Summary
Lithium was determined in two BCR Candidate Reference Materials 303 and 304 by Isotope Dilution Mass Spectrometry using the state-of-the-art performance of isotope-specific methods gained during previous certifications of 6LiF reference targets used for the determination of the neutron lifetime [1]. After reconstitution of the serum, four aliquots of each of the two candidate materials from four different bottles were spiked with a previously characterized enriched 6Li spike [2] which is now available as CBNM IRM-615 and has a certified 6Li/7 Li ratio of 21.78±0.12 and a certified lithium concentration of 4.001±0.028 μmol/g solution. The serum aliquots were digested in an HNO3/H2O2 mixture and after evaporation of the acid, the lithium was separated on a cation exchange column, eluted with 0.3 mol/L HCl and used as LiCl for mass spectrometric measurement on an NBS type thermal ionization mass spectrometer. Similarly an unknown sample BCR X, provided by BCR to check the performance of the certifying laboratories, was analyzed. In addition the chemical preparation method was controlled by assaying NBS (NIST) SRM 909. The chemical blank was determined by IDMS using 6Li enriched CBNM IRM-615. The measurements were corrected for isotopic fractionation using the Isotopic Reference Material CBNM IRM-016 chemically prepared in the same way as the samples. The CRM samples as well as the BCR X sample and the NBS SRM 909 were also analyzed for isotopic composition to verify whether they had indeed natural isotopic composition. The final results have an overall uncertainty of 1.2 and 1.5%, respectively. This overall uncertainty (on a 2s basis or an estimate thereof) takes into account all uncertainty contributions of statistical as well as of systematic nature (uncertainties on used reference materials, density and blank determinations). The final results compare favorably with the values proposed by BCR for certification, but have a smaller (better) uncertainty: CRM 303: (0.517 4±0.005 7) mmol/L, CRM 304: (0.987±0.014) mmol/L
Similar content being viewed by others
References
Lamberty A, De Bièvre P (1991) Int J Mass Spectrom Ion Proc 108:189–198
Lamberty A, Verbruggen A, Hendrickx F, De Bièvre P (1992) Int J Mass Spectrom Ion Proc 113:223–232
Schou M, (1976) Ann Rev Pharmacol 16:231–243
Bencze K (1989) Fresenius Z Anal Chem 334:707–708
Michiels E, De Bièvre P (1983) Int J Mass Spectrom Ion Phys 49:265–274
Lamberty A, De Bièvre P (1988) Int J Mass Spectrom Ion Proc 83:135–145
BCR - private communication
Addition to Report EUR 10627 EN (1986)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lamberty, A., De Bièvre, P. CBNM - determination of Li in BCR reference materials RM 303 and RM 304 lyophilized serum by isotope dilution mass spectrometry (IDMS). Fresenius J Anal Chem 345, 330–334 (1993). https://doi.org/10.1007/BF00322624
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00322624