Menschen (Teil 3). München, Berlin: Urban und Schwarzenberg 1962

    Google Scholar 

  20. van Damme, W., Kosmann, P., Wackenheim, C.: A standardized method for computed tomography of the orbits. Neuroradiology 13, 139–140 (1977)

    Google Scholar 

  21. Wackenheim, A., van Damme, W., Kosmann, P., Bittighoffer, B.: Computed tomography in ophthalmology. Density changes with orbital lesions. Neuroradiology 13, 135–138 (1977)

    Google Scholar 

  22. Weinstein, M.A., Berlin Jr., A.J., Duchesneau, P.M.: High resolution computed tomography of the orbit with the Ohio-Nuclear Delta Head Scanner. Amer. J. Roentgenol. 127, 175–177 (1976)

    Google Scholar 

  23. Wende, S., Aulich, A., Lange, S., Lanksch, W., Schmitt, E.J.: Computerized tomography in diseases of the orbital region. In: Cranial computerized tomography. (eds. W. Lanksch, E. Kazner), pp. 207–211. Berlin, Heidelberg, New York: Springer 1976

    Google Scholar 

  24. Wende, S., Aulich, A., Nover, A., Lanksch, W., Kazner, E., Steinhoff, H., Meese, W., Lange, S., Grumme, T.: Computed tomography of orbital lesions. A cooperative study of 210 cases. Neuroradiology 13, 123–134 (1977)

    Google Scholar 

  25. Wolf, B.S., Nakagawa, H., Staulcup, P.H.: Feasibility of coronal views in computed tomography of the head. Radiology 120, 219–220 (1976)

    Google Scholar 

  26. Wollensak, J., Bleckmann, H., Lange, S., Grumme, T.: Computertomographie des Auges und der Orbita. Klin. Mbl. Augenheilk. 168, 467–475 (1976)

    Google Scholar 

  27. Wright, J.E., Lloyd, G.A.S., Ambrose, J.: Computerized axial tomography in the detection of orbital space-occupying lesions. Amer. J. Ophthal. 80, 78–84 (1975)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Balériaux-Waha, D., Mortelmans, L.L., Dupont, M.G. et al. The use of coronal scans for computed tomography of the orbits. Neuroradiology 14, 89–96 (1977). https://doi.org/10.1007/BF00339966

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00339966

Key-words

Navigation