Skip to main content
Log in

A method of stereotaxic localization adopted for conventional and digital radiography

  • Originals
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not how to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or diagnostic stereotaxic devices.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Laitinen L (1971) A new stereoencephalotome. Zentralbl Neurochir 32: 67–73

    Google Scholar 

  2. Leksell L (1971) Stereotaxis and radiosurgery. An operative system. Ch. C Thomas, Springfield

    Google Scholar 

  3. Leksell L, Jernberg B (1980) Stereotaxis and tomography. Acta Neurochir 52:1–7

    Google Scholar 

  4. Riechert T, Mundinger F (1955) Beschreibung und anwendung eines zielgerätes für stereotaktische hirnoperationen. (II. Modell). Acta Neurochir [Suppl] 3:308–337

    Google Scholar 

  5. Spiegel EA, Wycis HT (1956) Studies in stereoencephalography. Am J Roentgenol 76:311–314

    Google Scholar 

  6. Talairach J, Ruggiero G, David M (1956) The roentgenologic contribution to stereotaxic investigations of the brain and its practical application in pathologic conditions. Acta Radiol 46: 390–406

    Google Scholar 

  7. Bergström M, Greitz T, Steiner L (1980) An approach to stereotaxic radiography. Acta Neurochir 54:157–165

    Google Scholar 

  8. Alberts WW (1961) Simple graphic stereotaxic localization. J Neurosurg 18:561–562

    Google Scholar 

  9. Colombo F, Angrilli F, Zanardo A, Pinna V, Alexandre A, Benedetti A (1982) A universal method to employ CT scanner spatial information in stereotactic surgery. Appl Neurophysiol 45:352–364

    Google Scholar 

  10. Seitzer D, Fröder M, Schäfer H, Dieckmann G (1980) Ein kompaktes tischrechnersystem zur zielpunktsberechnung in der stereotaktischen neurochirugie. Neurochirugia 23:62–66

    Google Scholar 

  11. Greitz T, Bergström M, Boethius J, Kingsley D, Ribbe T (1980) Head fixation system for integration of radiodiagnostic and therapeutic procedures. Neuroradiology 19:1–6

    Google Scholar 

  12. Kingsley D, Bergström M, Berggren B-M (1980) A critical evaluation of two methods of head fixation. Neuroradiology 19:7–12

    Google Scholar 

  13. Bergström M, Greitz T (1976) Stereotaxic computed tomography. Am J Roentgenol 127:167–170

    Google Scholar 

  14. Boethius J, Bergström M, Greitz T (1980) Stereotaxic computerized tomography with a GE 8800 scanner. J Neurosurg 52: 794–800

    Google Scholar 

  15. Boethius J, Bergström M, Greitz T, Ribbe T (1980) CT localization in stereotactic surgery. Appl Neurophys 43:164–169

    Google Scholar 

  16. Greitz T, Bergström M (1981) Stereotactic computed tomography of the head. In: Newton TH, Potts DG (eds) Radiology of the skull and brain, vol 5. Mosby, St. Louis, pp 4286–4296

    Google Scholar 

  17. Lewander R, Bergström M, Boethius J, Collins VP, Edner G, Greitz T, Willems J (1978) Stereotactic computer tomography for biopsy of gliomas. Acta Radiol Diagn 19:867–888

    Google Scholar 

  18. Bergström M, Boethius J, Eriksson L, Greitz T, Ribbe T, Widen L (1981) Head fixation device for reproducible position alignment in transmission CT and positron emission tomography. J Comput Assist Tomogr 5:136–141

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bergström, M., Greitz, T. & Ribbe, T. A method of stereotaxic localization adopted for conventional and digital radiography. Neuroradiology 28, 100–104 (1986). https://doi.org/10.1007/BF00327879

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00327879

Key words

Navigation