Skip to main content
Log in

A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density

  • Originals
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

Computer-assisted methods of CT brain scan analysis offer considerable advantages over visual inspection, particularly in research; and several semi-automated methods are currently available. A new computer-assisted program is presented which provides fully automated processing of CT brain scans, depending on “anatomical knowledge” of where cerebrospinal fluid (CSF)-containing spaces are likely to lie. After identifying these regions of interest quantitative estimates are then provided of CSF content in each slice in cisterns, ventricles, Sylvian fissure and interhemispheric fissure. Separate measures are also provided of mean brain density in each slice. These estimates can be summated to provide total ventricular and total brain volumes. The program shows a high correlation with measures derived from mechanical planimetry and visual grading procedures, also when tested against a phantom brain of known ventricular volume. The advantages and limitations of the present program are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Weinberger DR, Bigelow LB, Kleinman JE, Klein ST, Rosenblatt JE, Wyatt RJ (1979) Lateral ventricular enlargement in chronic schizophrenia. Arch Gen Psychiatry 36:735–739

    Google Scholar 

  2. Andreasen NC, Smith MR, Jacoby CG, Dennert JW, Olsen SA (1982) Ventricular enlargement in schizophrenia: definition and prevalence. Am J Psychiatry 139:292–296

    Google Scholar 

  3. Naguib M, Levy R (1982) Prediction of outcome in senile dementia — a computed tomography study. Br J Psychiatry 140: 263–267

    Google Scholar 

  4. Ron MA, Acker W, Shaw GK, Lishman WA (1982) Computerised tomography of the brain in chronic alcoholics: a survey and follow-up study. Brain 105:497–514

    Google Scholar 

  5. Ron MA (1983) The alcoholic brain: CT scan and psychological findings. Psychological Med [Monogr Suppl] 3

  6. Penn RD, Belanger MG, Yasnoff WA (1978) Ventricular volume in man computed from CAT scans. Ann Neurol 3: 216–223

    Google Scholar 

  7. Sager WD, Gell G, Ladurner G, Ascher PW (1978) Calculation of cerebral tissue and cerebrospinal fluid space volumes from computer tomograms. Neuroradiology 16:176–178

    Google Scholar 

  8. Hacker H, Artmann H (1978) The calculation of CSF spaces in CT. Neuroradiology 16:190–192

    Google Scholar 

  9. Reveley AM, Reveley MA, Murray RM (1984) Cerebral ventricular enlargement in non-genetic schizophrenia: a controlled twin study. Br J Psychiatry 144:89–93

    Google Scholar 

  10. Walser RL, Ackerman LV (1977) Determination of volume from computerised tomograms: finding the volume of fluidfilled brain cavities. J Comput Assist Tomogr 1:117–130

    Google Scholar 

  11. Heinrich G, Mai N, Backmund H (1979) Preprocessing in computed tomography picture analysis: a “bone-deleting” algorithm. J Comput Assist Tomogr 3:379–384

    Google Scholar 

  12. Keller JM, Edwards FM, Rundle R (1981) Automatic outlining of regions on CT scans. J Comput Assist Tomogr 5: 240–265

    Google Scholar 

  13. Jernigan TL, Zatz LM, Naeser MA (1979) Semiautomated methods for quantitating CSF volume on cranial computed tomography. Radiology 132:463–466

    Google Scholar 

  14. Zatz LM, Jernigan TL, Ahamuda AJ Jr (1982) Changes on computed cranial tomography with aging: intracranial fluid volume. Am J Neuroradiol 3:1–11

    Google Scholar 

  15. Synek V, Reuben JR (1976) The ventricular-brain ratio using planimetric measurement of EMI scans. Br J Radiol 49: 233–237

    Google Scholar 

  16. Lishman WA (1981) Cerebral disorder in alcoholism: syndromes of impairment. Shorvon Memorial Lecture. Brain 104: 1–20

    Google Scholar 

  17. Reveley MA (1985) Ventricular enlargement in schizophrenia: the validity of computerised tomographic finding. Br J Psychiatry 147:233–240

    Google Scholar 

  18. Jacobson RR, Turner SW, Baldy RE, Lishman WA (1985) Densitometric analysis of CT scans: important sources of artefact. Psychol Med 15:879–889

    Google Scholar 

  19. Williams G, Bydder GM, Kreel L (1980) The validity and use of computed tomography attenuation values. Br Med Bull 36: 279–287

    Google Scholar 

  20. Brooks RA, Keller MR, O'Connor CM, Sheridan WT (1980) Progress towards quantitative computed tomography. IEEE Trans Nucl Sci NS 27:1121–1127

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work was supported by grants from the Medical Research Council

Rights and permissions

Reprints and permissions

About this article

Cite this article

Baldy, R.E., Brindley, G.S., Ewusi-Mensah, I. et al. A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density. Neuroradiology 28, 109–117 (1986). https://doi.org/10.1007/BF00327881

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00327881

Key words

Navigation