Skip to main content
Log in

Cervical myelography with a watersoluble contrast medium (Metrizamide)

Myelographie cervicale avec un produit de contraste hydrosoluble (Metrizamide)

Zervikale Myelographie mit einem wasserlöslichen Kontrastmittel (Metrizamide). Vorläufiger Bericht mit besonderer Berücksichtigung der technischen Gesichtspunkte

A preliminary clinical report with special reference to technical aspects

  • Originals
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

Fifteen cervical myelographies were carried out with the nonionic watersoluble contrast medium metrizamide. The medium was injected by a lateral puncture between the laminae of the first and second cervical vertebrae. The quality of the radiographs was good. Minor, insignificant side effects were observed in a few patients, but neither the puncture nor the contrast medium caused any serious complications.

Résumé

Quinze myélographies cervicales ont été réalisées à l'aide de métrizamide, produit de contraste hydrosoluble non-ionique. Le produit fut injecté par ponction latérale entre les lames de la première et de la deuxième vertèbre cervicale. La qualité des radiographi était bonne. Des effects secondaires mineurs, non significatifs furent observés chez quelques malades mais ni la ponction ni le produit de contraste ne furent à l'origine de complications sérieuses.

Zusammenfassung

15 zervikale Myelographien wurden mit dem wasserlöslichen Kontrastmittel Metrizamide (Amipaque “Nyco”) durchgeführt. Dabei wurde das Kontrastmittel durch laterale Punktion des Zervikalkanals injiziert. Die gute Qualität des Röntgen-Kontrastes wird hervorgehoben. Bei einigen Patienten wurden geringe nebenwirkungen beobachtet. Keine ernsthaften Komplikationen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Metrizamide, a non-ionic water-soluble contrast medium. Experimental and preliminary clinical investigations. Acta radiol. (Suppl.) 335, 1973

  2. Gonsette, R. E.: Metrizamide as contrast medium for myelography and ventriculography. Preliminary clinical experiences. Acta radiol. (Suppl.) 335, 346–358 (1973)

    Google Scholar 

  3. Heinz, E. R., Goldman, R. L.: The role of gas myelography in neuroradiologic diagnosis. Comments on a new and simple technique. Radiology 102, 629–634 (1972)

    Google Scholar 

  4. Hindmarsh, T.: Methiodal sodium and metrizamide in lumbar myelography. Acta radiol. (Suppl.) 335, 359–366 (1973)

    Google Scholar 

  5. Hindmarsh, T.: Myelography with a non-ionic watersoluble contrast medium (metrizamide). Doctoral thesis, Stockholm 1974

  6. Mullan, S., Harper, P. V., hekmatpanah, J., Torres, H., Dobben, G.: Percutaneous interruption of spinalpain tracts by means of a Strontium90 needle. J. Neurosurg. 20, 931–939 (1963)

    Google Scholar 

  7. Rosomoff, H. L., Carroll, F., Brown, J., Sheptak, P.: Percutaneous radiofrequency cervical cordotomy: Technique. J. Neurosurg. 23, 639–644 (1965)

    Google Scholar 

  8. Skalpe, I. O., Torbergsen, T., Amundsen, P., Presthus, J.: Lumbar myelography with metrizamide. Acta radiol. (Suppl.) 335, 367–379 (1973)

    Google Scholar 

  9. Skalpe, I. O., Amundsen, P.: Lumbar radiculography with metrizamide, a non-ionic water-soluble contrast medium. Radiology (in press)

  10. Skalpe, I. O., Torvik, A.: The toxicity of metrizamide and meglumine iocarmate in the spinal subarachnoid space. An experimental study in rats with special reference to longterm effects. Invest. Radiol. (in press)

  11. Sortland, O.: Personal communication 1974

  12. Svare, A., Talle, K.: Lumbar myelography with metrizamide. An evaluation of 15 cases. Acta radiol. (Suppl.) 335, 387–390 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Amundsen, P., Skalpe, I.O. Cervical myelography with a watersoluble contrast medium (Metrizamide). Neuroradiology 8, 209–212 (1975). https://doi.org/10.1007/BF00337653

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00337653

Keywords

Navigation