Abstract
The determination of mercury in the presence of Cu, Pb, Ag, Au, Pt, Pd, Se and As by cold vapor atomic absorption spectrometry was studied. Sodium tetrahydroborate(III) was used as a reducing agent. All the elements examined except arsenic exhibited strong interferences. A solution of 1,10-phenanthroline and thiosemicarbazide in 1.5% HCl solution was used as a masking agent. A highly effective reduction of interference by Cu, Ag, Au, Pt, Pd and Se was achieved. The results obtained were applied to the determination of mercury in a copper concentrate.
References
Poluektov NS, Vitkun RA (1963) Z Anal Khim 18:33
Poluektov NS, Vitkun RA, Zelynkova YV (1964) Z Anal Khim 19:873
Hatch WR, Ott WL (1968) Anal Chem 40:2085
Lopez-Escobar L, Hume DN (1973) Anal Lett 6:343
Toffaletti J, Savory J (1975) Anal Chem 47:2091
Ure AM (1975) Anal Chim Acta 76:1
Linstead G (1970) Analyst 95:264
Ure AM, Shand CA (1974) Anal Chim Acta 72:63
Rooney RC (1976) Analyst 101:678
Bernth N, Vendelbo K (1984) Analyst 109:309
Yamamoto Y, Kumamaru T, Shiraki A (1978) Fresenius Z Anal Chem 292:273
Kaiser G, Götz D, Tölg G, Knapp G, Maichin B, Spitzy H (1978) Fresenius Z Anal Chem 291:278
Welz B, Schubert-Jacobs M (1988) Fresenius Z Anal Chem 331:324
Pratt LK, Elrick KA (1987) At Spectrosc 8:170
Kuldvere A (1988) Analyst 113:277
Kirkbright GF, Taddia M (1978) Anal Chim Acta 100:145
Kuldvere A (1990) Analyst 115:559
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Szmyd, E., Baranowska, I. Elimination of interferences from Cu, Pb, Ag, Au, Pt, Pd and Se in the determination of mercury by CVAAS using sodium tetrahydroborate(III) reduction in copper concentrates. Fresenius J Anal Chem 350, 178–180 (1994). https://doi.org/10.1007/BF00323183
Received:
Accepted:
Issue Date: